OID reference

rcft5vAC

1.3.6.1.4.1.8886.2.1.3.1.1.5

Description

5·üµçÔ´¹©µç״̬(1:220½»Á÷,2:-48VÖ±Á÷). Chassis power-supply mode: 1: AC 2: DC

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.8886.2.1.3.1.1 (rcftPowerEntry)
Node code
5
Node name
rcft5vAC
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.8886.2.1.3.1.1.5
URN notation
urn:oid:1.3.6.1.4.1.8886.2.1.3.1.1.5
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 8886 2 1 3 1 1 5}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) raisecom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) raiseCom(8886) rc002(2) rcftMibObjects(1) rcftPower(3) rcftPowerTable(1) rcftPowerEntry(1) rcft5vAC(5)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/8886/2/1/3/1/1/5
  • /ISO/Identified-Organization/6/1/4/1/8886/2/1/3/1/1/5
  • /ISO/3/6/1/4/1/8886/2/1/3/1/1/5
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/enterprise/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/enterprise/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/enterprises/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/enterprises/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/enterprises/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/vendor-objects/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/vendor-objects/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/identified-organization/dod/internet/private/vendor-objects/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/org/dod/internet/private/enterprise/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/org/dod/internet/private/enterprise/raisecom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/org/dod/internet/private/enterprise/raiseCom/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • /iso/org/dod/internet/private/enterprises/8886/rc002/rcftMibObjects/rcftPower/rcftPowerTable/rcftPowerEntry/rcft5vAC
  • Additional combinations skipped.

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

ValueName
1ac
2dc

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In RAISECOM-RCFT-MIB, the row index consists of these components in order:

  1. rcftChassisIndex (INTEGER): one numeric subidentifier for the non-negative value.
  2. rcftPowerIndex (INTEGER): one numeric subidentifier for the non-negative value.

An instance has the form .1.3.6.1.4.1.8886.2.1.3.1.1.5.<rcftChassisIndex>.<rcftPowerIndex>. Use values present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.8886.2.1.3.1.1.5

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

The displayed source records contain one distinct definition. Compare its source records.

rcft5vAC OBJECT-TYPE
        SYNTAX INTEGER
        {   
            ac(1),
            dc(2)
        }
        MAX-ACCESS read-only
        STATUS current
        DESCRIPTION
        " 5·üµçÔ´¹©µç״̬(1:220½»Á÷,2:-48VÖ±Á÷). 
          Chassis power-supply mode:
           1: AC
           2: DC
        "
        ::= {rcftPowerEntry 5}

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

5·üµçÔ´¹©µç״̬(1:220½»Á÷,2:-48VÖ±Á÷). Chassis power-supply mode: 1: AC 2: DC

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

1 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

rcft5vAC · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: rcft5vAC

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rcft5vAC",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "ac",
    "(",
    "1",
    ")",
    ",",
    "dc",
    "(",
    "2",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\" 5·üµçÔ´¹©µç״̬(1:220½»Á÷,2:-48VÖ±Á÷). Chassis power-supply mode: 1: AC 2: DC \"",
    "::=",
    "{",
    "rcftPowerEntry",
    "5",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "ac",
            1
          ],
          [
            "dc",
            2
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "5·üµçÔ´¹©µç״̬(1:220½»Á÷,2:-48VÖ±Á÷). Chassis power-supply mode: 1: AC 2: DC"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.8886)

Gao Lei

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.8886.2.1.3.1.1.1 rcftPowerIndex00
1.3.6.1.4.1.8886.2.1.3.1.1.2 rcftPowerExist00
1.3.6.1.4.1.8886.2.1.3.1.1.3 rcft5vStatus00
1.3.6.1.4.1.8886.2.1.3.1.1.4 rcft12vStatus00
1.3.6.1.4.1.8886.2.1.3.1.1.6 rcft12vAC00