Reference record for OID 1.3.6.1.4.1.123.2.10.1.1.4



parent
1.3.6.1.4.1.123.2.10.1.1 (nnciSlotTableEntry)
node code
4
node name
nnciSlotStatus
dot oid
1.3.6.1.4.1.123.2.10.1.1.4
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotStatus(4)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotStatus(4)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotStatus(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotStatus(4)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncInterimMib(2) nnciSlot(10) nnciSlotTable(1) nnciSlotTableEntry(1) nnciSlotStatus(4)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotStatus
  • /iso/identified-organization/dod/internet/private/enterprises/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotStatus
  • /iso/org/dod/internet/private/enterprise/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotStatus
  • /iso/org/dod/internet/private/enterprises/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprise/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotStatus
  • /iso/iso-identified-organization/dod/internet/private/enterprises/newbridge/nncInterimMib/nnciSlot/nnciSlotTable/nnciSlotTableEntry/nnciSlotStatus
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/123/2/10/1/1/4

    Description by mibdepot

    This object contains the current status of the
    specified position . The status reflects whether a
    module is present, and if so, is it of the expected
    type.

    Parsed from file nnci.mib.txt
    Company: newbridge
    Module: NEWBRIDGE-MIB

    Information by oid_info

    Vendor: Newbridge Networks Corporation
    Module: NEWBRIDGE-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    nnciSlotStatus OBJECT-TYPE SYNTAX INTEGER { empty(1), ok(2), fault-on-module(3), module-dead(4), unknown-module-type(5), module-type-mismatch(6), sub-module-type-mismatch(7), wrong-firmware(9), wrong-variant(12)} ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the current status of the specified position . The status reflects whether a module is present, and if so, is it of the expected type." ::= {nnciSlotTableEntry 4}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.123)

    Watt James

    Brothers (12)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.123.2.10.1.1.1 nnciSlotName 0 0 An arbitrary name for a slot.
    1.3.6.1.4.1.123.2.10.1.1.2 nnciSlotProgType 0 0 This object is used to specify what kind of module
    should be present in the specified position . If the
    value in this object doe…
    1.3.6.1.4.1.123.2.10.1.1.3 nnciSlotPresType 0 0 This object is used to specify what kind of module is
    present in the specified position . If the value of
    this object does not m…
    1.3.6.1.4.1.123.2.10.1.1.5 nnciSlotModuleID 0 0 The hardware identification number assigned to the
    module that is present in the specified position. If
    there is no module insta…
    1.3.6.1.4.1.123.2.10.1.1.6 nnciSlotSubModuleProgType 0 0 What kind of 'sub-module' should be present in the
    specified slot. If the value in this object does not
    match the value in the n…
    1.3.6.1.4.1.123.2.10.1.1.7 nnciSlotSubModulePresType 0 0 What kind of 'sub-module' is present in the specified
    position. If the value of this object does not match the
    value of the nnciS…
    1.3.6.1.4.1.123.2.10.1.1.8 nnciSlotFirmwareID 0 0 The revision level of the firmware, if any, that is
    present on a module. If no firmware is present, the
    value will be zero.
    1.3.6.1.4.1.123.2.10.1.1.9 nnciSlotBusyOut 0 0 This object is used to take circuits on a specified
    slot out of service. If the value of this object is
    hold-out-of-service, the…
    1.3.6.1.4.1.123.2.10.1.1.10 nnciSlotSubModuleID 0 0 The hardware identification number assigned to the
    sub-module that is present in the specified position.
    If there is no sub-modul…
    1.3.6.1.4.1.123.2.10.1.1.14 nnciSlotVariantID 0 0 The variant identification number for the module which
    is installed in the specified slot. If there is no
    module installed, the …
    1.3.6.1.4.1.123.2.10.1.1.15 nnciSlotResetCard 0 0 This object is used to cause the node to re-initialize
    the specified module. Any set to this object will cause
    the specified mod…
    1.3.6.1.4.1.123.2.10.1.1.19 nnciSlotHardwareRevision 0 0 The engineering revision level of the module that
    occupies the specified position. The high nibble of the
    returned value is the m…