Reference record for OID 1.3.6.1.4.1.123.3.82.1.5.1.2



parent
1.3.6.1.4.1.123.3.82.1.5.1 (nncFrSpvcTableEntry)
node code
2
node name
nncFrSpvcTargEpAddr
dot oid
1.3.6.1.4.1.123.3.82.1.5.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncExtensions(3) nncExtSpvc(82) nncExtSpvcObjects(1) nncFrSpvcTable(5) nncFrSpvcTableEntry(1) nncFrSpvcTargEpAddr(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncExtensions(3) nncExtSpvc(82) nncExtSpvcObjects(1) nncFrSpvcTable(5) nncFrSpvcTableEntry(1) nncFrSpvcTargEpAddr(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncExtensions(3) nncExtSpvc(82) nncExtSpvcObjects(1) nncFrSpvcTable(5) nncFrSpvcTableEntry(1) nncFrSpvcTargEpAddr(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncExtensions(3) nncExtSpvc(82) nncExtSpvcObjects(1) nncFrSpvcTable(5) nncFrSpvcTableEntry(1) nncFrSpvcTargEpAddr(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) newbridge(123) nncExtensions(3) nncExtSpvc(82) nncExtSpvcObjects(1) nncFrSpvcTable(5) nncFrSpvcTableEntry(1) nncFrSpvcTargEpAddr(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) newbridge(123) nncExtensions(3) nncExtSpvc(82) nncExtSpvcObjects(1) nncFrSpvcTable(5) nncFrSpvcTableEntry(1) nncFrSpvcTargEpAddr(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/newbridge/nncExtensions/nncExtSpvc/nncExtSpvcObjects/nncFrSpvcTable/nncFrSpvcTableEntry/nncFrSpvcTargEpAddr
  • /iso/identified-organization/dod/internet/private/enterprises/newbridge/nncExtensions/nncExtSpvc/nncExtSpvcObjects/nncFrSpvcTable/nncFrSpvcTableEntry/nncFrSpvcTargEpAddr
  • /iso/org/dod/internet/private/enterprise/newbridge/nncExtensions/nncExtSpvc/nncExtSpvcObjects/nncFrSpvcTable/nncFrSpvcTableEntry/nncFrSpvcTargEpAddr
  • /iso/org/dod/internet/private/enterprises/newbridge/nncExtensions/nncExtSpvc/nncExtSpvcObjects/nncFrSpvcTable/nncFrSpvcTableEntry/nncFrSpvcTargEpAddr
  • /iso/iso-identified-organization/dod/internet/private/enterprise/newbridge/nncExtensions/nncExtSpvc/nncExtSpvcObjects/nncFrSpvcTable/nncFrSpvcTableEntry/nncFrSpvcTargEpAddr
  • /iso/iso-identified-organization/dod/internet/private/enterprises/newbridge/nncExtensions/nncExtSpvc/nncExtSpvcObjects/nncFrSpvcTable/nncFrSpvcTableEntry/nncFrSpvcTargEpAddr
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/123/3/82/1/5/1/2

    Description by mibdepot

    This object contains the target endpoint's 20-byte ATM End System
    Address (AESA) proposed by ATM Forum. An endpoint address is created
    by appending the switch-wide 13-byte Internal Switch Subscriber
    Address Prefix with a 6-byte End Station Identifier (ESI) followed by
    a selector byte. The ESI is in IEEE MAC address format and the exact
    form depends upon the destination endpoint and the SPVC commissioning
    method. The mapping scheme is as follows:

    Byte\Bit 8 7 6 5 4 3 2 1

    1-13 byte | 13-byte Internal Subscriber Prefix |

    14th byte | I/G | U/L | OUI(most significant 6 bits) |

    15th byte | OUI(2nd most significant 8 bits |

    16th byte | OUI(3rd most significant 8 bits |

    17th byte | Shelf/Slot(1st most significant 8 bits |

    18th byte | Shelf/Slot(2nd most significant 8 bits |

    19th byte |Flag1| Port | Circuit |

    20th byte |Circuit(continued) | Stream |

    Parsed from file NncExtSPVC.mib.txt
    Company: None
    Module: NNCEXTSPVC-MIB

    Description by circitor

    This object contains the target endpoint's 20-byte ATM End System
    Address (AESA) proposed by ATM Forum. An endpoint address is created
    by appending the switch-wide 13-byte Internal Switch Subscriber
    Address Prefix with a 6-byte End Station Identifier (ESI) followed by
    a selector byte. The ESI is in IEEE MAC address format and the exact
    form depends upon the destination endpoint and the SPVC commissioning
    method. The mapping scheme is as follows:

