OID reference

radcoolSpDX

1.3.6.1.4.1.9839.2.1.2.34

Description

Radcooler Setpoint in DX Mode

Full description and source information

Identification

Identifier and names

Parent
1.3.6.1.4.1.9839.2.1.2 (analogObjects)
Node code
34
Node names
  • radcoolSpDX
  • proportional-Band-Freecooling-PID
  • min_fan_s_f5
  • sonda_b4
  • set_esterno
  • c6
Category
SNMP management object
Numeric OID
1.3.6.1.4.1.9839.2.1.2.34
URN notation
urn:oid:1.3.6.1.4.1.9839.2.1.2.34
ASN.1, OID-IRI and named path variants
ASN.1 notation

{1 3 6 1 4 1 9839 2 1 2 34}

  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) analogObjects(2) radcoolSpDX(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) analogObjects(2) proportional-Band-Freecooling-PID(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) ug40cdzMIB(1) analogObjects(2) c6(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) analogObjects(2) radcoolSpDX(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) analogObjects(2) proportional-Band-Freecooling-PID(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) kelvin-pCOWebMIB-Chiller(1) analogObjects(2) c6(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) analogObjects(2) radcoolSpDX(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) analogObjects(2) proportional-Band-Freecooling-PID(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) dap4-alMIB(1) analogObjects(2) c6(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) analogObjects(2) radcoolSpDX(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) analogObjects(2) proportional-Band-Freecooling-PID(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uacMIB(1) analogObjects(2) c6(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) analogObjects(2) radcoolSpDX(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) analogObjects(2) proportional-Band-Freecooling-PID(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) uncdz-MIB(1) analogObjects(2) c6(34)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) carel(9839) instruments(2) mcellaMIB(1) analogObjects(2) radcoolSpDX(34)}
  • Additional combinations skipped.
OID-IRI notation
  • /1/3/6/1/4/1/9839/2/1/2/34
  • /ISO/Identified-Organization/6/1/4/1/9839/2/1/2/34
  • /ISO/3/6/1/4/1/9839/2/1/2/34
Named path variants
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/radcoolSpDX
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/proportional-Band-Freecooling-PID
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/min_fan_s_f5
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/sonda_b4
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/set_esterno
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/ug40cdzMIB/analogObjects/c6
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/radcoolSpDX
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/proportional-Band-Freecooling-PID
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/min_fan_s_f5
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/sonda_b4
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/set_esterno
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/kelvin-pCOWebMIB-Chiller/analogObjects/c6
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/analogObjects/radcoolSpDX
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/analogObjects/proportional-Band-Freecooling-PID
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/analogObjects/min_fan_s_f5
  • /iso/identified-organization/dod/internet/private/enterprise/9839/instruments/dap4-alMIB/analogObjects/sonda_b4
  • Additional combinations skipped.

SNMP properties

Value type
Integer32
Units
N/A, kh x10, °C x10, degrees C
Maximum access defined by MIB
read-only, read-write
Status in MIB
current
Default value
0, 300, 200

Definitions may combine these properties differently.

Compare 6 source variants

Variant 1 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-only
Status in MIB
current
Allowed ranges
-32767–32767

Variant 2 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
kh x10
Maximum access defined by MIB
read-only
Status in MIB
current
Default value
0
Allowed ranges
0–199

Variant 3 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
N/A
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
-999–999

Variant 4 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
°C x10
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
300
Allowed ranges
-9990–9990

Variant 5 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
°C x10
Maximum access defined by MIB
read-write
Status in MIB
current
Default value
200
Allowed ranges
0–32767

Variant 6 — Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

Value type
Integer32
Units
degrees C
Maximum access defined by MIB
read-write
Status in MIB
current
Allowed ranges
-32767–32767

Using this OID with SNMP

At least one MIB declaration places this object in a scalar group. A scalar instance uses the suffix .0.

snmpget [connection options] DEVICE .1.3.6.1.4.1.9839.2.1.2.34.0

Replace the placeholders with your connection and authentication options. Available permissions and device support can differ from the MIB.

Properties come from available MIB definitions. Actual device support and access can differ. See source records below for original files and qualifications.

Available source records contain 6 distinct definitions; some records may not include a definition.

