Objects in TIMETRA-PORT-MIB

OID records

OIDNameDescription
1.3.6.1.4.1.6527.3.1.2.2.4.8.1.2tmnxPortConnectTypeNameThe administrative name that identifies this type of Alcatel
7x50 SR series port connector model. This name string may be
used in CLI commands to specify a part…
1.3.6.1.4.1.6527.3.1.2.2.4.11.1.7tmnxDS3ChannelSubrate
1.3.6.1.4.1.6527.3.1.2.2.4.2.1.34tmnxPortSFPEquippedIndicates if the SFP is equipped.
1.3.6.1.4.1.6527.3.1.2.2.9.1.1.3tmnxFRDlcmiN393DcetmnxFRDlcmiN393Dce is used to configure the LMI monitored
event count for DCE interface.
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.26tmnxSonetHoldTimeDownThe value of tmnxSonetHoldTimeDown is used to configure the
hold-timer for link down event dampening. This guards against
reporting excessive interface transitio…
1.3.6.1.4.1.6527.3.1.2.2.4.5.1tmnxSonetEntryEach row entry represents a packet over Sonet port on a
IOM card in a chassis in the system. Entries cannot be
created and deleted via SNMP SET operations. Bef…
1.3.6.1.4.1.6527.3.1.2.2.4.31.1.34tmnxDDMAux2LowWarningThe value of tmnxDDMAux2LowWarning indicates the Manufacturer specific
Auxiliary 2 low-warning threshold for the XFP.
1.3.6.1.4.1.6527.3.1.1.2.2.2.23tmnxPortATMV3v0GroupThe group of objects supporting management of ATM interfaces
for version 3.0 on Alcatel 7x50 SR series systems.
1.3.6.1.4.1.6527.3.1.2.2.4.11.1.23tmnxDS3ChannelMTUThe size of the largest packet which can be sent/received
on the port, specified in octets. For ports that
are used for transmitting network datagrams, this is …
1.3.6.1.4.1.6527.3.1.2.2.4.24.1.17tmnxPortSchedOverrideLvl7PIRThe value of tmnxPortSchedOverrideLvl7PIR specifies the total
bandwidth limit, PIR, for priority level 7. This object
overrides TIMETRA-QOS-MIB::tPortSchedulerPl…
1.3.6.1.4.1.6527.3.1.2.2.4.5.1.14tmnxSonetApsHoldTimeAutomatic Protection Switching (APS) is supported on 7x50 systems
by the APS-MIB and TIMETRA-APS-MIB.
1.3.6.1.4.1.6527.3.1.2.2.4.25.1.2tmnxBPGrpAssocProtectBundleIDtmnxBPGrpAssocProtectBundleID identifies the protection bundle. A value
of zero is given if no protection bundle is associated with the given
tmnxBundleBundleID.
1.3.6.1.4.1.6527.3.1.2.2.4.21.1tmnxBundleImaGrpEntryEach row entry contains data on an IMA Group.
1.3.6.1.4.1.6527.3.1.2.2.4.1tmnxPortTableLastChangeThe value of sysUpTime when the tmnxPortTable was last changed.
1.3.6.1.4.1.6527.3.1.2.2.4.2.1.35tmnxPortEquippedIndicates if there is an optics pack installed in this
port or not.
1.3.6.1.4.1.6527.3.1.3.2.2.0.2tmnxEqPortFailureGenerated when a port has failed.

This notification was made obsolete in the 2.1 release.

tmnxEqPortError is used instead of tmnxEqPortFailure.