    Byte\Bit 8 7 6 5 4 3 2 1

    1-13 byte | 13-byte Internal Subscriber Prefix |

    14th byte | I/G | U/L | OUI(most significant 6 bits) |

    15th byte | OUI(2nd most significant 8 bits |

    16th byte | OUI(3rd most significant 8 bits |

    17th byte | Shelf/Slot(1st most significant 8 bits |

    18th byte | Shelf/Slot(2nd most significant 8 bits |

    19th byte |Flag1| Port | Circuit |

    20th byte |Circuit(continued) | Stream |

    Parsed from file NNCEXTSPVC-MIB.mib
    Module: NNCEXTSPVC-MIB

    Information by oid_info

    Vendor: Newbridge Networks Corporation
    Module: NNCEXTSPVC-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    nncFrSpvcTargEpAddr OBJECT-TYPE SYNTAX AtmFormatDisplay MAX-ACCESS read-create STATUS current DESCRIPTION "This object contains the target endpoint's 20-byte ATM End System Address (AESA) proposed by ATM Forum. An endpoint address is created by appending the switch-wide 13-byte Internal Switch Subscriber Address Prefix with a 6-byte End Station Identifier (ESI) followed by a selector byte. The ESI is in IEEE MAC address format and the exact form depends upon the destination endpoint and the SPVC commissioning method. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 1-13 byte | 13-byte Internal Subscriber Prefix | 14th byte | I/G | U/L | OUI(most significant 6 bits) | 15th byte | OUI(2nd most significant 8 bits | 16th byte | OUI(3rd most significant 8 bits | 17th byte | Shelf/Slot(1st most significant 8 bits | 18th byte | Shelf/Slot(2nd most significant 8 bits | 19th byte |Flag1| Port | Circuit | 20th byte |Circuit(continued) | Stream | " ::= { nncFrSpvcTableEntry 2 }

    Information by circitor

    nncFrSpvcTargEpAddr OBJECT-TYPE SYNTAX AtmFormatDisplay MAX-ACCESS read-create STATUS current DESCRIPTION "This object contains the target endpoint's 20-byte ATM End System Address (AESA) proposed by ATM Forum. An endpoint address is created by appending the switch-wide 13-byte Internal Switch Subscriber Address Prefix with a 6-byte End Station Identifier (ESI) followed by a selector byte. The ESI is in IEEE MAC address format and the exact form depends upon the destination endpoint and the SPVC commissioning method. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 1-13 byte | 13-byte Internal Subscriber Prefix | 14th byte | I/G | U/L | OUI(most significant 6 bits) | 15th byte | OUI(2nd most significant 8 bits | 16th byte | OUI(3rd most significant 8 bits | 17th byte | Shelf/Slot(1st most significant 8 bits | 18th byte | Shelf/Slot(2nd most significant 8 bits | 19th byte |Flag1| Port | Circuit | 20th byte |Circuit(continued) | Stream | " ::= { nncFrSpvcTableEntry 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.123)

