Reference record for OID 1.3.6.1.4.1.123.2.10.1.1.19



parent
1.3.6.1.4.1.123.2.10.1.1 (nnciSlotTableEntry)
node code
19
node name
nnciSlotHardwareRevision
dot oid
1.3.6.1.4.1.123.2.10.1.1.19
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotHardwareRevision(19)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotHardwareRevision(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotHardwareRevision(19)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotHardwareRevision(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotHardwareRevision(19)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotHardwareRevision(19)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotHardwareRevision
  • /iso/identified-organization/dod/internet/private/enterprises/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotHardwareRevision
  • /iso/org/dod/internet/private/enterprise/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotHardwareRevision
  • /iso/org/dod/internet/private/enterprises/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotHardwareRevision
  • /iso/iso-identified-organization/dod/internet/private/enterprise/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotHardwareRevision
  • /iso/iso-identified-organization/dod/internet/private/enterprises/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotHardwareRevision
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/123/2/10/1/1/19

    Description by mibdepot

    The engineering revision level of the module that
    occupies the specified position. The high nibble of the
    returned value is the major revision level and the low
    nibble is the minor revision, e.g. Engineering Revision
    21 will be returned as $21.

    Parsed from file nnci.mib.txt
    Company: newbridge
    Module: NEWBRIDGE-MIB

    Information by oid_info

    Vendor: Newbridge Networks Corporation
    Module: NEWBRIDGE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    nnciSlotHardwareRevision OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The engineering revision level of the module that occupies the specified position. The high nibble of the returned value is the major revision level and the low nibble is the minor revision, e.g. Engineering Revision 21 will be returned as $21." ::= {nnciSlotTableEntry 19}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.123)

    Watt James

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.123.2.10.1.1.1 nnciSlotName 0 0 An arbitrary name for a slot.
    1.3.6.1.4.1.123.2.10.1.1.2 nnciSlotProgType 0 0 This object is used to specify what kind of module
    should be present in the specified position . If the
    value in this object doe…
    1.3.6.1.4.1.123.2.10.1.1.3 nnciSlotPresType 0 0 This object is used to specify what kind of module is
    present in the specified position . If the value of
    this object does not m…
    1.3.6.1.4.1.123.2.10.1.1.4 nnciSlotStatus 0 0 This object contains the current status of the
    specified position . The status reflects whether a
    module is present, and if so,…
    1.3.6.1.4.1.123.2.10.1.1.5 nnciSlotModuleID 0 0 The hardware identification number assigned to the
    module that is present in the specified position. If
    there is no module insta…
    1.3.6.1.4.1.123.2.10.1.1.6 nnciSlotSubModuleProgType 0 0 What kind of 'sub-module' should be present in the
    specified slot. If the value in this object does not
    match the value in the n…
    1.3.6.1.4.1.123.2.10.1.1.7 nnciSlotSubModulePresType 0 0 What kind of 'sub-module' is present in the specified
    position. If the value of this object does not match the
    value of the nnciS…
    1.3.6.1.4.1.123.2.10.1.1.8 nnciSlotFirmwareID 0 0 The revision level of the firmware, if any, that is
    present on a module. If no firmware is present, the
    value will be zero.
    1.3.6.1.4.1.123.2.10.1.1.9 nnciSlotBusyOut 0 0 This object is used to take circuits on a specified
    slot out of service. If the value of this object is
    hold-out-of-service, the…
    1.3.6.1.4.1.123.2.10.1.1.10 nnciSlotSubModuleID 0 0 The hardware identification number assigned to the
    sub-module that is present in the specified position.
    If there is no sub-modul…
    1.3.6.1.4.1.123.2.10.1.1.14 nnciSlotVariantID 0 0 The variant identification number for the module which
    is installed in the specified slot. If there is no
    module installed, the …
    1.3.6.1.4.1.123.2.10.1.1.15 nnciSlotResetCard 0 0 This object is used to cause the node to re-initialize
    the specified module. Any set to this object will cause
    the specified mod…