Actual Aggregate Transmit Power Downstream. The total amount of transmit power delivered by the xTU-C at the U-C reference point, at the instant of measurement. It ranges from -310 to 310 units of 0.1 dBm (Physical values are -31 to 31 dBm). A value of 0x7FFFFFFF (2147483647) indicates the measurement is out of range to be represented. This object reflects the value of the parameter following the most recent DELT performed on the associated line. Once the DELT process is over, the parameter no longer changes until the row is deleted or a new DELT process is initiated.
OID reference
xdsl2SCStatusActAtp
1.3.6.1.4.1.890.1.5.12.48.60.2.3.1.1
Description
Actual Aggregate Transmit Power Downstream. The total amount of transmit power delivered by the xTU-C at the U-C reference point, at the instant of measurement. It ranges from -310 to 310 units of 0.1 dBm (Physical values are -31 to 31 dBm). A value of 0x7FFFFFFF (2147483647) indicates the measurement is out of range …
Identification
Identifier and names
- Parent
- 1.3.6.1.4.1.890.1.5.12.48.60.2.3.1 (xdsl2ExtSCStatusEntry)
- Node code
- 1
- Node name
- xdsl2SCStatusActAtp
- Category
- SNMP management object
- Numeric OID
- 1.3.6.1.4.1.890.1.5.12.48.60.2.3.1.1
- URN notation
- urn:oid:1.3.6.1.4.1.890.1.5.12.48.60.2.3.1.1
ASN.1, OID-IRI and named path variants
- ASN.1 notation
-
{1 3 6 1 4 1 890 1 5 12 48 60 2 3 1 1}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyxel(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) thermalSensorFailure(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55C(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) zyXEL(890) products(1) accessSwitch(5) vesSeries(12) ves1724-55c(48) vdsl2Ext(60) xdsl2ExtStatus(2) xdsl2ExtSCStatusTable(3) xdsl2ExtSCStatusEntry(1) xdsl2SCStatusActAtp(1)}
- Additional combinations skipped.
- OID-IRI notation
- /1/3/6/1/4/1/890/1/5/12/48/60/2/3/1/1
- /ISO/Identified-Organization/6/1/4/1/890/1/5/12/48/60/2/3/1/1
- /ISO/3/6/1/4/1/890/1/5/12/48/60/2/3/1/1
- Named path variants
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/thermalSensorFailure/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/products/accessSwitch/vesSeries/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/thermalSensorFailure/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/ZyXEL/Products/accessSwitch/vesSeries/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/thermalSensorFailure/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/products/accessSwitch/vesSeries/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/thermalSensorFailure/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55C/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- /iso/identified-organization/dod/internet/private/enterprise/zyxel/Products/accessSwitch/vesSeries/ves1724-55c/vdsl2Ext/xdsl2ExtStatus/xdsl2ExtSCStatusTable/xdsl2ExtSCStatusEntry/xdsl2SCStatusActAtp
- Additional combinations skipped.
SNMP properties
- Value type
- Integer32
- Units
- 0.1 dBm
- Maximum access defined by MIB
- read-only
- Status in MIB
- current
- Default value
- 2147483647
Using this OID with SNMP
At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition. The index encoding is not inferred here.
Published row index: ifIndex, xdsl2SCStatusDirection.
snmpwalk [connection options] DEVICE .1.3.6.1.4.1.890.1.5.12.48.60.2.3.1.1
Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.
Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.
Product context
Documented MIB packages
The Zyxel catalogue lists MIB packages containing this definition for these models:
A definition in a model's MIB package does not establish that the device implements it or permits access.
Published definition
The displayed source records contain one distinct definition. Compare its source records.
xdsl2SCStatusActAtp OBJECT-TYPE
SYNTAX Integer32 (-310..310 | 2147483647)
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual Aggregate Transmit Power Downstream.
The total amount of transmit power delivered by the xTU-C at
the U-C reference point, at the instant of measurement. It
ranges from -310 to 310 units of 0.1 dBm (Physical values are -31
to 31 dBm).
A value of 0x7FFFFFFF (2147483647) indicates the measurement is
out of range to be represented.
This object reflects the value of the parameter following the
most recent DELT performed on the associated line. Once the DELT
process is over, the parameter no longer changes until the row is
deleted or a new DELT process is initiated.
"
DEFVAL { 2147483647 }
::= { xdsl2ExtSCStatusEntry 1 }
Meaning
Descriptions
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Evidence
Source records
Matching descriptions are grouped; open a group to compare definitions and supporting files.
Records for description 1Zyxel official Download Library MIBs
xdsl2SCStatusActAtp · currentZyxel official Download Library MIBs
Status in source: current.
