This object contains the current status of the
specified position . The status reflects whether a
module is present, and if so, is it of the expected
type.
Parsed from file nnci.mib.txt
Company: newbridge
Module: NEWBRIDGE-MIB
Vendor: Newbridge Networks Corporation
Module: NEWBRIDGE-MIB
[Automatically extracted from oidview.com]
nnciSlotStatus OBJECT-TYPE SYNTAX INTEGER { empty(1), ok(2), fault-on-module(3), module-dead(4), unknown-module-type(5), module-type-mismatch(6), sub-module-type-mismatch(7), wrong-firmware(9), wrong-variant(12)} ACCESS read-write STATUS mandatory DESCRIPTION "This object contains the current status of the specified position . The status reflects whether a module is present, and if so, is it of the expected type." ::= {nnciSlotTableEntry 4}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.123.2.10.1.1.1 | nnciSlotName | 0 | 0 | An arbitrary name for a slot. |
1.3.6.1.4.1.123.2.10.1.1.2 | nnciSlotProgType | 0 | 0 | This object is used to specify what kind of module should be present in the specified position . If the value in this object doe… |
1.3.6.1.4.1.123.2.10.1.1.3 | nnciSlotPresType | 0 | 0 | This object is used to specify what kind of module is present in the specified position . If the value of this object does not m… |
1.3.6.1.4.1.123.2.10.1.1.5 | nnciSlotModuleID | 0 | 0 | The hardware identification number assigned to the module that is present in the specified position. If there is no module insta… |
1.3.6.1.4.1.123.2.10.1.1.6 | nnciSlotSubModuleProgType | 0 | 0 | What kind of 'sub-module' should be present in the specified slot. If the value in this object does not match the value in the n… |
1.3.6.1.4.1.123.2.10.1.1.7 | nnciSlotSubModulePresType | 0 | 0 | What kind of 'sub-module' is present in the specified position. If the value of this object does not match the value of the nnciS… |
1.3.6.1.4.1.123.2.10.1.1.8 | nnciSlotFirmwareID | 0 | 0 | The revision level of the firmware, if any, that is present on a module. If no firmware is present, the value will be zero. |
1.3.6.1.4.1.123.2.10.1.1.9 | nnciSlotBusyOut | 0 | 0 | This object is used to take circuits on a specified slot out of service. If the value of this object is hold-out-of-service, the… |
1.3.6.1.4.1.123.2.10.1.1.10 | nnciSlotSubModuleID | 0 | 0 | The hardware identification number assigned to the sub-module that is present in the specified position. If there is no sub-modul… |
1.3.6.1.4.1.123.2.10.1.1.14 | nnciSlotVariantID | 0 | 0 | The variant identification number for the module which is installed in the specified slot. If there is no module installed, the … |
1.3.6.1.4.1.123.2.10.1.1.15 | nnciSlotResetCard | 0 | 0 | This object is used to cause the node to re-initialize the specified module. Any set to this object will cause the specified mod… |
1.3.6.1.4.1.123.2.10.1.1.19 | nnciSlotHardwareRevision | 0 | 0 | The engineering revision level of the module that occupies the specified position. The high nibble of the returned value is the m… |