Status in source: mandatory.
Names: rttMonCtrlAdminStatus
Technical details
{
"smi_kind": "OBJECT-TYPE",
"definition": [
"rttMonCtrlAdminStatus",
"OBJECT-TYPE",
"SYNTAX",
"RowStatus",
"ACCESS",
"read-write",
"STATUS",
"mandatory",
"DESCRIPTION",
"\"The status of the conceptual RTT control row. In order for this object to become active, the following row objects must be defined: - rttMonCtrlAdminRttType; - when rttMonCtrlAdminRttType is 'echo' or 'pathEcho', rttMonEchoAdminProtocol and rttMonEchoAdminTargetAddress; - when rttMonCtrlAdminRttType is 'fileIO', rttMonFileIOAdminFilePath; - when rttMonCtrlAdminRttType is 'script', rttMonScriptAdminName. All other objects can assume default values. A default conceptual Rtt control row will be placed into a 'pending' state (via the rttMonCtrlOperState object). Most conceptual Rtt control row objects cannot be modified once this conceptual Rtt control row has been created. The objects that can change are the following: - Objects in the rttMonReactAdminTable can be modified as needed without setting this object to 'notInService'. - Objects in the rttMonScheduleAdminTable can be modified only when this object has the value of 'notInService'. - The rttMonCtrlOperState can be modified to control the state of the probe. Once this object is in 'active' status, it cannot be set to 'notInService' while the rttMonCtrlOperState is in 'active' state. Thus the rttMonCtrlOperState object must be transitioned first. This object can be set to 'destroy' from any value at any time. NOTE: In order for all objects in a PDU to be set at the same time, this object can only be part of a multi-bound PDU, when its value is either createAndGo or createAndWait. All other values need to be placed inside singular bound PDU's.\"",
"DEFVAL",
"{",
"createAndGo",
"}",
"::=",
"{",
"rttMonCtrlAdminEntry",
"9",
"}"
],
"syntax_tree": [
[
"row",
"RowStatus"
],
null,
[
"MaxAccessPart",
"read-write"
],
[
"Status",
"mandatory"
],
[
"DESCRIPTION",
"The status of the conceptual RTT control row. In order for this object to become active, the following row objects must be defined: - rttMonCtrlAdminRttType; - when rttMonCtrlAdminRttType is 'echo' or 'pathEcho', rttMonEchoAdminProtocol and rttMonEchoAdminTargetAddress; - when rttMonCtrlAdminRttType is 'fileIO', rttMonFileIOAdminFilePath; - when rttMonCtrlAdminRttType is 'script', rttMonScriptAdminName. All other objects can assume default values. A default conceptual Rtt control row will be placed into a 'pending' state (via the rttMonCtrlOperState object). Most conceptual Rtt control row objects cannot be modified once this conceptual Rtt control row has been created. The objects that can change are the following: - Objects in the rttMonReactAdminTable can be modified as needed without setting this object to 'notInService'. - Objects in the rttMonScheduleAdminTable can be modified only when this object has the value of 'notInService'. - The rttMonCtrlOperState can be modified to control the state of the probe. Once this object is in 'active' status, it cannot be set to 'notInService' while the rttMonCtrlOperState is in 'active' state. Thus the rttMonCtrlOperState object must be transitioned first. This object can be set to 'destroy' from any value at any time. NOTE: In order for all objects in a PDU to be set at the same time, this object can only be part of a multi-bound PDU, when its value is either createAndGo or createAndWait. All other values need to be placed inside singular bound PDU's."
],
null,
null,
null,
[
"DEFVAL",
"createAndGo"
]
]
}