OID reference

rttMonCtrlAdminFrequency

1.3.6.1.4.1.9.9.42.1.2.1.1.6

Description

Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which ha…

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9.9.42.1.2.1.1 (rttMonCtrlAdminEntry)
Node code
6
Node name
rttMonCtrlAdminFrequency
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9.9.42.1.2.1.1.6
URN notation
urn:oid:1.3.6.1.4.1.9.9.42.1.2.1.1.6
Type
OBJECT-TYPE
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9 9 42 1 2 1 1 6}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) ldap-enterprise(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) vendor-objects(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) ldap-enterprise(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) cisco(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • {iso(1) org(3) dod(6) internet(1) private(4) vendor-objects(1) me1200(9) ciscoMgmt(9) ciscoRttMonMIB(42) ciscoRttMonObjects(1) rttMonCtrl(2) rttMonCtrlAdminTable(1) rttMonCtrlAdminEntry(1) rttMonCtrlAdminFrequency(6)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9/9/42/1/2/1/1/6
  • /ISO/Identified-Organization/6/1/4/1/9/9/42/1/2/1/1/6
  • /ISO/3/6/1/4/1/9/9/42/1/2/1/1/6
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/enterprise/me1200/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/enterprise/Cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/enterprises/me1200/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/enterprises/Cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/me1200/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/ldap-enterprise/Cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/vendor-objects/cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/vendor-objects/me1200/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/identified-organization/dod/internet/private/vendor-objects/Cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/org/dod/internet/private/enterprise/cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/org/dod/internet/private/enterprise/me1200/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/org/dod/internet/private/enterprise/Cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • /iso/org/dod/internet/private/enterprises/cisco/ciscoMgmt/ciscoRttMonMIB/ciscoRttMonObjects/rttMonCtrl/rttMonCtrlAdminTable/rttMonCtrlAdminEntry/rttMonCtrlAdminFrequency
  • Additional combinations skipped.

SNMP properties

Value type
Integer32, INTEGER
Units
seconds
Maximum access defined by MIB
read-create, read-write
Status in MIB
current, mandatory
Default value
60

Definitions may combine these properties differently.

Compare 3 source variants

Variant 1 — Cisco, Cisco MIB copies (LibreNMS/Observium Community), and others

Value type
Integer32
Units
seconds
Maximum access defined by MIB
read-create
Status in MIB
current
Default value
60
Allowed ranges
0–604800

Variant 2 — Cisco SMIv1, MIBdepot

Value type
Integer32
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
60
Allowed ranges
0–604800

Variant 3 — Cisco SMIv1

Value type
INTEGER
Maximum access defined by MIB
read-write
Status in MIB
mandatory
Default value
60
Allowed ranges
0–604800

Using this OID with SNMP

At least one MIB declaration places this object in a table row. A value belongs to a row instance; its suffix depends on the row's INDEX or AUGMENTS definition.

In CISCO-RTTMON-MIB, the row index rttMonCtrlAdminIndex is declared as Integer32. A non-negative index value is encoded as one numeric subidentifier. An instance has the form .1.3.6.1.4.1.9.9.42.1.2.1.1.6.<rttMonCtrlAdminIndex>. Use an index value actually present on the device and permitted by its MIB. Other definitions can differ.

snmpwalk [connection options] DEVICE .1.3.6.1.4.1.9.9.42.1.2.1.1.6

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 4 distinct definitions; some records may not include a definition.

Show 4 published definitions

rttMonCtrlAdminFrequency · current

rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX          Integer32 (0..604800)
    UNITS           "seconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "Specifies the duration between initiating each RTT
        operation. 

        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.

        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. 

        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho' or 'pathJitter', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.

        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho' or 'pathJitter', the suggested value for this object
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target.

        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'dhcp', the minimum allowed value for this
               object is 10 seconds.  This restriction is due to
               protocol limitations described in RFC 2131."
    DEFVAL          { 60 } 
    ::= { rttMonCtrlAdminEntry 6 }

rttMonCtrlAdminFrequency · mandatory

rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX Integer32(0..604800)
--  Units
--    seconds
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Specifies the duration between initiating each RTT 
        operation. 
        
        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.
        
        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. 
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.
        
        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho', the suggested value for this object 
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target.
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'dhcp', the minimum allowed value for this
               object is 10 seconds.  This restriction is due to
               protocol limitations described in RFC 2131."
    DEFVAL { 60 }
    ::= { rttMonCtrlAdminEntry 6 }

rttMonCtrlAdminFrequency · mandatory

rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX Integer32(0..604800)
--  Units
--    seconds
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Specifies the duration between initiating each RTT 
        operation. 
        
