Objects in TIMETRA-CHASSIS-MIB
OID records
| OID | Name | Description |
|---|---|---|
| 1.3.6.1.4.1.6527.3.1.2.2.1.3.1.19 | tmnxChassisAdminMode | The value of tmnxChassisAdminMode specifies the scaling and feature set for the IOM cards in the chassis. Setting this variable to 'modeA' causes all IOM cards i… |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.22 | tmnxRedSecondaryCPMStatusChange | Generated when there is a change in the secondary CPM status. This notification was made obsolete in the 2.1 release. There is no way to administratively enable… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.6 | tmnxMDAHwIndex | The value of tmnxHwIndex is the index into the tmnxHwTable for the row entry that represents the hardware component information for this MDA card. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.13.1.2 | tmnxCcagPathLastChanged | The value of tmnxCcagPathLastChanged indicates the time this row was last changed. |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.1 | tmnxHwConfigChange | A tmnxHwConfigChange notification is generated when the value of tmnxHwLastChange is updated. It can be used by the NMS to trigger maintenance polls of the hard… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.12.1.3 | tmnxCcagLastChanged | The value of tmnxCcagLastChanged indicates the time this row was last changed. |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.21 | tmnxRedPrimaryCPMFail | Generated when the primary CPM fails. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.7.1.6 | tmnxCpmFlashCapacity | The value of tmnxCpmFlashCapacity indicates the maximum size of this flash unit in 512-byte sectors. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.27 | tmnxMDAMcPathMgmtBwPlcyName | The value of tmnxMDAMcPathMgmtBwPlcyName specifies the multicast policy name configured on the MDA. |
| 1.3.6.1.4.1.6527.3.1.2.2.1.7 | tmnxHwLastChange | The value of sysUpTime when the tmnxHwTable was last changed. |
| 1.3.6.1.4.1.6527.3.1.2.2.8.2.1 | tSyncIfTimingAdmTable | Values for the synchronous interface timing for the chassis. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.20 | tmnxSyncIfTimingBITSQualified | The value of tmnxSyncIfTimingBITSQualified indicates whether the BITS timing reference is qualified for use by the synchronous timing subsystem. If tmnxSyncIfTi… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.14.1.11 | tmnxCcagPathCcMtu | The value of tmnxCcagPathCcMtu specifies the MTU of the path indexed by tmnxCcagId, tmnxCcagPathId, and tmnxCcagPathCcType. When the value is '0', the real MTU i… |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1 | tmnxChassisPowerSupplyEntry | Contains information regarding a power supply tray. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.9.1 | tmnxCardTypeEntry | Each row entry represents an Alcatel 7x50 SR series Card model. Rows in this table are created by the agent at initialization and cannot be created or destroyed … |
| 1.3.6.1.4.1.6527.3.1.2.2.1 | tmnxChassisObjs | |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.42 | tmnxChassisUpgradeComplete | The tmnxChassisUpgradeComplete notification is generated to indicate that all the IOMs are running matching software version in reference to the active CPM softw… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.4.1.27 | tmnxCpmCardConfigSource | The value of tmnxCpmCardConfigSource indicates the location in the Boot Options File(BOF) where the configuration file was found when the system last rebooted. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.15.1.2 | tmnxMcmSupportedTypes | A bit-mask that specifies what MCM types can be physically supported in this chassis. |
| 1.3.6.1.4.1.6527.3.1.2.2.1.5.1.4 | tmnxChassisPowerSupplyTempStatus | If the value of tmnxChassisPowerSupplyTempStatus is 'deviceStateOk', the current temperature is within acceptable range. If the value is 'deviceStateFailed', a t… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.4.1.26 | tmnxCpmCardBootOptionSource | tmnxCpmCardBootOptionSource indicates the compact flash slot where the Boot Options File (BOF) file was found when the system last rebooted. For example, if the … |
| 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.18 | tmnxHwTemperature | The current temperature reading in degrees celsius from this hardware component's temperature sensor. If this component does not contain a temperature sensor, t… |
| 1.3.6.1.4.1.6527.3.1.2.2.1.3.1.11 | tmnxChassisNumFans | The total number of fans installed in this chassis. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.14.1.10 | tmnxCcagPathCcMac | The value of tmnxCcagPathCcMac specifies the MAC address of the virtual LAG that maps to tmnxCcagPathId and tmnxCcagPathCcType. The default value of this object … |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.4 | tmnxEqPowerSupplyInserted | Generated when one of the chassis's power supplies is inserted. |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.12 | tmnxEqMemoryFailure | Generated when a memory module failure is detected for an IOM card or CPM module. This notification was made obsolete in the 2.1 release. A failure of the memory… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.12 | tmnxMDANetworkIngQueues | Specifies the network queue policy being used for this object to define the queueing structure for this object. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.12.1.5 | tmnxCcagAdminStatus | The value of tmnxCcagAdminStatus specifies the desired state of this CCAG. |