Standard IETF li…
1.3.6.1.4.1.6527.3.1.2.2.4.31.1.26tmnxDDMRxOpticalPowerTypeThe value of tmnxDDMRxOpticalPowerType indicates whether the
tmnxDDMRxOpticalPower was taken as an average, or as an Optical
Modulation Amplitude (OMA).
1.3.6.1.4.1.6527.3.1.2.2.9.1.1.6tmnxFRDlcmiRxStatusEnqMsgstmnxFRDlcmiRxStatusEnqMsgs indicates the number of LMI Status
Enquiry messages received on this Frame Relay interface.
1.3.6.1.4.1.6527.3.1.2.2.4.6.1.11tmnxSonetPathAcctPolicyIdThe value of the accounting policy must be defined prior to associating
the policy with the sonet path. Accounting policies can only be
associated with network s…
1.3.6.1.4.1.6527.3.1.2.2.4.13.1.4tmnxDS0ChanGroupCRCThe value of tmnxDS0ChanGroupCRC variable indicates the precision of
the cyclic redundancy check. A value of 'crc16' is a 16-bit
CRC calculation. A value of 'c…
1.3.6.1.4.1.6527.3.1.2.2.4.22.1.16tmnxBundleMemberImaFeTxUnuseSecstmnxBundleMemberImaFeTxUnuseSecs indicates the number
of unavailable seconds at the far-end transmit link
state machine.
1.3.6.1.4.1.6527.3.1.2.2.4.7tmnxPortTypeTableThe Port type table has an entry for each Alcatel 7x50 SR series
port model.
1.3.6.1.4.1.6527.3.1.2.2.4.3.1.8tmnxPortTestActionThe operator sets this variable to perform the appropriate
type of testing.
1.3.6.1.4.1.6527.3.1.2.2.4.11.1.33tmnxDS3ChannelBERTErrorstmnxDS3ChannelBERTErrors is the number of bit errors detected during
the last BERT test. It is valid only after tmnxDS3ChannelBERTOperStatus
transitioned from 'a…
1.3.6.1.4.1.6527.3.1.2.2.4.14tmnxBundleTableThe tmnxBundleTable has an entry for a bundle created on the system.
1.3.6.1.4.1.6527.3.1.2.2.4.8.1.1tmnxPortConnectTypeIndexThe unique index value which identifies this type of Alcatel
7x50 SR series port connector model.
1.3.6.1.4.1.6527.3.1.2.2.4.9.1.13tmnxPortFCStatsEgrFwdOutProfOctsThe number of out-of-profile octets (rate above CIR)
forwarded by the egress Qchip.
1.3.6.1.4.1.6527.3.1.2.2.4.2.1.14tmnxPortHoldTimeUpThe value of tmnxPortHoldTimeUp is used to configure the
hold-timer for link up event dampening. This guards against
reporting excessive interface transitions. T…
1.3.6.1.4.1.6527.3.1.2.2.4.11.1.32tmnxDS3ChannelBERTSynchedtmnxDS3ChannelBERTSynched is the number of seconds for which the
BERT hardware was synchronized. This will be less than or equal to
the duration of the last BERT…
1.3.6.1.4.1.6527.3.1.2.2.4.12.1.9tmnxDS1BERTDurationtmnxDS1BERTDuration is used to set the duration of the BERT test.
1.3.6.1.4.1.6527.3.1.2.2.4.21tmnxBundleImaGrpTableThe tmnxBundleImaGrpTable contains IMA Group data
1.3.6.1.4.1.6527.3.1.2.2.4.17.1.18tmnxPortIngrMdaQos08StatDropOctstmnxPortIngrMdaQos08StatDropOcts indicates the number of
octets dropped on the oversubscribed MDA for given Qos
classifier result because of an overload conditio…
1.3.6.1.4.1.6527.3.1.2.2.12.1.1.3tmnxPortNetIngressFwdOutProfPktstmnxPortNetIngressFwdOutProfPkts indicates the number of exceeding
network ingress packets forwarded on this port using this queue.
1.3.6.1.4.1.6527.3.1.2.2.10.2.1tmnxQosPoolAppEntryThis entry maintains the specifics about the association of a
buffer pool and an object.
1.3.6.1.4.1.6527.3.1.1.2.2.2.27tmnxMlBundleV3v0GroupThe group of objects supporting management MLBUNDLES
for revision 3.0 on the Alcatel 7x50 SR series systems.
1.3.6.1.4.1.6527.3.1.2.2.4.2.1.2tmnxPortLastChangeTimeThe tmnxPortLastChangeTime variable contains the sysUpTime
value of the most recently modified writable variable in the
tmnxPortEntry row for this port.
1.3.6.1.4.1.6527.3.1.2.2.9tmnxFRObjs
1.3.6.1.4.1.6527.3.1.1.2.2.1.3.2tmnxPortComp7750V4v0The compliance statement for revision 4.0 of TIMETRA-PORT-MIB on
the Alcatel 7750 SR series systems.