        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.
        
        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. 
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.
        
        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho', the suggested value for this object 
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target.
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'dhcp', the minimum allowed value for this
               object is 10 seconds.  This restriction is due to
               protocol limitations described in RFC 2131."
    DEFVAL { 60 }
    ::= { rttMonCtrlAdminEntry 6 }

rttMonCtrlAdminFrequency · mandatory

rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX Integer32(0..604800)
--  Units
--    seconds
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Specifies the duration between initiating each RTT 
        operation. 
        
        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.
        
        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. An Example of this
        is when the RttMonRttType is 'echo' and the 
        RttMonProtocol is 'snaLU0EchoAppl'.
        
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.
        
        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho', the suggested value for this object 
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target."
    DEFVAL { 60 }
    ::= { rttMonCtrlAdminEntry 6 }

Meaning

Descriptions

4 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. NOTE: When the rttMonCtrlAdminRttType object is defined to be pathEcho, setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be pathEcho, the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target. NOTE: When the rttMonCtrlAdminRttType object is defined to be dhcp, the minimum allowed value for this object is 10 seconds. This restriction is due to protocol limitations described in RFC 2131.
Original text from OID Repository
rttMonCtrlAdminFrequency OBJECT-TYPE
SYNTAX Integer32 (0..604800)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Specifies the duration between initiating each RTT
operation.
This object cannot be set to a value which would be a
shorter duration than rttMonCtrlAdminTimeout.
When the RttMonRttType specifies an operation that is
synchronous in nature, it may happen that the next RTT
operation is blocked by a RTT operation which has not
yet completed. In this case, the value of a counter
(rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
incremented in lieu of initiating a RTT operation, and
the next attempt will occur at the next
rttMonCtrlAdminFrequency expiration.
NOTE: When the rttMonCtrlAdminRttType object is defined
to be pathEcho, setting this value to a small
value for your network size may cause an operation
attempt (or multiple attempts) to be started
before the previous operation has finished. In
this situation the rttMonStatsCollectBusies object
will be incremented in lieu of initiating a new
RTT operation, and the next attempt will occur at
the next rttMonCtrlAdminFrequency expiration.
When the rttMonCtrlAdminRttType object is defined
to be pathEcho, the suggested value for this object
is greater than rttMonCtrlAdminTimeout times the
maximum number of expected hops to the target.
NOTE: When the rttMonCtrlAdminRttType object is defined
to be dhcp, the minimum allowed value for this
object is 10 seconds. This restriction is due to
protocol limitations described in RFC 2131."
DEFVAL { 60 }
Sources for this description

OID Repository

View at oid-base.com
Automatically extracted from Cisco "SNMP v2 MIBs".

Description 2

Specifies the duration between initiating each RTT
operation.

This object cannot be set to a value which would be a
shorter duration than rttMonCtrlAdminTimeout.

When the RttMonRttType specifies an operation that is
synchronous in nature, it may happen that the next RTT
operation is blocked by a RTT operation which has not
yet completed. In this case, the value of a counter
(rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
incremented in lieu of initiating a RTT operation, and
the next attempt will occur at the next
rttMonCtrlAdminFrequency expiration.

NOTE: When the rttMonCtrlAdminRttType object is defined
to be 'pathEcho', setting this value to a small
value for your network size may cause an operation
attempt (or multiple attempts) to be started
before the previous operation has finished. In
this situation the rttMonStatsCollectBusies object
will be incremented in lieu of initiating a new
RTT operation, and the next attempt will occur at
the next rttMonCtrlAdminFrequency expiration.

When the rttMonCtrlAdminRttType object is defined
to be 'pathEcho', the suggested value for this object
is greater than rttMonCtrlAdminTimeout times the
maximum number of expected hops to the target.

NOTE: When the rttMonCtrlAdminRttType object is defined
to be 'dhcp', the minimum allowed value for this
object is 10 seconds. This restriction is due to
protocol limitations described in RFC 2131.
Sources for this description

Cisco SMIv1MIBdepot

See 1 matching source record

Circitor

Parsed from CISCO-RTTMON-MIB.mib · CISCO-RTTMON-MIB

Source file: Download CISCO-RTTMON-MIB.mib

Cisco

Source file: Download CISCO-RTTMON-MIB · Publisher's file

Vendor MIB copy from the LibreNMS archive. Cisco support.

