optIfODUkTtpCurrentStatus OBJECT-TYPE
SYNTAX BITS {
oci(0),
lck(1),
tim(2),
deg(3),
bdi(4),
ssf(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2)."
View at oid-info.com
Indicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
Parsed from file rfc3591-Optical-Interface-Type.mib.txt
Company: None
Module: OPT-IF-MIB
Indicates the defect condition of the entity, if any.
This object is only applicable to the sink function, i.e.,
only when optIfODUkDirectionality has the value sink(1)
or bidirectional(3). It must not be instantiated in rows
where optIfODUkDirectionality has the value source(2).
Parsed from file OPT-IF-MIB.mib
Module: OPT-IF-MIB
Automatically extracted from RFC3591
optIfODUkTtpCurrentStatus OBJECT-TYPE SYNTAX BITS { oci(0), lck(1), tim(2), deg(3), bdi(4), ssf(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2)." ::= { optIfODUkTtpConfigEntry 9 }
optIfODUkTtpCurrentStatus OBJECT-TYPE SYNTAX BITS { oci(0), lck(1), tim(2), deg(3), bdi(4), ssf(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates the defect condition of the entity, if any. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality has the value sink(1) or bidirectional(3). It must not be instantiated in rows where optIfODUkDirectionality has the value source(2)." ::= { optIfODUkTtpConfigEntry 9 }
Internet Assigned Numbers Authority
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.2.1.10.133.1.8.2.1.1 | optIfODUkTtpTraceIdentifierTransmitted | 0 | 0 | The trace identifier transmitted. This object is applicable when optIfODUkDirectionality has the value source(2) or bidirectional… |
1.3.6.1.2.1.10.133.1.8.2.1.2 | optIfODUkTtpDAPIExpected | 0 | 0 | The DAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality h… |
1.3.6.1.2.1.10.133.1.8.2.1.3 | optIfODUkTtpSAPIExpected | 0 | 0 | The SAPI expected by the receiver. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionality h… |
1.3.6.1.2.1.10.133.1.8.2.1.4 | optIfODUkTtpTraceIdentifierAccepted | 0 | 0 | The actual trace identifier accepted. This object is only applicable to the sink function, i.e., only when optIfODUkDirectionalit… |
1.3.6.1.2.1.10.133.1.8.2.1.5 | optIfODUkTtpTIMDetMode | 0 | 0 | Indicates the mode of the Trace Identifier Mismatch (TIM) Detection function. This object is only applicable to the sink function… |
1.3.6.1.2.1.10.133.1.8.2.1.6 | optIfODUkTtpTIMActEnabled | 0 | 0 | Indicates whether the Trace Identifier Mismatch (TIM) Consequent Action function is enabled. This object is only applicable to th… |
1.3.6.1.2.1.10.133.1.8.2.1.7 | optIfODUkTtpDEGThr | 0 | 0 | Indicates the threshold level for declaring a performance monitoring (PM) Second to be bad. A PM Second is declared bad if the p… |
1.3.6.1.2.1.10.133.1.8.2.1.8 | optIfODUkTtpDEGM | 0 | 0 | Indicates the threshold level for declaring a Degraded Signal defect (dDEG). A dDEG shall be declared if optIfODUkDEGM consecuti… |