OID reference

thrsLT

1.3.6.1.4.1.9839.2.1.2.27

Description

Low Room Temperature Alarm Threshold

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.2 (analogObjects)
Node code
27
Node names
  • thrsLT
  • hysteresis-Max-Pressure-Alarm-FCM
  • opt-sns-4-y2
  • diff_freec_rl
  • dif_al_agelo_a2
  • probe_2
  • set_vent_inv
  • set_al_agelo_a1
  • t_max_tm_rt_rh
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.2.27
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.2.27
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 2 27}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) analogObjects(2) thrsLT(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) analogObjects(2) hysteresis-Max-Pressure-Alarm-FCM(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) analogObjects(2) opt-sns-4-y2(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) analogObjects(2) thrsLT(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) analogObjects(2) hysteresis-Max-Pressure-Alarm-FCM(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) analogObjects(2) opt-sns-4-y2(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) analogObjects(2) thrsLT(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) analogObjects(2) hysteresis-Max-Pressure-Alarm-FCM(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) analogObjects(2) opt-sns-4-y2(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) analogObjects(2) thrsLT(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) analogObjects(2) hysteresis-Max-Pressure-Alarm-FCM(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) analogObjects(2) opt-sns-4-y2(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) analogObjects(2) thrsLT(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) analogObjects(2) hysteresis-Max-Pressure-Alarm-FCM(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) analogObjects(2) opt-sns-4-y2(27)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) analogObjects(2) thrsLT(27)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/2/27
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/2/27
  • /ISO/3/6/1/4/1/9839/2/1/2/27
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/thrsLT
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/hysteresis-Max-Pressure-Alarm-FCM
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/opt-sns-4-y2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/diff_freec_rl
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/dif_al_agelo_a2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/probe_2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/set_vent_inv
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/set_al_agelo_a1
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/t_max_tm_rt_rh
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/thrsLT
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/hysteresis-Max-Pressure-Alarm-FCM
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/opt-sns-4-y2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/diff_freec_rl
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/dif_al_agelo_a2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/probe_2
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/set_vent_inv
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, °C/°F x10, °C x10, degrees C x10, bar x10
Maximum access defined by MIB
read-write, read-only
Status in MIB
current
Default value
90, 1000, 50, 30, 155

Definitions may combine these properties differently.

Compare 8 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
-999–999

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
°C/°F x10
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
°C x10
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
90
Allowed ranges
0–540

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
1000
Allowed ranges
-32768–32767

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
°C/°F x10
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
50
Allowed ranges
3–199

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
°C/°F x10
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
30
Allowed ranges
-300–32767

Variant 7 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
degrees C x10
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
-32767–32767

Variant 8 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
bar x10
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
155
Allowed ranges
-32767–32767

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.2.27.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 9 distinct definitions; some records may not include a definition.

Show 9 published definitions

hysteresis-Max-Pressure-Alarm-FCM · current

hysteresis-Max-Pressure-Alarm-FCM OBJECT-TYPE
                    SYNTAX Integer32 (-999..999)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Hysteresis Max.Pressure Alarm FCM"
                    ::= { analogObjects 27 }

t_max_tm_rt_rh · current

t_max_tm_rt_rh OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "°C/°F x10"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Maximum temperature measured in rt interval"
                    ::= { analogObjects 27 }

diff_freec_rl · current

diff_freec_rl OBJECT-TYPE
                    SYNTAX Integer32 (0..540)
                    UNITS "°C x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Free cooling differential(only for shelters)"
                    DEFVAL { 90 }
                    ::= { analogObjects 27 }

opt-sns-4-y2 · current

opt-sns-4-y2 OBJECT-TYPE
                    SYNTAX Integer32 (-32768..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Analog Sensor 4 Maximum Value"
                    DEFVAL { 1000 }
                    ::= { analogObjects 27 }

dif_al_agelo_a2 · current

dif_al_agelo_a2 OBJECT-TYPE
                    SYNTAX Integer32 (3..199)
                    UNITS "°C/°F x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Differential for antifreeze/low ambient temperatur"
                    DEFVAL { 50 }
                    ::= { analogObjects 27 }

probe_2 · current

probe_2 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "°C/°F x10"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe 2"
                    ::= { analogObjects 27 }

set_al_agelo_a1 · current

set_al_agelo_a1 OBJECT-TYPE
                    SYNTAX Integer32 (-300..32767)
                    UNITS "°C/°F x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Antifreeze / Low ambient temp alarm set-point"
                    DEFVAL { 30 }
                    ::= { analogObjects 27 }

thrsLT · current

thrsLT OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "degrees C x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Low Room Temperature Alarm Threshold"
                    ::= { analogObjects 27 }

set_vent_inv · current

set_vent_inv OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "bar x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "fan inverter Set Point"
                    DEFVAL { 155 }
                    ::= { analogObjects 27 }

Meaning

Descriptions

9 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Low Room Temperature Alarm Threshold
Original text from OID Repository
thrsLT OBJECT-TYPE
SYNTAX Integer32 (-32767..32767)
UNITS "degrees C x10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Low Room Temperature Alarm Threshold"
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Hysteresis Max.Pressure Alarm FCM

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Maximum temperature measured in rt interval

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Free cooling differential(only for shelters)

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Analog Sensor 4 Maximum Value

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

Differential for antifreeze/low ambient temperatur

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 7

Probe 2

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 8

Antifreeze / Low ambient temp alarm set-point

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 9

fan inverter Set Point

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

9 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

hysteresis-Max-Pressure-Alarm-FCM · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: hysteresis-Max-Pressure-Alarm-FCM