Related source files and packages:

Description 3

Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho' or 'pathJitter', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho' or 'pathJitter', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'dhcp', the minimum allowed value for this object is 10 seconds. This restriction is due to protocol limitations described in RFC 2131.

Sources for this description

CiscoCisco MIB copies (LibreNMS/Observium Community)Netdisco MIB archive copies

See 1 matching source record

Description 4

Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. An Example of this is when the RttMonRttType is 'echo' and the RttMonProtocol is 'snaLU0EchoAppl'. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target.

Sources for this description

MIBdepot

See 1 matching source record

Evidence

Source records

3 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 3Cisco, Cisco MIB copies (LibreNMS/Observium Community), and others1 record · 3 sources

Description 3

rttMonCtrlAdminFrequency · currentCisco, Cisco MIB copies (LibreNMS/Observium Community), and others3 sources

Status in source: current.

Names: rttMonCtrlAdminFrequency

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rttMonCtrlAdminFrequency",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "604800",
    ")",
    "UNITS",
    [
      "literal",
      "227365636f6e647322"
    ],
    "MAX-ACCESS",
    "read-create",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho' or 'pathJitter', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho' or 'pathJitter', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'dhcp', the minimum allowed value for this object is 10 seconds. This restriction is due to protocol limitations described in RFC 2131.\"",
    "DEFVAL",
    "{",
    "60",
    "}",
    "::=",
    "{",
    "rttMonCtrlAdminEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            604800
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "seconds"
    ],
    [
      "MaxAccessPart",
      "read-create"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho' or 'pathJitter', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho' or 'pathJitter', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'dhcp', the minimum allowed value for this object is 10 seconds. This restriction is due to protocol limitations described in RFC 2131."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      60
    ]
  ]
}
  • Cisco · Publisher's source file: CISCO-RTTMON-MIB.my

    Module: CISCO-RTTMON-MIB

    See published definition above

    Module imports
    {'IF-MIB': ['InterfaceIndexOrZero'], 'CISCO-SMI': ['ciscoMgmt'], 'SNMPv2-TC': ['StorageType', 'DisplayString', 'TruthValue', 'RowStatus', 'TimeInterval', 'TimeStamp', 'MacAddress'], 'SNMPv2-SMI': ['MODULE-IDENTITY', 'OBJECT-TYPE', 'NOTIFICATION-TYPE', 'Integer32', 'Unsigned32', 'Counter32', 'Gauge32', 'TimeTicks'], 'SNMPv2-CONF': ['NOTIFICATION-GROUP', 'MODULE-COMPLIANCE', 'OBJECT-GROUP'], 'Q-BRIDGE-MIB': ['VlanId'], 'DIFFSERV-DSCP-TC': ['Dscp'], 'INET-ADDRESS-MIB': ['InetAddress', 'InetAddressType'], 'CISCO-QOS-PIB-MIB': ['QosLayer2Cos'], 'SNMP-FRAMEWORK-MIB': ['SnmpAdminString'], 'CISCO-ETHER-CFM-MIB': ['CfmMepid'], 'CISCO-RTTMON-TC-MIB': ['RttReset', 'RttMonOperation', 'RttResponseSense', 'RttMonRttType', 'RttMplsVpnMonRttType', 'RttMplsVpnMonLpdFailureSense', 'RttMplsVpnMonLpdGrpStatus', 'RttMonProtocol', 'RttMonCodecType', 'RttMonLSPPingReplyMode', 'RttMonTargetAddress', 'RttMonReactVar', 'RttMonScheduleStartType']}
    · Download CISCO-RTTMON-MIB.my
Records for description 2Cisco SMIv1, MIBdepot1 record · 2 sources

Description 2

rttMonCtrlAdminFrequency · mandatoryCisco SMIv1, MIBdepot2 sources

Status in source: mandatory.

Names: rttMonCtrlAdminFrequency

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rttMonCtrlAdminFrequency",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "604800",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'dhcp', the minimum allowed value for this object is 10 seconds. This restriction is due to protocol limitations described in RFC 2131.\"",
    "DEFVAL",
    "{",
    "60",
    "}",
    "::=",
    "{",
    "rttMonCtrlAdminEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            604800
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'dhcp', the minimum allowed value for this object is 10 seconds. This restriction is due to protocol limitations described in RFC 2131."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      60
    ]
  ]
}
Records for description 4MIBdepot1 record · 1 source

Description 4

rttMonCtrlAdminFrequency · mandatoryMIBdepot1 source

Status in source: mandatory.