Show 6 published definitions

sonda_b4 · current

sonda_b4 OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "N/A"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Probe B4"
                    ::= { analogObjects 34 }

c6 · current

c6 OBJECT-TYPE
                    SYNTAX Integer32 (0..199)
                    UNITS "kh x10"
                    MAX-ACCESS read-only
                    STATUS current
                    DESCRIPTION "Hour counter for compressor 2."
                    DEFVAL { 0 }
                    ::= { analogObjects 34 }

proportional-Band-Freecooling-PID · current

proportional-Band-Freecooling-PID  OBJECT-TYPE
                    SYNTAX Integer32 (-999..999)
                    UNITS "N/A"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Proportional Band Freecooling PID"
                    ::= { analogObjects 34 }

set_esterno · current

set_esterno OBJECT-TYPE
                    SYNTAX Integer32 (-9990..9990)
                    UNITS "°C x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Summer compensation control set-point"
                    DEFVAL { 300 }
                    ::= { analogObjects 34 }

min_fan_s_f5 · current

min_fan_s_f5 OBJECT-TYPE
                    SYNTAX Integer32 (0..32767)
                    UNITS "°C x10"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "% reg. band for min speed or temp./pressure for min speed in condens."
                    DEFVAL { 200 }
                    ::= { analogObjects 34 }

radcoolSpDX · current

radcoolSpDX OBJECT-TYPE
                    SYNTAX Integer32 (-32767..32767)
                    UNITS "degrees C"
                    MAX-ACCESS read-write
                    STATUS current
                    DESCRIPTION "Radcooler Setpoint in DX Mode"
                    ::= { analogObjects 34 }

Meaning

Descriptions

6 unique

Identical descriptions are grouped. Different wording and device-specific notes are retained.

Description 1

Radcooler Setpoint in DX Mode
Original text from OID Repository
radcoolSpDX OBJECT-TYPE
SYNTAX Integer32 (-32767..32767)
UNITS "degrees C"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Radcooler Setpoint in DX Mode"
Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

OID Repository

View at oid-base.com

Description 2

Probe B4

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 3

Hour counter for compressor 2.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 4

Proportional Band Freecooling PID

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 5

Summer compensation control set-point

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Description 6

% reg. band for min speed or temp./pressure for min speed in condens.

Sources for this description

Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)

See 1 matching source record

Evidence

Source records

6 records

Matching descriptions are grouped; representative source files are shown for each definition.

Records for description 2Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 2

sonda_b4 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: sonda_b4

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "sonda_b4",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Probe B4\"",
    "::=",
    "{",
    "analogObjects",
    "34",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Probe B4"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 3Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 3

c6 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: c6

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "c6",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "199",
    ")",
    "UNITS",
    [
      "literal",
      "226b682078313022"
    ],
    "MAX-ACCESS",
    "read-only",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Hour counter for compressor 2.\"",
    "DEFVAL",
    "{",
    "0",
    "}",
    "::=",
    "{",
    "analogObjects",
    "34",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            199
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "kh x10"
    ],
    [
      "MaxAccessPart",
      "read-only"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Hour counter for compressor 2."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      0
    ]
  ]
}
Records for description 4Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 4

proportional-Band-Freecooling-PID · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: proportional-Band-Freecooling-PID

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "proportional-Band-Freecooling-PID",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "999",
    ".",
    ".",
    "999",
    ")",
    "UNITS",
    [
      "literal",
      "224e2f4122"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Proportional Band Freecooling PID\"",
    "::=",
    "{",
    "analogObjects",
    "34",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -999,
            999
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "N/A"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Proportional Band Freecooling PID"
    ],
    null,
    null,
    null,
    null
  ]
}
Records for description 5Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 5

set_esterno · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: set_esterno

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "set_esterno",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "9990",
    ".",
    ".",
    "9990",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Summer compensation control set-point\"",
    "DEFVAL",
    "{",
    "300",
    "}",
    "::=",
    "{",
    "analogObjects",
    "34",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -9990,
            9990
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Summer compensation control set-point"
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      300
    ]
  ]
}
Records for description 6Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 6

min_fan_s_f5 · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: min_fan_s_f5

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "min_fan_s_f5",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "0",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "22c2b0432078313022"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"% reg. band for min speed or temp./pressure for min speed in condens.\"",
    "DEFVAL",
    "{",
    "200",
    "}",
    "::=",
    "{",
    "analogObjects",
    "34",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            0,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "°C x10"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "% reg. band for min speed or temp./pressure for min speed in condens."
    ],
    null,
    null,
    null,
    [
      "DEFVAL",
      200
    ]
  ]
}
Records for description 1Multiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 record · 1 source

Description 1

radcoolSpDX · currentMultiple manufacturers; see the original MIB MIB copies (LibreNMS/Observium Community)1 source

Status in source: current.