Names: xdsl2SCStatusActAtp
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"xdsl2SCStatusActAtp",
"OBJECT-TYPE",
"SYNTAX",
"Integer32",
"(",
"-",
"310",
".",
".",
"310",
"|",
"2147483647",
")",
"UNITS",
[
"literal",
"22302e312064426d22"
],
"MAX-ACCESS",
"read-only",
"STATUS",
"current",
"DESCRIPTION",
"\"Actual Aggregate Transmit Power Downstream. The total amount of transmit power delivered by the xTU-C at the U-C reference point, at the instant of measurement. It ranges from -310 to 310 units of 0.1 dBm (Physical values are -31 to 31 dBm). A value of 0x7FFFFFFF (2147483647) indicates the measurement is out of range to be represented. This object reflects the value of the parameter following the most recent DELT performed on the associated line. Once the DELT process is over, the parameter no longer changes until the row is deleted or a new DELT process is initiated. \"",
"DEFVAL",
"{",
"2147483647",
"}",
"::=",
"{",
"xdsl2ExtSCStatusEntry",
"1",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"Integer32",
[
"integerSubType",
[
[
-310,
310
],
[
2147483647
]
]
]
],
[
"UNITS",
"0.1 dBm"
],
[
"MaxAccessPart",
"read-only"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Actual Aggregate Transmit Power Downstream. The total amount of transmit power delivered by the xTU-C at the U-C reference point, at the instant of measurement. It ranges from -310 to 310 units of 0.1 dBm (Physical values are -31 to 31 dBm). A value of 0x7FFFFFFF (2147483647) indicates the measurement is out of range to be represented. This object reflects the value of the parameter following the most recent DELT performed on the associated line. Once the DELT process is over, the parameter no longer changes until the row is deleted or a new DELT process is initiated."
],
null,
null,
null,
[
"DEFVAL",
2147483647
]
]
}- Zyxel official Download Library MIBs
· Publisher's source file: VES1724-55C_2.mib
Module: ZYXEL-ves1724-55c-MIB
See published definition above
· Download VES1724-55C_2.mibModule imports
{'IF-MIB': ['InterfaceIndexOrZero', 'ifIndex'], 'IPV6-TC': ['Ipv6Address', 'Ipv6AddressPrefix'], 'SNMPv2-TC': ['RowStatus', 'DateAndTime', 'TruthValue', 'StorageType', 'MacAddress'], 'BRIDGE-MIB': ['dot1dBasePort', 'BridgeId', 'Timeout'], 'SNMPv2-SMI': ['OBJECT-TYPE', 'IpAddress', 'NOTIFICATION-TYPE'], 'RFC1155-SMI': ['enterprises'], 'RFC1213-MIB': ['DisplayString', 'sysObjectID'], 'P-BRIDGE-MIB': ['EnabledStatus'], 'Q-BRIDGE-MIB': ['PortList', 'dot1qVlanIndex'], 'VDSL-LINE-MIB': ['vdslLineConfProfileName', 'vdslLineAlarmConfProfileName', 'vdslPerf1DayIntervalNumber', 'vdslPhysSide', 'vdslPerfIntervalNumber'], 'VDSL2-LINE-MIB': ['xdsl2PMChHist1DInterval', 'xdsl2LineBand', 'xdsl2SCStatusSegment', 'xdsl2LineSegmentDirection', 'xdsl2LineSegment', 'xdsl2ChStatusUnit', 'xdsl2SCStatusDirection', 'xdsl2SCStatusBand', 'xdsl2PMLHist15MUnit', 'xdsl2PMLHist15MInterval', 'xdsl2PMLHist1DUnit', 'xdsl2PMLHist1DInterval', 'xdsl2PMChCurrUnit', 'xdsl2PMChHist15MUnit', 'xdsl2PMChHist15MInterval', 'xdsl2PMLCurrUnit', 'xdsl2PMChHist1DUnit', 'xdsl2LConfTempTemplateName', 'xdsl2LConfProfProfileName', 'xdsl2ChConfProfProfileName', 'xdsl2LAlarmConfTempTemplateName', 'xdsl2LineAlarmConfProfileName', 'xdsl2ChAlarmConfProfileName'], 'DISMAN-PING-MIB': ['OperationResponseStatus'], 'IEEE8021-CFM-MIB': ['Dot1agCfmMepId'], 'INET-ADDRESS-MIB': ['InetAddressType', 'InetAddress'], 'VDSL2-LINE-TC-MIB': ['Xdsl2RaMode', 'Xdsl2LineLdsf'], 'HC-PerfHist-TC-MIB': ['HCPerfIntervalThreshold', 'HCPerfTimeElapsed'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString']}
Registration