Reference record for OID 1.3.6.1.2.1.10.133.1.3.1.1.4



parent
1.3.6.1.2.1.10.133.1.3.1.1 (optIfOTSnConfigEntry)
node code
4
node name
optIfOTSnTraceIdentifierTransmitted
dot oid
1.3.6.1.2.1.10.133.1.3.1.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfOTSn(3) optIfOTSnConfigTable(1) optIfOTSnConfigEntry(1) optIfOTSnTraceIdentifierTransmitted(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfOTSn(3) optIfOTSnConfigTable(1) optIfOTSnConfigEntry(1) optIfOTSnTraceIdentifierTransmitted(4)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfOTSn(3) optIfOTSnConfigTable(1) optIfOTSnConfigEntry(1) optIfOTSnTraceIdentifierTransmitted(4)}
  • {iso(1) org(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfOTSn(3) optIfOTSnConfigTable(1) optIfOTSnConfigEntry(1) optIfOTSnTraceIdentifierTransmitted(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib-2(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfOTSn(3) optIfOTSnConfigTable(1) optIfOTSnConfigEntry(1) optIfOTSnTraceIdentifierTransmitted(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) mgmt(2) mib(1) transmission(10) optIfMibModule(133) optIfObjects(1) optIfOTSn(3) optIfOTSnConfigTable(1) optIfOTSnConfigEntry(1) optIfOTSnTraceIdentifierTransmitted(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfOTSn/optIfOTSnConfigTable/optIfOTSnConfigEntry/optIfOTSnTraceIdentifierTransmitted
  • /iso/identified-organization/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfOTSn/optIfOTSnConfigTable/optIfOTSnConfigEntry/optIfOTSnTraceIdentifierTransmitted
  • /iso/org/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfOTSn/optIfOTSnConfigTable/optIfOTSnConfigEntry/optIfOTSnTraceIdentifierTransmitted
  • /iso/org/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfOTSn/optIfOTSnConfigTable/optIfOTSnConfigEntry/optIfOTSnTraceIdentifierTransmitted
  • /iso/iso-identified-organization/dod/internet/mgmt/mib-2/transmission/optIfMibModule/optIfObjects/optIfOTSn/optIfOTSnConfigTable/optIfOTSnConfigEntry/optIfOTSnTraceIdentifierTransmitted
  • /iso/iso-identified-organization/dod/internet/mgmt/mib/transmission/optIfMibModule/optIfObjects/optIfOTSn/optIfOTSnConfigTable/optIfOTSnConfigEntry/optIfOTSnTraceIdentifierTransmitted
  • iri by oid_info
    /ISO/Identified-Organization/6/1/2/1/10/133/1/3/1/1/4

    Description by oid_info

    optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
    SYNTAX OptIftxTI
    MAX-ACCESS read-write
    STATUS current
    DESCRIPTION
    "The trace identifier transmitted.
    This object is applicable when optIfOTSnDirectionality has the
    value source(2) or bidirectional(3).
    This object does not apply to reduced-capability systems (i.e.,
    those for which optIfOTMnReduced has the value true(1)) or
    at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
    has the value IrDI).
    If no value is ever set by a management entity for the object
    optIfOTSnTraceIdentifierTransmitted, system-specific default
    value will be used. Any implementation that instantiates this
    object must document the system-specific default value or how it
    is derived."

    View at oid-info.com

    Description by mibdepot

    The trace identifier transmitted.
    This object is applicable when optIfOTSnDirectionality has the
    value source(2) or bidirectional(3).
    This object does not apply to reduced-capability systems (i.e.,
    those for which optIfOTMnReduced has the value true(1)) or
    at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
    has the value 'IrDI').
    If no value is ever set by a management entity for the object
    optIfOTSnTraceIdentifierTransmitted, system-specific default
    value will be used. Any implementation that instantiates this
    object must document the system-specific default value or how it
    is derived.

    Parsed from file rfc3591-Optical-Interface-Type.mib.txt
    Company: None
    Module: OPT-IF-MIB

    Description by circitor

    The trace identifier transmitted.
    This object is applicable when optIfOTSnDirectionality has the
    value source(2) or bidirectional(3).
    This object does not apply to reduced-capability systems (i.e.,
    those for which optIfOTMnReduced has the value true(1)) or
    at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
    has the value 'IrDI').
    If no value is ever set by a management entity for the object
    optIfOTSnTraceIdentifierTransmitted, system-specific default
    value will be used. Any implementation that instantiates this
    object must document the system-specific default value or how it
    is derived.

    Parsed from file OPT-IF-MIB.mib
    Module: OPT-IF-MIB

    Information by oid_info

    Automatically extracted from RFC3591

    Information by mibdepot

    optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE SYNTAX OptIfTxTI MAX-ACCESS read-write STATUS current DESCRIPTION "The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). If no value is ever set by a management entity for the object optIfOTSnTraceIdentifierTransmitted, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived." ::= { optIfOTSnConfigEntry 4 }

    Information by circitor

    optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE SYNTAX OptIfTxTI MAX-ACCESS read-write STATUS current DESCRIPTION "The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional(3). This object does not apply to reduced-capability systems (i.e., those for which optIfOTMnReduced has the value true(1)) or at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1 has the value 'IrDI'). If no value is ever set by a management entity for the object optIfOTSnTraceIdentifierTransmitted, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived." ::= { optIfOTSnConfigEntry 4 }

    First Registration Authority (recovered by parent 1.3.6)

    Defense Communication Agency

    Current Registration Authority (recovered by parent 1.3.6.1.2)

    Internet Assigned Numbers Authority

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.2.1.10.133.1.3.1.1.1 optIfOTSnDirectionality 0 0 Indicates the directionality of the entity.
    1.3.6.1.2.1.10.133.1.3.1.1.2 optIfOTSnAprStatus 0 0 This attribute indicates the status of the Automatic
    Power Reduction (APR) function of the entity. Valid
    values are 'on' and 'of…
    1.3.6.1.2.1.10.133.1.3.1.1.3 optIfOTSnAprControl 0 0 This object is a UTF-8 encoded string that specifies Automatic
    Power Reduction (APR) control actions requested of this entity
    (wh…
    1.3.6.1.2.1.10.133.1.3.1.1.5 optIfOTSnDAPIExpected 0 0 The DAPI expected by the receiver.
    This object is applicable when optIfOTSnDirectionality has the
    value sink(1) or bidirectional(…
    1.3.6.1.2.1.10.133.1.3.1.1.6 optIfOTSnSAPIExpected 0 0 The SAPI expected by the receiver.
    This object is applicable when optIfOTSnDirectionality has the
    value sink(1) or bidirectional(…
    1.3.6.1.2.1.10.133.1.3.1.1.7 optIfOTSnTraceIdentifierAccepted 0 0 The actual trace identifier received.
    This object is applicable when optIfOTSnDirectionality has the
    value sink(1) or bidirection…
    1.3.6.1.2.1.10.133.1.3.1.1.8 optIfOTSnTIMDetMode 0 0 Indicates the mode of the Trace Identifier Mismatch (TIM)
    Detection function. This object is applicable
    when optIfOTSnDirectiona…
    1.3.6.1.2.1.10.133.1.3.1.1.9 optIfOTSnTIMActEnabled 0 0 Indicates whether the Trace Identifier Mismatch (TIM)
    Consequent Action function is enabled. This object
    is applicable when optI…
    1.3.6.1.2.1.10.133.1.3.1.1.10 optIfOTSnCurrentStatus 0 0 Indicates the defect condition of the entity, if any.
    This object is applicable when optIfOTSnDirectionality
    has the value sink(1…