Names: radcoolSpDX

Technical details
{
  "smi_kind": "OBJECT-TYPE",
  "definition": [
    "radcoolSpDX",
    "OBJECT-TYPE",
    "SYNTAX",
    "Integer32",
    "(",
    "-",
    "32767",
    ".",
    ".",
    "32767",
    ")",
    "UNITS",
    [
      "literal",
      "2264656772656573204322"
    ],
    "MAX-ACCESS",
    "read-write",
    "STATUS",
    "current",
    "DESCRIPTION",
    "\"Radcooler Setpoint in DX Mode\"",
    "::=",
    "{",
    "analogObjects",
    "34",
    "}"
  ],
  "syntax_tree": [
    [
      "SimpleSyntax",
      "Integer32",
      [
        "integerSubType",
        [
          [
            -32767,
            32767
          ]
        ]
      ]
    ],
    [
      "UNITS",
      "degrees C"
    ],
    [
      "MaxAccessPart",
      "read-write"
    ],
    [
      "Status",
      "current"
    ],
    [
      "DESCRIPTION",
      "Radcooler Setpoint in DX Mode"
    ],
    null,
    null,
    null,
    null
  ]
}

Registration

Registration authorities

First Registration Authority (inferred from ancestor 1.3.6.1.4.1.9839)

Fiorindo Sebastiano

Siblings (86)

OIDNameDirect childrenDescendantsDescription
1.3.6.1.4.1.9839.2.1.2.52 offset_res, r2900
1.3.6.1.4.1.9839.2.1.2.53 differ_res, r2300
1.3.6.1.4.1.9839.2.1.2.54 tar_umid_amb, r2400
1.3.6.1.4.1.9839.2.1.2.55 r2500
1.3.6.1.4.1.9839.2.1.2.56 r2600
1.3.6.1.4.1.9839.2.1.2.57 s200
1.3.6.1.4.1.9839.2.1.2.58 s300
1.3.6.1.4.1.9839.2.1.2.59 set-effective, s400
1.3.6.1.4.1.9839.2.1.2.60 set-fc, s500
1.3.6.1.4.1.9839.2.1.2.61 setpoint-a-us, sonda_6, fan_on_temp_f100
1.3.6.1.4.1.9839.2.1.2.62 max-setpoint, sonda_7, offset_valv00
1.3.6.1.4.1.9839.2.1.2.63 min-setpoint, sonda_8, diff_valv00
1.3.6.1.4.1.9839.2.1.2.64 diff, set_esternoi00
1.3.6.1.4.1.9839.2.1.2.65 max-diff00
1.3.6.1.4.1.9839.2.1.2.66 min-diff, surriscaldamento, max_comp_i00
1.3.6.1.4.1.9839.2.1.2.67 fcs-out, tmp_superheat, set_vent100
1.3.6.1.4.1.9839.2.1.2.68 set_vent200
1.3.6.1.4.1.9839.2.1.2.69 diff_vent100
1.3.6.1.4.1.9839.2.1.2.70 water-temp, diff_vent200
1.3.6.1.4.1.9839.2.1.2.71 temp-inlet00
1.3.6.1.4.1.9839.2.1.2.72 temp-outlet00
1.3.6.1.4.1.9839.2.1.2.73 flow-value00
1.3.6.1.4.1.9839.2.1.2.74 amp-value00
1.3.6.1.4.1.9839.2.1.2.75 ta-probe-temp-100
1.3.6.1.4.1.9839.2.1.2.76 ta-probe-temp-200
1.3.6.1.4.1.9839.2.1.2.77 pressione100
1.3.6.1.4.1.9839.2.1.2.78 pressione200
1.3.6.1.4.1.9839.2.1.2.79 pump-sp-press00
1.3.6.1.4.1.9839.2.1.2.80 p-wat200
1.3.6.1.4.1.9839.2.1.2.81 temp-amb00
1.3.6.1.4.1.9839.2.1.2.82 temp-fc00
1.3.6.1.4.1.9839.2.1.2.90 pp100
1.3.6.1.4.1.9839.2.1.2.91 pp200
1.3.6.1.4.1.9839.2.1.2.100 cooling-capacity00
1.3.6.1.4.1.9839.2.1.2.101 freecooling-capacity00
1.3.6.1.4.1.9839.2.1.2.102 total-capacity00