Names: rttMonCtrlAdminFrequency

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "rttMonCtrlAdminFrequency",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "604800",
    ")",
    "ACCESS",
    "read-write",
    "STATUS",
    "mandatory",
    "DESCRIPTION",
    "\"Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. An Example of this is when the RttMonRttType is 'echo' and the RttMonProtocol is 'snaLU0EchoAppl'. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target.\"",
    "DEFVAL",
    "{",
    "60",
    "}",
    "::=",
    "{",
    "rttMonCtrlAdminEntry",
    "6",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            604800
          ]
        ]
      ]
    ],
    null,
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "mandatory"
    ],
    [
      "DESCRIPTION",
      "Specifies the duration between initiating each RTT operation. This object cannot be set to a value which would be a shorter duration than rttMonCtrlAdminTimeout. When the RttMonRttType specifies an operation that is synchronous in nature, it may happen that the next RTT operation is blocked by a RTT operation which has not yet completed. In this case, the value of a counter (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is incremented in lieu of initiating a RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. An Example of this is when the RttMonRttType is 'echo' and the RttMonProtocol is 'snaLU0EchoAppl'. NOTE: When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', setting this value to a small value for your network size may cause an operation attempt (or multiple attempts) to be started before the previous operation has finished. In this situation the rttMonStatsCollectBusies object will be incremented in lieu of initiating a new RTT operation, and the next attempt will occur at the next rttMonCtrlAdminFrequency expiration. When the rttMonCtrlAdminRttType object is defined to be 'pathEcho', the suggested value for this object is greater than rttMonCtrlAdminTimeout times the maximum number of expected hops to the target."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      60
    ]
  ]
}
  • Preserved mibdepot archive

    Module: CISCO-RTTMON-MIB

    See published definition above

    Module imports
    {'IF-MIB': ['OwnerString'], 'RFC-1212': ['OBJECT-TYPE'], 'RFC-1215': ['TRAP-TYPE'], 'CISCO-SMI': ['ciscoMgmt'], 'SNMPv2-TC-v1': ['DisplayString', 'TruthValue', 'RowStatus', 'TimeInterval', 'TimeStamp'], 'SNMPv2-SMI-v1': ['Integer32', 'Gauge32', 'TimeTicks']}
    · Download CISCO-RTTMON.MIB.txt

Historical records

Additional source information

Information from Circitor
rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX          Integer32 (0..604800)
    UNITS           "seconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "Specifies the duration between initiating each RTT
        operation. 

        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.

        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. 

        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.

        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho', the suggested value for this object 
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target.

        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'dhcp', the minimum allowed value for this
               object is 10 seconds.  This restriction is due to
               protocol limitations described in RFC 2131."
    DEFVAL          { 60 } 
    ::= { rttMonCtrlAdminEntry 6 }
Information from Cisco SMIv1
rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX INTEGER(0..604800)


    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Specifies the duration between initiating each RTT
        operation. 
        
        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.
        
        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. 
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.
        
        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho', the suggested value for this object 
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target.
        
        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'dhcp', the minimum allowed value for this
               object is 10 seconds.  This restriction is due to
               protocol limitations described in RFC 2131."
    DEFVAL { 60 }
    ::= { rttMonCtrlAdminEntry 6 }
Information from MIBdepot
rttMonCtrlAdminFrequency OBJECT-TYPE
  SYNTAX      Integer32 (0..604800)
  UNITS       "seconds"
  MAX-ACCESS  read-create
  STATUS      current
  DESCRIPTION
       "Specifies the duration between initiating each RTT 
       operation. 

       This object cannot be set to a value which would be a 
       shorter duration than rttMonCtrlAdminTimeout.

       When the RttMonRttType specifies an operation that is
       synchronous in nature, it may happen that the next RTT 
       operation is blocked by a RTT operation which has not
       yet completed.  In this case, the value of a counter
       (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
       incremented in lieu of initiating a RTT operation, and 
       the next attempt will occur at the next
       rttMonCtrlAdminFrequency expiration. 

       NOTE:  When the rttMonCtrlAdminRttType object is defined 
              to be 'pathEcho', setting this value to a small
              value for your network size may cause an operation
              attempt (or multiple attempts) to be started 
              before the previous operation has finished.  In 
              this situation the rttMonStatsCollectBusies object
              will be incremented in lieu of initiating a new 
              RTT operation, and the next attempt will occur at
              the next rttMonCtrlAdminFrequency expiration.

