The variant identification number for the module which
is installed in the specified slot. If there is no
module installed, the value returned will be zero.
Parsed from file nnci.mib.txt
Company: newbridge
Module: NEWBRIDGE-MIB
Vendor: Newbridge Networks Corporation
Module: NEWBRIDGE-MIB
[Automatically extracted from oidview.com]
nnciSlotVariantID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The variant identification number for the module which is installed in the specified slot. If there is no module installed, the value returned will be zero." ::= {nnciSlotTableEntry 14}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.123.2.10.1.1.1 | nnciSlotName | 0 | 0 | An arbitrary name for a slot. |
1.3.6.1.4.1.123.2.10.1.1.2 | nnciSlotProgType | 0 | 0 | This object is used to specify what kind of module should be present in the specified position . If the value in this object doe… |
1.3.6.1.4.1.123.2.10.1.1.3 | nnciSlotPresType | 0 | 0 | This object is used to specify what kind of module is present in the specified position . If the value of this object does not m… |
1.3.6.1.4.1.123.2.10.1.1.4 | nnciSlotStatus | 0 | 0 | This object contains the current status of the specified position . The status reflects whether a module is present, and if so,… |
1.3.6.1.4.1.123.2.10.1.1.5 | nnciSlotModuleID | 0 | 0 | The hardware identification number assigned to the module that is present in the specified position. If there is no module insta… |
1.3.6.1.4.1.123.2.10.1.1.6 | nnciSlotSubModuleProgType | 0 | 0 | What kind of 'sub-module' should be present in the specified slot. If the value in this object does not match the value in the n… |
1.3.6.1.4.1.123.2.10.1.1.7 | nnciSlotSubModulePresType | 0 | 0 | What kind of 'sub-module' is present in the specified position. If the value of this object does not match the value of the nnciS… |
1.3.6.1.4.1.123.2.10.1.1.8 | nnciSlotFirmwareID | 0 | 0 | The revision level of the firmware, if any, that is present on a module. If no firmware is present, the value will be zero. |
1.3.6.1.4.1.123.2.10.1.1.9 | nnciSlotBusyOut | 0 | 0 | This object is used to take circuits on a specified slot out of service. If the value of this object is hold-out-of-service, the… |
1.3.6.1.4.1.123.2.10.1.1.10 | nnciSlotSubModuleID | 0 | 0 | The hardware identification number assigned to the sub-module that is present in the specified position. If there is no sub-modul… |
1.3.6.1.4.1.123.2.10.1.1.15 | nnciSlotResetCard | 0 | 0 | This object is used to cause the node to re-initialize the specified module. Any set to this object will cause the specified mod… |
1.3.6.1.4.1.123.2.10.1.1.19 | nnciSlotHardwareRevision | 0 | 0 | The engineering revision level of the module that occupies the specified position. The high nibble of the returned value is the m… |