optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
SYNTAX OptIftxTI
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The trace identifier transmitted.
This object is applicable when optIfOTSnDirectionality has the
value source(2) or bidirectional(3).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value IrDI).
If no value is ever set by a management entity for the object
optIfOTSnTraceIdentifierTransmitted, system-specific default
value will be used. Any implementation that instantiates this
object must document the system-specific default value or how it
is derived."
View at oid-info.com
The trace identifier transmitted.
This object is applicable when optIfOTSnDirectionality has the
value source(2) or bidirectional(3).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI').
If no value is ever set by a management entity for the object
optIfOTSnTraceIdentifierTransmitted, system-specific default
value will be used. Any implementation that instantiates this
object must document the system-specific default value or how it
is derived.
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
The trace identifier transmitted.
This object is applicable when optIfOTSnDirectionality has the
value source(2) or bidirectional(3).
This object does not apply to reduced-capability systems (i.e.,
those for which optIfOTMnReduced has the value true(1)) or
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
has the value 'IrDI').
If no value is ever set by a management entity for the object
optIfOTSnTraceIdentifierTransmitted, system-specific default
value will be used. Any implementation that instantiates this
object must document the system-specific default value or how it
is derived.
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE SYNTAX OptIfTxTI MAX-ACCESS read-write STATUS current DESCRIPTION "The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). If no value is ever set by a management entity for the object optIfOTSnTraceIdentifierTransmitted, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived." ::= { optIfOTSnConfigEntry 4 }
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE SYNTAX OptIfTxTI MAX-ACCESS read-write STATUS current DESCRIPTION "The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). If no value is ever set by a management entity for the object optIfOTSnTraceIdentifierTransmitted, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived." ::= { optIfOTSnConfigEntry 4 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.3.1.1.1 | optIfOTSnDirectionality | 0 | 0 | Indicates the directionality of the entity. |
1.3.6.1.2.1.10.133.1.3.1.1.2 | optIfOTSnAprStatus | 0 | 0 | This attribute indicates the status of the Automatic Power Reduction (APR) function of the entity. Valid values are 'on' and 'of… |
1.3.6.1.2.1.10.133.1.3.1.1.3 | optIfOTSnAprControl | 0 | 0 | This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (wh… |
1.3.6.1.2.1.10.133.1.3.1.1.5 | optIfOTSnDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(… |
1.3.6.1.2.1.10.133.1.3.1.1.6 | optIfOTSnSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(… |
1.3.6.1.2.1.10.133.1.3.1.1.7 | optIfOTSnTraceIdentifierAccepted | 0 | 0 | The actual trace identifier received. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirection… |
1.3.6.1.2.1.10.133.1.3.1.1.8 | optIfOTSnTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable when optIfOTSnDirectiona… |
1.3.6.1.2.1.10.133.1.3.1.1.9 | optIfOTSnTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable when optI… |
1.3.6.1.2.1.10.133.1.3.1.1.10 | optIfOTSnCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. This object is applicable when optIfOTSnDirectionality has the value sink(1… |