The trace identifier transmitted.
This object is applicable when optIfODUkDirectionality
has the value source(2) or bidirectional(3). It must not
be instantiated in rows where optIfODUkDirectionality
has the value sink(1).
If no value is ever set by a management entity for this
object, system-specific default value will be used.
Any implementation that instantiates this object must
document the system-specific default value or how it
is derived.
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
The trace identifier transmitted.
This object is applicable when optIfODUkDirectionality
has the value source(2) or bidirectional(3). It must not
be instantiated in rows where optIfODUkDirectionality
has the value sink(1).
If no value is ever set by a management entity for this
object, system-specific default value will be used.
Any implementation that instantiates this object must
document the system-specific default value or how it
is derived.
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Vendor: IETF RFCs
Module: OPT-IF-MIB (rfc3591-Optical-Interface-Type.mib)
Type: TABULAR
Access: read-write
Syntax: OptIftxTI
Automatically extracted from www.mibdepot.com
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE SYNTAX OptIfTxTI MAX-ACCESS read-write STATUS current DESCRIPTION "The trace identifier transmitted. This object is applicable when optIfODUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value sink(1). If no value is ever set by a management entity for this object, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived." ::= { optIfODUkTtpConfigEntry 1 }
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE SYNTAX OptIfTxTI MAX-ACCESS read-write STATUS current DESCRIPTION "The trace identifier transmitted. This object is applicable when optIfODUkDirectionality has the value source(2) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value sink(1). If no value is ever set by a management entity for this object, system-specific default value will be used. Any implementation that instantiates this object must document the system-specific default value or how it is derived." ::= { optIfODUkTtpConfigEntry 1 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.8.2.1.2 | optIfODUkTtpDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality h… |
1.3.6.1.2.1.10.133.1.8.2.1.3 | optIfODUkTtpSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality h… |
1.3.6.1.2.1.10.133.1.8.2.1.4 | optIfODUkTtpTraceIdentifierAccepted | 0 | 0 | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionalit… |
1.3.6.1.2.1.10.133.1.8.2.1.5 | optIfODUkTtpTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function… |
1.3.6.1.2.1.10.133.1.8.2.1.6 | optIfODUkTtpTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to th… |
1.3.6.1.2.1.10.133.1.8.2.1.7 | optIfODUkTtpDEGThr | 0 | 0 | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the p… |
1.3.6.1.2.1.10.133.1.8.2.1.8 | optIfODUkTtpDEGM | 0 | 0 | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkDEGM consecuti… |
1.3.6.1.2.1.10.133.1.8.2.1.9 | optIfODUkTtpCurrentStatus | 0 | 0 | Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfO… |