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "hysteresis-Max-Pressure-Alarm-FCM",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "999",
    ".",
    ".",
    "999",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hysteresis Max.Pressure Alarm FCM\"",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -999,
            999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hysteresis Max.Pressure Alarm FCM"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

t_max_tm_rt_rh · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: t_max_tm_rt_rh

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "t_max_tm_rt_rh",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432fc2b0462078313022"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Maximum temperature measured in rt interval\"",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C/°F x10"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Maximum temperature measured in rt interval"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

diff_freec_rl · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: diff_freec_rl

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "diff_freec_rl",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "540",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Free cooling differential(only for shelters)\"",
    "DEFVAL",
    "{",
    "90",
    "}",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            540
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Free cooling differential(only for shelters)"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      90
    ]
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 2 sources

Description 5

opt-sns-4-y2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)2 sources

Status in source: current.

Names: opt-sns-4-y2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "opt-sns-4-y2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32768",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Analog Sensor 4 Maximum Value\"",
    "DEFVAL",
    "{",
    "1000",
    "}",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32768,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Analog Sensor 4 Maximum Value"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      1000
    ]
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

dif_al_agelo_a2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: dif_al_agelo_a2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "dif_al_agelo_a2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "3",
    ".",
    ".",
    "199",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432fc2b0462078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Differential for antifreeze/low ambient temperatur\"",
    "DEFVAL",
    "{",
    "50",
    "}",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            3,
            199
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C/°F x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Differential for antifreeze/low ambient temperatur"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      50
    ]
  ]
}
Records for description 7Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 7

probe_2 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: probe_2

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "probe_2",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432fc2b0462078313022"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe 2\"",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C/°F x10"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe 2"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 8Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 8

set_al_agelo_a1 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: set_al_agelo_a1

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "set_al_agelo_a1",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "300",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432fc2b0462078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Antifreeze / Low ambient temp alarm set-point\"",
    "DEFVAL",
    "{",
    "30",
    "}",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -300,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C/°F x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Antifreeze / Low ambient temp alarm set-point"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      30
    ]
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

thrsLT · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: thrsLT

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "thrsLT",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "226465677265657320432078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Low Room Temperature Alarm Threshold\"",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "degrees C x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Low Room Temperature Alarm Threshold"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 9Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 9

set_vent_inv · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: set_vent_inv

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "set_vent_inv",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "226261722078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"fan inverter Set Point\"",
    "DEFVAL",
    "{",
    "155",
    "}",
    "::=",
    "{",
    "analogObjects",
    "27",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "bar x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "fan inverter Set Point"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      155
    ]
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (86)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.2.52 offset_res, r2900
1.3.6.1.4.1.9839.2.1.2.53 differ_res, r2300
1.3.6.1.4.1.9839.2.1.2.54 tar_umid_amb, r2400
1.3.6.1.4.1.9839.2.1.2.55 r2500
1.3.6.1.4.1.9839.2.1.2.56 r2600
1.3.6.1.4.1.9839.2.1.2.57 s200
1.3.6.1.4.1.9839.2.1.2.58 s300
1.3.6.1.4.1.9839.2.1.2.59 set-effective, s400
1.3.6.1.4.1.9839.2.1.2.60 set-fc, s500
1.3.6.1.4.1.9839.2.1.2.61 setpoint-a-us, sonda_6, fan_on_temp_f100
1.3.6.1.4.1.9839.2.1.2.62 max-setpoint, sonda_7, offset_valv00
1.3.6.1.4.1.9839.2.1.2.63 min-setpoint, sonda_8, diff_valv00
1.3.6.1.4.1.9839.2.1.2.64 diff, set_esternoi00
1.3.6.1.4.1.9839.2.1.2.65 max-diff00
1.3.6.1.4.1.9839.2.1.2.66 min-diff, surriscaldamento, max_comp_i00
1.3.6.1.4.1.9839.2.1.2.67 fcs-out, tmp_superheat, set_vent100
1.3.6.1.4.1.9839.2.1.2.68 set_vent200
1.3.6.1.4.1.9839.2.1.2.69 diff_vent100
1.3.6.1.4.1.9839.2.1.2.70 water-temp, diff_vent200
1.3.6.1.4.1.9839.2.1.2.71 temp-inlet00
1.3.6.1.4.1.9839.2.1.2.72 temp-outlet00
1.3.6.1.4.1.9839.2.1.2.73 flow-value00
1.3.6.1.4.1.9839.2.1.2.74 amp-value00
1.3.6.1.4.1.9839.2.1.2.75 ta-probe-temp-100
1.3.6.1.4.1.9839.2.1.2.76 ta-probe-temp-200
1.3.6.1.4.1.9839.2.1.2.77 pressione100
1.3.6.1.4.1.9839.2.1.2.78 pressione200
1.3.6.1.4.1.9839.2.1.2.79 pump-sp-press00
1.3.6.1.4.1.9839.2.1.2.80 p-wat200
1.3.6.1.4.1.9839.2.1.2.81 temp-amb00
1.3.6.1.4.1.9839.2.1.2.82 temp-fc00
1.3.6.1.4.1.9839.2.1.2.90 pp100
1.3.6.1.4.1.9839.2.1.2.91 pp200
1.3.6.1.4.1.9839.2.1.2.100 cooling-capacity00
1.3.6.1.4.1.9839.2.1.2.101 freecooling-capacity00
1.3.6.1.4.1.9839.2.1.2.102 total-capacity00