optIfOTSnCurrentStatus OBJECT-TYPE
SYNTAX BITS {
bdiP(0),
bdiO(1),
bdi(2),
tim(3),
losP(4),
losO(5),
los(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is applicable when optIfOTSnDirectionality
has the value sink(1) or bidirectional(3). In
reduced-capability systems or at IrDI interfaces
the only bit position that may be set is los(6)."
View at oid-info.com
Indicates the defect condition of the entity, if any.
This object is applicable when optIfOTSnDirectionality
has the value sink(1) or bidirectional(3). In
reduced-capability systems or at IrDI interfaces
the only bit position that may be set is los(6).
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
Indicates the defect condition of the entity, if any.
This object is applicable when optIfOTSnDirectionality
has the value sink(1) or bidirectional(3). In
reduced-capability systems or at IrDI interfaces
the only bit position that may be set is los(6).
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfOTSnCurrentStatus OBJECT-TYPE SYNTAX BITS { bdiP(0), bdiO(1), bdi(2), tim(3), losP(4), losO(5), los(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the defect condition of the entity, if any. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). In reduced-capability systems or at IrDI interfaces the only bit position that may be set is los(6)." ::= { optIfOTSnConfigEntry 10 }
optIfOTSnCurrentStatus OBJECT-TYPE SYNTAX BITS { bdiP(0), bdiO(1), bdi(2), tim(3), losP(4), losO(5), los(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the defect condition of the entity, if any. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(3). In reduced-capability systems or at IrDI interfaces the only bit position that may be set is los(6)." ::= { optIfOTSnConfigEntry 10 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.3.1.1.1 | optIfOTSnDirectionality | 0 | 0 | Indicates the directionality of the entity. |
1.3.6.1.2.1.10.133.1.3.1.1.2 | optIfOTSnAprStatus | 0 | 0 | This attribute indicates the status of the Automatic Power Reduction (APR) function of the entity. Valid values are 'on' and 'of… |
1.3.6.1.2.1.10.133.1.3.1.1.3 | optIfOTSnAprControl | 0 | 0 | This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (wh… |
1.3.6.1.2.1.10.133.1.3.1.1.4 | optIfOTSnTraceIdentifierTransmitted | 0 | 0 | The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional… |
1.3.6.1.2.1.10.133.1.3.1.1.5 | optIfOTSnDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(… |
1.3.6.1.2.1.10.133.1.3.1.1.6 | optIfOTSnSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(… |
1.3.6.1.2.1.10.133.1.3.1.1.7 | optIfOTSnTraceIdentifierAccepted | 0 | 0 | The actual trace identifier received. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirection… |
1.3.6.1.2.1.10.133.1.3.1.1.8 | optIfOTSnTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable when optIfOTSnDirectiona… |
1.3.6.1.2.1.10.133.1.3.1.1.9 | optIfOTSnTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable when optI… |