| 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.5 | tmnxHwSerialNumber | The unique Alcatel 7x50 SR series serial number of the hardware component. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.16.1.2 | tmnxMcmTypeName | The administrative name that identifies this type of Alcatel 7710 series MCM model. This name string may be used in CLI commands to specify a particular card mo… |
| 1.3.6.1.4.1.6527.3.1.2.2.8.1.2 | tmnxChassisAdminControlApply | This object controls the use of tmnxChassisAdminTable. when set to initialize(2), the objects in tmnxChassisAdminTable are set to the current Operational values… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.4.1.25 | tmnxCpmCardIndexFileLastBootedHeader | tmnxCpmCardIndexFileLastBootedHeader contains the header of the index file from which the system last rebooted. |
| 1.3.6.1.4.1.6527.3.1.3.2.1.0.34 | tmnxPeSoftwareLoadFailed | Generated when the CPM fails to load the software from a specified location. tmnxChassisNotifyHwIndex identifies the card for which the software load failed and t… |
| 1.3.6.1.4.1.6527.3.1.2.2.1.9.1.1 | tmnxHwContainedIndex | The value of tmnxHwIndex for the contained hardware component. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.15.1 | tmnxMcmEntry | Each row entry represents a MCM in a chassis in the 7710 system. Entries in the table cannot be created and deleted via SNMP SET operations. When a tmnxChassisE… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.4.1.18 | tmnxCpmCardMemorySize | The value of tmnxCpmCardMemorySize indicates the amount of memory, in mega-bytes, populated on this CPM module. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.16.1 | tmnxMcmTypeEntry | Each row entry represents an Alcatel 7710 series MCM model. Rows in this table are created by the agent at initialization and cannot be created or destroyed by S… |
| 1.3.6.1.4.1.6527.3.1.1.2.1.2.13 | tmnxMDAV4v0Group | The group of objects supporting management of MDAs for release 4.0 on Alcatel 7x50 SR series systems. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.4 | tmnxMDAAssignedType | An integer that indicates the administratively assigned (pre-provisioned) MDA card type that should occupy this slot in this chassis. If tmnxMDAAssignedType has… |
| 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.2 | tmnxHwID | The value of tmnxHwID is an object identifier that points to the table and row entry with additional management information specific to this hardware component's… |
| 1.3.6.1.4.1.6527.3.1.2.2.1.8.1.17 | tmnxHwTempSensor | The value of tmnxHwTempSensor indicates whether or not this hardware component contains a temperature sensor. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.7.1.7 | tmnxCpmFlashUsed | The value of tmnxCpmFlashUsed indicates the amount used, in 512-byte sectors, of this flash unit's total capacity. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.8.1.17 | tmnxMDAChannelsInUse | tmnxMDAChannelsInUse is applicable for SONET and TDM MDAs only. It indicates the total number of leaf SONET paths, TDM channels and bundles on the MDA which are… |
| 1.3.6.1.4.1.6527.3.1.2.2.1.3.1.4 | tmnxChassisType | The type of chassis used in this Alcatel 7x50 system. The value of tmnxChassisType is the tmnxChassisTypeIndex for the entry in the tmnxChassisTypeTable that re… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.11.1.7 | tmnxSyncIfTimingRef1Qualified | The value of tmnxSyncIfTimingRef1Qualified indicates whether the first timing reference is qualified for use by the synchronous timing subsystem. If tmnxSyncIfT… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.4 | tmnxCpmCardTable | The tmnxCpmCardTable has an entry for each CPM card or module in each chassis in the TMNX system. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.7.1 | tmnxCpmFlashEntry | Contains information regarding a CPM card's flash unit. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.4.1.30 | tmnxCpmCardMasterSlaveRefState | The current Master/Slave clocking reference designation. primaryRef Indicates this card is designated as the primary clocking reference in a redundant sys… |
| 1.3.6.1.4.1.6527.3.1.2.2.3.6.1.4 | tmnxFabricHwIndex | The value of tmnxHwIndex is the index into the tmnxHwTable to locate the row entry that represents the hardware component information for this fabric card. |
| 1.3.6.1.4.1.6527.3.1.2.2.3.10 | tmnxMdaTypeTable | The MDA type table has an entry for each Alcatel 7x50 SR series MDA card model. |