rcft12vStatus

1.3.6.1.4.1.8886.2.1.3.1.1.4

Description

Êä³öµçѹÊÇ12·üµÄµçԴ״̬(1:Õý³£,2:²»Õý³£). The value of this object indicates the 12v-output of the power is normal or not. 1: normal 2: abnormal

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.8886.2.1.3.1.1 (rcftPowerEntry)
Node code
4
Node name
rcft12vStatus
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.8886.2.1.3.1.1.4
URN notation
urn:oid:1.3.6.1.4.1.8886.2.1.3.1.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 8886 2 1 3 1 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft12vStatus(4)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/8886/2/1/3/1/1/4
  • /ISO/Identified-Organization/6/1/4/1/8886/2/1/3/1/1/4
  • /ISO/3/6/1/4/1/8886/2/1/3/1/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/enterprise/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/enterprise/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/enterprises/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/enterprises/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/enterprises/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/identified-organization/dod/internet/private/vendor-objects/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/org/dod/internet/private/enterprise/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/org/dod/internet/private/enterprise/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/org/dod/internet/private/enterprise/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • /iso/org/dod/internet/private/enterprises/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft12vStatus
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1normal
2abnormal

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In RAISECOM-RCFT-MIB, the row index consists of these components in order:

  1. rcftChassisIndex (INTEGER): one numeric subidentifier for the non-negative value.
  2. rcftPowerIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.8886.2.1.3.1.1.4.<rcftChassisIndex>.<rcftPowerIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.8886.2.1.3.1.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

rcft12vStatus OBJECT-TYPE
        SYNTAX INTEGER
        {   
            normal(1),
            abnormal(2)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        " 
          Êä³öµçѹÊÇ12·üµÄµçԴ״̬(1:Õý³£,2:²»Õý³£).    
          The value of this object indicates the 12v-output of the power is normal or not. 
          1: normal
          2: abnormal 
        "
        ::= {rcftPowerEntry 4}

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Êä³öµçѹÊÇ12·üµÄµçԴ״̬(1:Õý³£,2:²»Õý³£). The value of this object indicates the 12v-output of the power is normal or not. 1: normal 2: abnormal

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

rcft12vStatus · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rcft12vStatus

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rcft12vStatus",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "normal",
    "(",
    "1",
    ")",
    ",",
    "abnormal",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\" Êä³öµçѹÊÇ12·üµÄµçԴ״̬(1:Õý³£,2:²»Õý³£). The value of this object indicates the 12v-output of the power is normal or not. 1: normal 2: abnormal \"",
    "::=",
    "{",
    "rcftPowerEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "normal",
            1
          ],
          [
            "abnormal",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Êä³öµçѹÊÇ12·üµÄµçԴ״̬(1:Õý³£,2:²»Õý³£). The value of this object indicates the 12v-output of the power is normal or not. 1: normal 2: abnormal"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.8886)

Gao Lei

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.8886.2.1.3.1.1.1 rcftPowerIndex00
1.3.6.1.4.1.8886.2.1.3.1.1.2 rcftPowerExist00
1.3.6.1.4.1.8886.2.1.3.1.1.3 rcft5vStatus00
1.3.6.1.4.1.8886.2.1.3.1.1.5 rcft5vAC00
1.3.6.1.4.1.8886.2.1.3.1.1.6 rcft12vAC00