Reference record for OID 1.3.6.1.6.3.10.2.1.3


parent
1.3.6.1.6.3.10.2.1 (snmpEngine)
node code
3
node name
snmpEngineTime
dot oid
1.3.6.1.6.3.10.2.1.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) snmpV2(6) snmpModules(3) snmpFrameworkMIB(10) snmpFrameworkMIBObjects(2) snmpEngine(1) snmpEngineTime(3)}
  • {iso(1) org(3) dod(6) internet(1) snmpV2(6) snmpModules(3) snmpFrameworkMIB(10) snmpFrameworkMIBObjects(2) snmpEngine(1) snmpEngineTime(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) snmpV2(6) snmpModules(3) snmpFrameworkMIB(10) snmpFrameworkMIBObjects(2) snmpEngine(1) snmpEngineTime(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/snmpV2/snmpModules/snmpFrameworkMIB/snmpFrameworkMIBObjects/snmpEngine/snmpEngineTime
  • /iso/org/dod/internet/snmpV2/snmpModules/snmpFrameworkMIB/snmpFrameworkMIBObjects/snmpEngine/snmpEngineTime
  • /iso/iso-identified-organization/dod/internet/snmpV2/snmpModules/snmpFrameworkMIB/snmpFrameworkMIBObjects/snmpEngine/snmpEngineTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/6/3/10/2/1/3

    Description by circitor

    The number of seconds since the value of
    the snmpEngineBoots object last changed.
    When incrementing this object's value would
    cause it to exceed its maximum,
    snmpEngineBoots is incremented as if a
    re-initialization had occurred, and this
    object's value consequently reverts to zero.

    Parsed from file SNMP-FRAMEWORK-MIB.mib
    Module: SNMP-FRAMEWORK-MIB

    Description by cisco_v1

    The number of seconds since the value of
    the snmpEngineBoots object last changed.
    When incrementing this object's value would
    cause it to exceed its maximum,
    snmpEngineBoots is incremented as if a
    re-initialization had occurred, and this
    object's value consequently reverts to zero.

    Description by oid_info

    snmpEngineTime OBJECT-TYPE
    SYNTAX INTEGER (0..2147483647)
    UNITS "seconds"
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION "The number of seconds since the value of
    the snmpEngineBoots object last changed.
    When incrementing this objects value would
    cause it to exceed its maximum,
    snmpEngineBoots is incremented as if a
    re-initialization had occurred, and this
    objects value consequently reverts to zero.
    "

    View at oid-info.com

    Description by mibdepot

    The number of seconds since the value of
    the snmpEngineBoots object last changed.
    When incrementing this object's value would
    cause it to exceed its maximum,
    snmpEngineBoots is incremented as if a
    re-initialization had occurred, and this
    object's value consequently reverts to zero.

    Parsed from file SNMP-FRAMEWORK-MIB.mib.txt
    Company: None
    Module: SNMP-FRAMEWORK-MIB

    Description by cisco

    The number of seconds since the value of
    the snmpEngineBoots object last changed.
    When incrementing this object's value would
    cause it to exceed its maximum,
    snmpEngineBoots is incremented as if a
    re-initialization had occurred, and this
    object's value consequently reverts to zero.

    Information by circitor

    snmpEngineTime OBJECT-TYPE SYNTAX INTEGER (0..2147483647) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds since the value of the snmpEngineBoots object last changed. When incrementing this object's value would cause it to exceed its maximum, snmpEngineBoots is incremented as if a re-initialization had occurred, and this object's value consequently reverts to zero. " ::= { snmpEngine 3 }

    Information by cisco_v1

    snmpEngineTime OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "The number of seconds since the value of the snmpEngineBoots object last changed. When incrementing this object's value would cause it to exceed its maximum, snmpEngineBoots is incremented as if a re-initialization had occurred, and this object's value consequently reverts to zero." ::= { snmpEngine 3 }

    Information by oid_info

    Automatically extracted from RFC3411

    Information by mibdepot

    snmpEngineTime OBJECT-TYPE SYNTAX INTEGER (0..2147483647) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds since the value of the snmpEngineBoots object last changed. When incrementing this object's value would cause it to exceed its maximum, snmpEngineBoots is incremented as if a re-initialization had occurred, and this object's value consequently reverts to zero. " ::= { snmpEngine 3 }

    Information by cisco

    snmpEngineTime OBJECT-TYPE SYNTAX INTEGER (0..2147483647) UNITS "seconds" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds since the value of the snmpEngineBoots object last changed. When incrementing this object's value would cause it to exceed its maximum, snmpEngineBoots is incremented as if a re-initialization had occurred, and this object's value consequently reverts to zero. " ::= { snmpEngine 3 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6)

    US DoD

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.6.3.10.2.1.3.0 snmpEngineTime 0 0 None

    Brothers (3)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.6.3.10.2.1.1 snmpEngineID 1 1 An SNMP engine's administratively-unique identifier.
    1.3.6.1.6.3.10.2.1.2 snmpEngineBoots 1 1 The number of times that the SNMP engine has
    (re-)initialized itself since snmpEngineID
    was last configured.
    1.3.6.1.6.3.10.2.1.4 snmpEngineMaxMessageSize 1 1 The maximum length in octets of an SNMP message
    which this SNMP engine can send or receive and