       When the rttMonCtrlAdminRttType object is defined
       to be 'pathEcho', the suggested value for this object 
       is greater than rttMonCtrlAdminTimeout times the 
       maximum number of expected hops to the target.

       NOTE:  When the rttMonCtrlAdminRttType object is defined 
              to be 'dhcp', the minimum allowed value for this
              object is 10 seconds.  This restriction is due to
              protocol limitations described in RFC 2131."
  DEFVAL      { 60 }
  ::= { rttMonCtrlAdminEntry 6 }
Information from Cisco
rttMonCtrlAdminFrequency OBJECT-TYPE
    SYNTAX          Integer32 (0..604800)
    UNITS           "seconds"
    MAX-ACCESS      read-create
    STATUS          current
    DESCRIPTION
        "Specifies the duration between initiating each RTT
        operation. 

        This object cannot be set to a value which would be a 
        shorter duration than rttMonCtrlAdminTimeout.

        When the RttMonRttType specifies an operation that is
        synchronous in nature, it may happen that the next RTT 
        operation is blocked by a RTT operation which has not
        yet completed.  In this case, the value of a counter
        (rttMonStatsCollectBusies) in rttMonStatsCaptureTable is
        incremented in lieu of initiating a RTT operation, and 
        the next attempt will occur at the next
        rttMonCtrlAdminFrequency expiration. 

        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'pathEcho', setting this value to a small
               value for your network size may cause an operation
               attempt (or multiple attempts) to be started 
               before the previous operation has finished.  In 
               this situation the rttMonStatsCollectBusies object
               will be incremented in lieu of initiating a new 
               RTT operation, and the next attempt will occur at
               the next rttMonCtrlAdminFrequency expiration.

        When the rttMonCtrlAdminRttType object is defined
        to be 'pathEcho', the suggested value for this object 
        is greater than rttMonCtrlAdminTimeout times the 
        maximum number of expected hops to the target.

        NOTE:  When the rttMonCtrlAdminRttType object is defined 
               to be 'dhcp', the minimum allowed value for this
               object is 10 seconds.  This restriction is due to
               protocol limitations described in RFC 2131."
    DEFVAL          { 60 } 
    ::= { rttMonCtrlAdminEntry 6 }

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9)

Greg Satz

Current Registration Authority (inferred from ancestor 1.3.6.1.4.1.9)

Cisco Systems, Inc.

Siblings (11)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9.9.42.1.2.1.1.1 rttMonCtrlAdminIndex00 Uniquely identifies a row in the rttMonCtrlAdminTable.

This is a pseudo-random number selected by the management
station when cre…
1.3.6.1.4.1.9.9.42.1.2.1.1.2 rttMonCtrlAdminOwner00 Identifies the entity that created this table row.
1.3.6.1.4.1.9.9.42.1.2.1.1.3 rttMonCtrlAdminTag00 A string which is used by a managing application to
identify the RTT target. This string is inserted into trap
notifications, bu…
1.3.6.1.4.1.9.9.42.1.2.1.1.4 rttMonCtrlAdminRttType00 The type of RTT operation to be performed. This value
must be set in the same PDU or before setting any type
specific configurat…
1.3.6.1.4.1.9.9.42.1.2.1.1.5 rttMonCtrlAdminThreshold00 This object defines an administrative threshold limit.
If the RTT operation time exceeds this limit and if the
conditions specifi…
1.3.6.1.4.1.9.9.42.1.2.1.1.7 rttMonCtrlAdminTimeout00 Specifies the duration to wait for a RTT operation
completion. The value of this object cannot be set to
a value which would spe…
1.3.6.1.4.1.9.9.42.1.2.1.1.8 rttMonCtrlAdminVerifyData00 When set to true, the resulting data in each RTT
operation is compared with the expected data. This
includes checking header inf…
1.3.6.1.4.1.9.9.42.1.2.1.1.9 rttMonCtrlAdminStatus00 The status of the conceptual RTT control row.

In order for this object to become active, the following
row objects must be define…
1.3.6.1.4.1.9.9.42.1.2.1.1.10 rttMonCtrlAdminNvgen00 When set to true, this entry will be shown in
'show running' command and can be saved into
Non-volatile memory.
1.3.6.1.4.1.9.9.42.1.2.1.1.11 rttMonCtrlAdminGroupName00 If the operation is created through auto measure group
creation, then this string will specify the group name
to which this opera…
1.3.6.1.4.1.9.9.42.1.2.1.1.12 rttMonCtrlAdminLongTag00 This object provides additional information about the Probe
and is inserted into trap notifications, but has no other
significanc…