    Watt James

    Brothers (48)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.123.3.82.1.5.1.1 nncFrSpvcSrcDlci 0 0 This object contains the data link connection identifier for a frame relay
    endpoint. This number is used to identify the source…
    1.3.6.1.4.1.123.3.82.1.5.1.3 nncFrSpvcTargDlci 0 0 This object contains the data link connection identifier for a frame relay
    endpoint. This number is used to identify the target…
    1.3.6.1.4.1.123.3.82.1.5.1.4 nncFrSpvcTargVpi 0 0 This object contains the virtual path identifier (VPI) value for the
    Cell Relay based target endpoint. Range: 0 - 4095
    1.3.6.1.4.1.123.3.82.1.5.1.5 nncFrSpvcTargVci 0 0 This object contains the virtual channel identifier (VCI) value for the
    cell-relay based target endpoint. Range: 1 - 65535
    1.3.6.1.4.1.123.3.82.1.5.1.6 nncFrSpvcTargEpType 0 0 This object specifies a target endpoint
    as one of the following types:
    cellRelay (1)
    frameRelay (2)
    1.3.6.1.4.1.123.3.82.1.5.1.7 nncFrSpvcAdminStatus 0 0 This object accepts two values, enabled (1), and disabled (2).
    When the value is disabled, the SPVC is not connected. When
    enabl…
    1.3.6.1.4.1.123.3.82.1.5.1.8 nncFrSpvcPriority 0 0 This object is used to set the priority for a SPVC connection
    request. It ranges between 1-16, with the following values:
    Best Pr…
    1.3.6.1.4.1.123.3.82.1.5.1.9 nncFrSpvcMaxAdminWeight 0 0 This object is used to set a cost threshold for an SPVC connection.
    If the total cost of all VPCs exceeds this weight value for …
    1.3.6.1.4.1.123.3.82.1.5.1.10 nncFrSpvcOperation 0 0 This object is used to request a reroute operation. Querying this
    object will not provide any useful information.
    1.3.6.1.4.1.123.3.82.1.5.1.11 nncFrSpvcCallStatus 0 0 This read-only object is used to query the state of a particular SPVC.
    SPVCs that are connected and operational will return a va…
    1.3.6.1.4.1.123.3.82.1.5.1.12 nncFrSpvcLocRerouteConfig 0 0 This object is used to configure the 'reroute on loss of continuity'
    feature using OAM-CC cells. It can be configured for eithe…
    1.3.6.1.4.1.123.3.82.1.5.1.13 nncFrSpvcSrcBillingFlag 0 0 Billing Configuration for the source endpoint.
    1.3.6.1.4.1.123.3.82.1.5.1.14 nncFrSpvcFrPriority 0 0 Frame Relay Priority.
    1.3.6.1.4.1.123.3.82.1.5.1.15 nncFrSpvcFrVsvdCongestionControl 0 0 Congestion Control for VS/VD endpoints,
    also known as Closed Loop Congestion
    Control (CLCC).
    1.3.6.1.4.1.123.3.82.1.5.1.16 nncFrSpvcFwdFrMir 0 0 The FR Src->Dst Minimum Information Rate,
    used to set the minimum rate on a CLCC FR-FR
    SPVC connection.
    If nncFrSpvcFrVsvdCongesti…
    1.3.6.1.4.1.123.3.82.1.5.1.17 nncFrSpvcFwdTmAr 0 0 This object is used to specify the Access Rate, in Kb/s
    1.3.6.1.4.1.123.3.82.1.5.1.18 nncFrSpvcFwdTmCir 0 0 The committed Information Rate, in Kb/s
    1.3.6.1.4.1.123.3.82.1.5.1.19 nncFrSpvcFwdTmBc 0 0 The Committed Burst Size, in Kb.
    1.3.6.1.4.1.123.3.82.1.5.1.20 nncFrSpvcFwdTmBe 0 0 Excess Burst Size, Kb.
    1.3.6.1.4.1.123.3.82.1.5.1.21 nncFrSpvcTmIwf 0 0 Interworking Function. Values:
    none (None (FR Switching) = 0)
    networkInterworking (Network Interworking = 2)…
    1.3.6.1.4.1.123.3.82.1.5.1.22 nncFrSpvcFwdTmPo 0 0 Policing.
    1.3.6.1.4.1.123.3.82.1.5.1.23 nncFrSpvcFwdTmPacing 0 0 Pacing.
    1.3.6.1.4.1.123.3.82.1.5.1.24 nncFrSpvcTmPtclMapping 0 0 Protocol Mapping for Service Interworking SPVCs.
    If Translated Service Interworking is selected,
    the a profile must be set using …
    1.3.6.1.4.1.123.3.82.1.5.1.25 nncFrSpvcTmClpMapping 0 0 Cell Loss Priority Mapping, for use in FR-CR interworking
    SPVCs.
    Values:
    cLPEqualsDE (CLP = DE, 0)
    cLPEquals0 (CLP = 0, 1 )
    cLPEqu…
    1.3.6.1.4.1.123.3.82.1.5.1.26 nncFrSpvcTmDeMapping 0 0 Discard Eligibility Mapping, for use in FR-CR interworking
