Status in source: current.
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"ontAction",
"OBJECT-TYPE",
"SYNTAX",
"INTEGER",
"{",
"idle",
"(",
"0",
")",
",",
"rebootOnt",
"(",
"1",
")",
",",
"checkUpgardeFW",
"(",
"2",
")",
",",
"upgradingFW",
"(",
"3",
")",
",",
"delAllConfig",
"(",
"4",
")",
",",
"downloadFile",
"(",
"5",
")",
",",
"uploadFile",
"(",
"6",
")",
",",
"switchImageRule",
"(",
"7",
")",
",",
"clearUpgradeStatus",
"(",
"8",
")",
"}",
"MAX-ACCESS",
"read-write",
"STATUS",
"current",
"DESCRIPTION",
"\"Setting this MIB with value below to request an action to occur for the ONU. 1 Reboot the ONU. 2 Perform a FW version check. If the current version mismatches with planned one, do FW upgrade if possible. 4 Delete all configuration stored in OLT related to the ONU. 5 Perform a file transfer. Download a file located in <ontFileTransferFileUri> with user name / password defined in <ontFileTransferUserName> and <ontFileTransferPassword> to the ONU and rename it to <ontFileTransferLocalFileName>. 6 Perform a file transfer. Upload a file <ontFileTransferLocalFileName> from the ONU to destination defined in <ontFileTransferFileUri> with user name / password defined in <ontFileTransferUserName> and <ontFileTransferPassword>. 7 Switch the ONU active/standby image rule and reboot. 8 Clear the ont upgrade status. This MIB returns following status to a get request. 0 This ONU is not doing any action above. 3 The FW upgrading is in progress.\"",
"::=",
"{",
"ontEntry",
"11",
"}"
],
"syntax_tree": [
[
"SimpleSyntax",
"INTEGER",
[
"enumSpec",
[
[
"idle",
0
],
[
"rebootOnt",
1
],
[
"checkUpgardeFW",
2
],
[
"upgradingFW",
3
],
[
"delAllConfig",
4
],
[
"downloadFile",
5
],
[
"uploadFile",
6
],
[
"switchImageRule",
7
],
[
"clearUpgradeStatus",
8
]
]
]
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"current"
],
[
"DESCRIPTION",
"Setting this MIB with value below to request an action to occur for the ONU. 1 Reboot the ONU. 2 Perform a FW version check. If the current version mismatches with planned one, do FW upgrade if possible. 4 Delete all configuration stored in OLT related to the ONU. 5 Perform a file transfer. Download a file located in <ontFileTransferFileUri> with user name / password defined in <ontFileTransferUserName> and <ontFileTransferPassword> to the ONU and rename it to <ontFileTransferLocalFileName>. 6 Perform a file transfer. Upload a file <ontFileTransferLocalFileName> from the ONU to destination defined in <ontFileTransferFileUri> with user name / password defined in <ontFileTransferUserName> and <ontFileTransferPassword>. 7 Switch the ONU active/standby image rule and reboot. 8 Clear the ont upgrade status. This MIB returns following status to a get request. 0 This ONU is not doing any action above. 3 The FW upgrading is in progress."
],
null,
null,
null,
null
]
}