optIfOTSnAprControl OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a UTF-8 encoded string that specifies Automatic
Power Reduction (APR) control actions requested of this entity
(when written) and that returns the current APR control state
of this entity (when read). The values are implementation-defined.
Any implementation that instantiates this object must document the
set of values that it allows to be written, the set of values
that it will return, and what each of those values means."
View at oid-info.com
This object is a UTF-8 encoded string that specifies Automatic
Power Reduction (APR) control actions requested of this entity
(when written) and that returns the current APR control state
of this entity (when read). The values are implementation-defined.
Any implementation that instantiates this object must document the
set of values that it allows to be written, the set of values
that it will return, and what each of those values means.
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
This object is a UTF-8 encoded string that specifies Automatic
Power Reduction (APR) control actions requested of this entity
(when written) and that returns the current APR control state
of this entity (when read). The values are implementation-defined.
Any implementation that instantiates this object must document the
set of values that it allows to be written, the set of values
that it will return, and what each of those values means.
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfOTSnAprControl OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (when written) and that returns the current APR control state of this entity (when read). The values are implementation-defined. Any implementation that instantiates this object must document the set of values that it allows to be written, the set of values that it will return, and what each of those values means." ::= { optIfOTSnConfigEntry 3 }
optIfOTSnAprControl OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-write STATUS current DESCRIPTION "This object is a UTF-8 encoded string that specifies Automatic Power Reduction (APR) control actions requested of this entity (when written) and that returns the current APR control state of this entity (when read). The values are implementation-defined. Any implementation that instantiates this object must document the set of values that it allows to be written, the set of values that it will return, and what each of those values means." ::= { optIfOTSnConfigEntry 3 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.3.1.1.1 | optIfOTSnDirectionality | 0 | 0 | Indicates the directionality of the entity. |
1.3.6.1.2.1.10.133.1.3.1.1.2 | optIfOTSnAprStatus | 0 | 0 | This attribute indicates the status of the Automatic Power Reduction (APR) function of the entity. Valid values are 'on' and 'of… |
1.3.6.1.2.1.10.133.1.3.1.1.4 | optIfOTSnTraceIdentifierTransmitted | 0 | 0 | The trace identifier transmitted. This object is applicable when optIfOTSnDirectionality has the value source(2) or bidirectional… |
1.3.6.1.2.1.10.133.1.3.1.1.5 | optIfOTSnDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(… |
1.3.6.1.2.1.10.133.1.3.1.1.6 | optIfOTSnSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirectional(… |
1.3.6.1.2.1.10.133.1.3.1.1.7 | optIfOTSnTraceIdentifierAccepted | 0 | 0 | The actual trace identifier received. This object is applicable when optIfOTSnDirectionality has the value sink(1) or bidirection… |
1.3.6.1.2.1.10.133.1.3.1.1.8 | optIfOTSnTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is applicable when optIfOTSnDirectiona… |
1.3.6.1.2.1.10.133.1.3.1.1.9 | optIfOTSnTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is applicable when optI… |
1.3.6.1.2.1.10.133.1.3.1.1.10 | optIfOTSnCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. This object is applicable when optIfOTSnDirectionality has the value sink(1… |