OID reference

rlPhyTestGetUnits

1.3.6.1.4.1.89.90.1.2.1.4

Description

The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diag…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.89.90.1.2.1 (rlPhyTestGetEntry)
Node code
4
Node name
rlPhyTestGetUnits
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.89.90.1.2.1.4
URN notation
urn:oid:1.3.6.1.4.1.89.90.1.2.1.4
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 89 90 1 2 1 4}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) enterprises(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
  • {iso(1) iso-organization(3) dod(6) internet(1) private(4) vendor-objects(1) rnd(89) rlPhy(90) rlPhyTest(1) rlPhyTestGetTable(2) rlPhyTestGetEntry(1) rlPhyTestGetUnits(4)}
OID-IRI notation
  • /1/3/6/1/4/1/89/90/1/2/1/4
  • /ISO/Identified-Organization/6/1/4/1/89/90/1/2/1/4
  • /ISO/3/6/1/4/1/89/90/1/2/1/4
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/enterprises/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/identified-organization/dod/internet/private/vendor-objects/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/org/dod/internet/private/enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/org/dod/internet/private/enterprises/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/org/dod/internet/private/ldap-enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/org/dod/internet/private/vendor-objects/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-identified-organization/dod/internet/private/enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-identified-organization/dod/internet/private/enterprises/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-identified-organization/dod/internet/private/ldap-enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-identified-organization/dod/internet/private/vendor-objects/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-organization/dod/internet/private/enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-organization/dod/internet/private/enterprises/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-organization/dod/internet/private/ldap-enterprise/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits
  • /iso/iso-organization/dod/internet/private/vendor-objects/rnd/rlPhy/rlPhyTest/rlPhyTestGetTable/rlPhyTestGetEntry/rlPhyTestGetUnits

SNMP properties

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Definitions may combine these properties differently.

Compare 2 source variants

Variant 1 — Netdisco MIB archive copies

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), NETGEAR official product and EOL MIB downloads, and others

Value type
INTEGER
Maximum access defined by MIB
read-only
Status in MIB
current

Enumerated values

Numbers refer to source variants above. Each value is shown only for variants that define it. Notes below names come from selected MIB definitions.

ValueName and source notesSource variants
1integer1, 2
2boolean1, 2
3downUP1, 2
4reverseNormal1, 2
5mdiMdix1, 2
6meter1, 2
7degree
Celsius
1, 2
8microVolt1, 2
9microOham1, 2
10microAmper1, 2
11microWatt1, 2
12millisecond1, 2
13alaskaPhyLength1, 2
14alaskaPhyStatus1, 2
15dbm1, 2
16decidbm1, 2
17milidbm1, 2
18abcd2
19nanosecond2

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.

Published row index: ifIndex, rlPhyTestGetType.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.89.90.1.2.1.4

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Product context

Documented MIB packages

The NETGEAR catalogue lists MIB files containing this definition with these product and release labels:

These are catalogue release labels, not necessarily MIB revisions. A MIB definition does not establish that a device implements it or permits access.

Available source records contain 3 distinct definitions; some records may not include a definition.

Show 3 published definitions

rlPhyTestGetUnits · current

rlPhyTestGetUnits   OBJECT-TYPE
   SYNTAX  INTEGER {
        integer(1),
        boolean(2),
        downUP(3),
        reverseNormal(4),
        mdiMdix(5),
        meter(6),
        degree(7),  -- Celsius
        microVolt(8),
        microOham(9),
        microAmper(10),
        microWatt(11),
        millisecond(12),
        alaskaPhyLength(13),
        alaskaPhyStatus(14),
        dbm(15),
        decidbm(16),
        milidbm(17)
            }
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The test result unit of measure. The units can be standard unit or special units
         that are designed for special test.

         The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
         less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).