tmnxMlImaBundleGroup was added as of R4.
1.3.6.1.4.1.6527.3.1.1.2.2.2.40tmnxMlBundleGroupV5v0The group of objects supporting management MLBUNDLES
for revision 5.0 on the Alcatel 7x50 SR series systems.
1.3.6.1.4.1.6527.3.1.2.2.10.2.1.2tmnxObjectIdtmnxObjectId is used to identify the specific object. If
tmnxObjectType is 'mda', then the tmnxObjectId is encoded as a
physical port with the port being '0'. Fo…
1.3.6.1.4.1.6527.3.1.2.2.4.24.1.16tmnxPortSchedOverrideLvl6CIRThe value of tmnxPortSchedOverrideLvl6CIR specifies the within-cir
bandwidth limit for priority level 6. This object overrides
TIMETRA-QOS-MIB::tPortSchedulerPlc…
1.3.6.1.4.1.6527.3.1.2.2.4.31.1.46tmnxDDMExtCalTxLaserBiasSlopeThe value of tmnxDDMExtCalTxLaserBiasSlope indicates the
Tx_l(Slope) value as specified in Table 3.16 in the SFF
Committee Standard's document SFF-8472 Rev 10.2.
1.3.6.1.4.1.6527.3.1.2.2.4.21.1.5tmnxBundleImaGrpRxIdtmnxBundleImaGrpRxId specifies the IMA ID generated at group
creation time used by the far-end.
1.3.6.1.4.1.6527.3.1.2.2.4.15.1.3tmnxBundleMemberDownReasontmnxBundleMemberDownReason contains the reason code for marking
the member link of the bundle to down (i.e. tmnxBundleMemberActive
will be set to false):
none - T…
1.3.6.1.4.1.6527.3.1.2.2.4.2.1.4tmnxPortClassThe class of port or optical pack installed. This can be
derived from tmnxPortType.
1.3.6.1.4.1.6527.3.1.2.2.4.14.1.8tmnxBundleOperMRRUtmnxBundleOperMRRU indicates the operational value of
Max Received Reconstructed Unit (MRRU).
This object is only applicable to tmnxBundleType values of mlppp or
…
1.3.6.1.4.1.6527.3.1.2.2.4.31.1.25tmnxDDMRxOpticalPowerHiAlarmThe value of tmnxDDMRxOpticalPowerHiAlarm indicates the Received
Optical Power of the SFP/XFP in micro-Watts (uW) that triggers a
hi-alarm.
1.3.6.1.4.1.6527.3.1.2.2.4.2.1.62tmnxPortIngPoolPercentRateThe value of tmnxPortIngPoolPercentRate specifies increment or
decrement of the active bandwidth associated with the ingress port.
This active bandwidth affects …
1.3.6.1.4.1.6527.3.1.2.2.4.6.1.8tmnxSonetPathOperMTUThe negotiated size of the largest packet which can be sent on
the sonet path, specified in octets. For sonet paths that are used
for transmitting network datag…
1.3.6.1.4.1.6527.3.1.3.2.2.0.30tmnxEqPortEtherLoopDetectedThe tmnxEqPortEtherLoopDetected notification is genereated when
down-when-looped detects an Ethernet port is receiving PDUs that
it transmitted and tmnxPortEther…