    SPVCs.
    Values:
    dEEqualsCLP (DE = CLP, 0)
    dESSCSor0 (Network Interwo…
    1.3.6.1.4.1.123.3.82.1.5.1.27 nncFrSpvcTmEfciMapping 0 0 Explicit Forward Congestion Indication Mapping
    (Applies only to Service Interworking (IWF3), FR to ATM)
    Values:
    eFCIEqualsFECN (EF…
    1.3.6.1.4.1.123.3.82.1.5.1.28 nncFrSpvcTmPvcMgntProfile 0 0 Enables or disables the PVC Management Profile.
    When enabled, LMI is enabled on the network-side
    of the connection.
    Used only with…
    1.3.6.1.4.1.123.3.82.1.5.1.29 nncFrSpvcTmSIWProfile 0 0 The FR-CR profile index for service interworking connections.
    This attribute is used to define the translation profile
    to use whe…
    1.3.6.1.4.1.123.3.82.1.5.1.30 nncFrSpvcTmRemapDlci 0 0 The source end-point Data Link Connection Identifier
    for many-to-one Network Interworking (IWF2) connections.
    1.3.6.1.4.1.123.3.82.1.5.1.31 nncFrSpvcBwdFrMir 0 0 The FR Dst->Src Minimum Information Rate, used
    on CLCC-enabled connections.
    Range: 0 - 44210 Kb/s
    1.3.6.1.4.1.123.3.82.1.5.1.32 nncFrSpvcBwdTmAr 0 0 This object is used to specify the Access Rate, in Kb/s
    1.3.6.1.4.1.123.3.82.1.5.1.33 nncFrSpvcBwdTmCir 0 0 The committed Information Rate, in Kb/s
    1.3.6.1.4.1.123.3.82.1.5.1.34 nncFrSpvcBwdTmBc 0 0 The Committed Burst Size, in Kb.
    1.3.6.1.4.1.123.3.82.1.5.1.35 nncFrSpvcBwdTmBe 0 0 The Excess Burst Size, Kb.
    1.3.6.1.4.1.123.3.82.1.5.1.36 nncFrSpvcBwdTmPo 0 0 Policing.
    1.3.6.1.4.1.123.3.82.1.5.1.37 nncFrSpvcBwdTmPacing 0 0 Pacing.
    1.3.6.1.4.1.123.3.82.1.5.1.38 nncFrSpvcCrTmServiceCategory 0 0 This object is used to set the traffic service category for SPVC
    Connections. This object is dependent on the value specified i…
    1.3.6.1.4.1.123.3.82.1.5.1.39 nncFrSpvcCrBwdTmTrafficDescriptor 0 0 This object contains the CR traffic descriptor for a FR-CR SPVC.
    Tag All (1) (UBR using 2k/12k fabric only)
    P_0+1/S_0+1 …
    1.3.6.1.4.1.123.3.82.1.5.1.40 nncFrSpvcCrBwdTmPolicingOption 0 0 Policing Option for a FR SPVC.
    tag is supported only on rt-VBR/nrt-VBR connections that use the
    P_0+1/S_0 traffic descriptor
    1.3.6.1.4.1.123.3.82.1.5.1.41 nncFrSpvcCrBwdTmBucketOneRate 0 0 Used in FR - CR interworking.
    This object is for peak cell rate (PCR), the
    cell rate which the cell endpoint may never exceed. I…
    1.3.6.1.4.1.123.3.82.1.5.1.42 nncFrSpvcCrBwdTmBucketOneCdvt 0 0 This object is used to set cell delay variation tolerance (CDVT) for
    the CR endpoint, measured in microseconds.
    Range: 1 - 190,00…
    1.3.6.1.4.1.123.3.82.1.5.1.43 nncFrSpvcCrBwdTmBucketTwoRate 0 0 Used in FR - CR interworking.
    The attribute contains the SIR_0, SIR_0+1 or MIR_0+1.
    This parameter holds the sustained informatio…
    1.3.6.1.4.1.123.3.82.1.5.1.44 nncFrSpvcCrBwdTmBucketTwoMbs 0 0 This object is for the maximum burst size, in cells,
    for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only).
    Range: 1 - 10000 cells
    1.3.6.1.4.1.123.3.82.1.5.1.45 nncFrSpvcCrBwdTmCdv 0 0 This value is to set the cell delay variation (CDV) at the CR
    endpoint. Applicable only when the rt-VBR service category is use…
    1.3.6.1.4.1.123.3.82.1.5.1.46 nncFrSpvcCrBwdTmClr 0 0 The object is to set the cell loss ratio (CLR) at the CR endpoint of
    a FR-CR SPVC. Valid only when using the nrt-VBR service ca…
    1.3.6.1.4.1.123.3.82.1.5.1.47 nncFrSpvcCrBwdTmFrameDiscard 0 0 The Frame (AAL protocol data unit) Discard option. When enabled,
    cells are discarded at the frame level by examining the SDU-ty…
    1.3.6.1.4.1.123.3.82.1.5.1.48 nncFrSpvcCreator 0 0 The object retrieves the creator of a given SPVC connection.
    1.3.6.1.4.1.123.3.82.1.5.1.49 nncFrSpvcRowStatus 0 0 This object is used to control the status of a PDU and to query
    the status of an SPVC. When the RowStatus value is 'createAndWa…