         The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
         4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
   ::= { rlPhyTestGetEntry 4 }

rlPhyTestGetUnits · current

rlPhyTestGetUnits   OBJECT-TYPE
   SYNTAX  INTEGER {
        integer(1),
        boolean(2),
        downUP(3),
        reverseNormal(4),
        mdiMdix(5),
        meter(6),
        degree(7),  -- Celsius
        microVolt(8),
        microOham(9),
        microAmper(10),
        microWatt(11),
        millisecond(12),
        alaskaPhyLength(13),
        alaskaPhyStatus(14),
        dbm(15),
        decidbm(16),
        milidbm(17),
        abcd(18),
        nanosecond(19)
            }
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The test result unit of measure. The units can be standard unit or special units
         that are designed for special test.

         The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
         less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).

         The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
         4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
   ::= { rlPhyTestGetEntry 4 }

rlPhyTestGetUnits · current

rlPhyTestGetUnits   OBJECT-TYPE
   SYNTAX  INTEGER {
        integer(1),
        boolean(2),
        downUP(3),
        reverseNormal(4),
        mdiMdix(5),
        meter(6),
        degree(7),  -- Celsius
        microVolt(8),
        microOham(9),
        microAmper(10),
        microWatt(11),
        millisecond(12),
        alaskaPhyLength(13),
        alaskaPhyStatus(14),
        dbm(15),
        decidbm(16),
        milidbm(17),
        abcd(18),
        nanosecond(19)
            }
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
        "The test result unit of measure. The units can be standard unit or special units
         that are designed for special test.

         The alaskaPhyLength unit is design for the VCT diagnostic and its values are:
         less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5).

         The alaskaPhyStatus unit is design for the VCT diagnostic and its values are:
         4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
   ::= { rlPhyTestGetEntry 4 }

Meaning

Descriptions

1 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)Dell MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copiesNETGEAR official product and EOL MIB downloads

See 2 matching source records

Evidence

Source records

2 records

Matching descriptions are grouped; open a group to compare definitions and supporting files.

Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Dell MIB copies (LibreNMS/Observium Community), and others2 records · 7 sources

Description 1

rlPhyTestGetUnits · currentNetdisco MIB archive copies1 source

Status in source: current.

Names: rlPhyTestGetUnits

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rlPhyTestGetUnits",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "integer",
    "(",
    "1",
    ")",
    ",",
    "boolean",
    "(",
    "2",
    ")",
    ",",
    "downUP",
    "(",
    "3",
    ")",
    ",",
    "reverseNormal",
    "(",
    "4",
    ")",
    ",",
    "mdiMdix",
    "(",
    "5",
    ")",
    ",",
    "meter",
    "(",
    "6",
    ")",
    ",",
    "degree",
    "(",
    "7",
    ")",
    ",",
    "microVolt",
    "(",
    "8",
    ")",
    ",",
    "microOham",
    "(",
    "9",
    ")",
    ",",
    "microAmper",
    "(",
    "10",
    ")",
    ",",
    "microWatt",
    "(",
    "11",
    ")",
    ",",
    "millisecond",
    "(",
    "12",
    ")",
    ",",
    "alaskaPhyLength",
    "(",
    "13",
    ")",
    ",",
    "alaskaPhyStatus",
    "(",
    "14",
    ")",
    ",",
    "dbm",
    "(",
    "15",
    ")",
    ",",
    "decidbm",
    "(",
    "16",
    ")",
    ",",
    "milidbm",
    "(",
    "17",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).\"",
    "::=",
    "{",
    "rlPhyTestGetEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "integer",
            1
          ],
          [
            "boolean",
            2
          ],
          [
            "downUP",
            3
          ],
          [
            "reverseNormal",
            4
          ],
          [
            "mdiMdix",
            5
          ],
          [
            "meter",
            6
          ],
          [
            "degree",
            7
          ],
          [
            "microVolt",
            8
          ],
          [
            "microOham",
            9
          ],
          [
            "microAmper",
            10
          ],
          [
            "microWatt",
            11
          ],
          [
            "millisecond",
            12
          ],
          [
            "alaskaPhyLength",
            13
          ],
          [
            "alaskaPhyStatus",
            14
          ],
          [
            "dbm",
            15
          ],
          [
            "decidbm",
            16
          ],
          [
            "milidbm",
            17
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
    ],
    null,
    null,
    null,
    null
  ]
}
rlPhyTestGetUnits · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community), Dell MIB copies (LibreNMS/Observium Community), and others6 sources

Status in source: current.

