Setting this attribute to on, clears all the running loops
and tests of the DTE port. Upon completion, the value will
automatically change to off(2).
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
Setting this attribute to on, clears all the running loops
and tests of the DTE port. Upon completion, the value will
automatically change to off(2).
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications
Module: RAD-MIB (rad-mib.mib)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
modmPrtDteClearAllTests OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the running loops and tests of the DTE port. Upon completion, the value will automatically change to off(2)." ::= {modmPrtDteEntry 16}
modmPrtDteClearAllTests OBJECT-TYPE SYNTAX INTEGER { off(2), on (3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Setting this attribute to on, clears all the running loops and tests of the DTE port. Upon completion, the value will automatically change to off(2)." ::= {modmPrtDteEntry 16}
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.3.4.4.4.1.1.1 | modmPrtDteIndex | 0 | 0 | The DTE port index. |
1.3.6.1.4.1.164.3.4.4.4.1.1.2 | modmPrtDteProtocol | 0 | 0 | The DTE port Protocol. |
1.3.6.1.4.1.164.3.4.4.4.1.1.3 | modmPrtDteDataBits | 0 | 0 | The DTE number of data bits. |
1.3.6.1.4.1.164.3.4.4.4.1.1.4 | modmPrtDteStopBits | 0 | 0 | The DTE minimum number of stop bits in the tx async frame. |
1.3.6.1.4.1.164.3.4.4.4.1.1.5 | modmPrtDteRate | 0 | 0 | The DTE port rate. |
1.3.6.1.4.1.164.3.4.4.4.1.1.6 | modmPrtDteCtsDelay | 0 | 0 | CTS/RTS delay, in msec. dxx = xx msec. notApplicable - for ASMi-31, ASMi-32. |
1.3.6.1.4.1.164.3.4.4.4.1.1.7 | modmPrtDteParity | 0 | 0 | This attribute indicates the parity mode in async frame. |
1.3.6.1.4.1.164.3.4.4.4.1.1.8 | modmPrtDteIfType | 0 | 0 | modmPrtDteIftype |
1.3.6.1.4.1.164.3.4.4.4.1.1.9 | modmPrtDteRlbEnable | 0 | 0 | Enable/Disable Remote Loop-Back on this modem, externally initiated. |
1.3.6.1.4.1.164.3.4.4.4.1.1.10 | modmPrtDteAlbEnable | 0 | 0 | Enable/Disable Analog Loop-Back on this modem, externally initiated. |
1.3.6.1.4.1.164.3.4.4.4.1.1.11 | modmPrtDteRtsDcdEnable | 0 | 0 | Enable/Disable RTS-DCD. |
1.3.6.1.4.1.164.3.4.4.4.1.1.12 | modmPrtDteDsrDtrEnable | 0 | 0 | Enable/Disable DSR-DTR. |
1.3.6.1.4.1.164.3.4.4.4.1.1.13 | modmPrtDteSignaling | 0 | 0 | Each bit represents a specific signal state. 1 - means : signal is ON , Enabled, Yes (exists) 0 - means : signal is OFF, Disabled… |
1.3.6.1.4.1.164.3.4.4.4.1.1.14 | modmPrtDteLoops | 0 | 0 | Loops that can be run on the DTE port. none - no loop (stop running loop) ana - Local Analog Line loop rem - Remote Analog Line … |
1.3.6.1.4.1.164.3.4.4.4.1.1.15 | modmPrtDteTests | 0 | 0 | This is a mask which indicates - for Get: which tests are running on the DTE port. - for Set: tests the user wishes to start or s… |
1.3.6.1.4.1.164.3.4.4.4.1.1.17 | modmPrtDteBertResult | 0 | 0 | Result of BERT for the selected DTE port. Applicable only if BERT is running on the DTE port. |
1.3.6.1.4.1.164.3.4.4.4.1.1.18 | modmPrtDteErrCorrect | 0 | 0 | notApplicable - for modems that do not support this object on - will start a random error correction process. onBurst - will… |
1.3.6.1.4.1.164.3.4.4.4.1.1.19 | modmPrtDteV54DigitalTest | 0 | 0 | Enables to start a remote digital loopback upon recognition of a special pattern. disable - will not start a digital loopback wh… |
1.3.6.1.4.1.164.3.4.4.4.1.1.20 | modmPrtDteV54DigitalTestStatus | 0 | 0 | Indicates whether a remote digital test was triggered by a pattern by the remote modem or not. no - the digital test wasn't trig… |
1.3.6.1.4.1.164.3.4.4.4.1.1.21 | modmPrtDteTestTimeOut | 0 | 0 | Indicates the timeout for LLB test. 0=Forever |