Names: rlPhyTestGetUnits

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rlPhyTestGetUnits",
    "OBJECT-TYPE",
    "SYNTAX",
    "INTEGER",
    "{",
    "integer",
    "(",
    "1",
    ")",
    ",",
    "boolean",
    "(",
    "2",
    ")",
    ",",
    "downUP",
    "(",
    "3",
    ")",
    ",",
    "reverseNormal",
    "(",
    "4",
    ")",
    ",",
    "mdiMdix",
    "(",
    "5",
    ")",
    ",",
    "meter",
    "(",
    "6",
    ")",
    ",",
    "degree",
    "(",
    "7",
    ")",
    ",",
    "microVolt",
    "(",
    "8",
    ")",
    ",",
    "microOham",
    "(",
    "9",
    ")",
    ",",
    "microAmper",
    "(",
    "10",
    ")",
    ",",
    "microWatt",
    "(",
    "11",
    ")",
    ",",
    "millisecond",
    "(",
    "12",
    ")",
    ",",
    "alaskaPhyLength",
    "(",
    "13",
    ")",
    ",",
    "alaskaPhyStatus",
    "(",
    "14",
    ")",
    ",",
    "dbm",
    "(",
    "15",
    ")",
    ",",
    "decidbm",
    "(",
    "16",
    ")",
    ",",
    "milidbm",
    "(",
    "17",
    ")",
    ",",
    "abcd",
    "(",
    "18",
    ")",
    ",",
    "nanosecond",
    "(",
    "19",
    ")",
    "}",
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7).\"",
    "::=",
    "{",
    "rlPhyTestGetEntry",
    "4",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "INTEGER",
      [
        "enumSpec",
        [
          [
            "integer",
            1
          ],
          [
            "boolean",
            2
          ],
          [
            "downUP",
            3
          ],
          [
            "reverseNormal",
            4
          ],
          [
            "mdiMdix",
            5
          ],
          [
            "meter",
            6
          ],
          [
            "degree",
            7
          ],
          [
            "microVolt",
            8
          ],
          [
            "microOham",
            9
          ],
          [
            "microAmper",
            10
          ],
          [
            "microWatt",
            11
          ],
          [
            "millisecond",
            12
          ],
          [
            "alaskaPhyLength",
            13
          ],
          [
            "alaskaPhyStatus",
            14
          ],
          [
            "dbm",
            15
          ],
          [
            "decidbm",
            16
          ],
          [
            "milidbm",
            17
          ],
          [
            "abcd",
            18
          ],
          [
            "nanosecond",
            19
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "The test result unit of measure. The units can be standard unit or special units that are designed for special test. The alaskaPhyLength unit is design for the VCT diagnostic and its values are: less_than_50M(1), 50-80M(2), 80-110M(3), 110-140M(4), more_than_140M(5). The alaskaPhyStatus unit is design for the VCT diagnostic and its values are: 4_pair_cable(1), 2_pair_cable(2), no_cable(3), open_cable(4), short_cable(5), bad_cable(6), impedance_mismatch(7)."
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.89)

Nethaniel Rina

Siblings (5)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.89.90.1.2.1.1 rlPhyTestGetType00
1.3.6.1.4.1.89.90.1.2.1.2 rlPhyTestGetStatus00
1.3.6.1.4.1.89.90.1.2.1.3 rlPhyTestGetResult00
1.3.6.1.4.1.89.90.1.2.1.5 rlPhyTestGetAlarm00
1.3.6.1.4.1.89.90.1.2.1.6 rlPhyTestGetTimeStamp00