Reference record for OID 1.3.6.1.4.1.164.3.4.4.4.1.1.18



parent
1.3.6.1.4.1.164.3.4.4.4.1.1 (modmPrtDteEntry)
node code
18
node name
modmPrtDteErrCorrect
dot oid
1.3.6.1.4.1.164.3.4.4.4.1.1.18
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) modmSys(4) modmPrt(4) modmDtePort(4) modmPrtDteTable(1) modmPrtDteEntry(1) modmPrtDteErrCorrect(18)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) modmSys(4) modmPrt(4) modmDtePort(4) modmPrtDteTable(1) modmPrtDteEntry(1) modmPrtDteErrCorrect(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) modmSys(4) modmPrt(4) modmDtePort(4) modmPrtDteTable(1) modmPrtDteEntry(1) modmPrtDteErrCorrect(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) modmSys(4) modmPrt(4) modmDtePort(4) modmPrtDteTable(1) modmPrtDteEntry(1) modmPrtDteErrCorrect(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radWan(3) modmSys(4) modmPrt(4) modmDtePort(4) modmPrtDteTable(1) modmPrtDteEntry(1) modmPrtDteErrCorrect(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radWan(3) modmSys(4) modmPrt(4) modmDtePort(4) modmPrtDteTable(1) modmPrtDteEntry(1) modmPrtDteErrCorrect(18)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/rad/radWan/modmSys/modmPrt/modmDtePort/modmPrtDteTable/modmPrtDteEntry/modmPrtDteErrCorrect
  • /iso/identified-organization/dod/internet/private/enterprises/rad/radWan/modmSys/modmPrt/modmDtePort/modmPrtDteTable/modmPrtDteEntry/modmPrtDteErrCorrect
  • /iso/org/dod/internet/private/enterprise/rad/radWan/modmSys/modmPrt/modmDtePort/modmPrtDteTable/modmPrtDteEntry/modmPrtDteErrCorrect
  • /iso/org/dod/internet/private/enterprises/rad/radWan/modmSys/modmPrt/modmDtePort/modmPrtDteTable/modmPrtDteEntry/modmPrtDteErrCorrect
  • /iso/iso-identified-organization/dod/internet/private/enterprise/rad/radWan/modmSys/modmPrt/modmDtePort/modmPrtDteTable/modmPrtDteEntry/modmPrtDteErrCorrect
  • /iso/iso-identified-organization/dod/internet/private/enterprises/rad/radWan/modmSys/modmPrt/modmDtePort/modmPrtDteTable/modmPrtDteEntry/modmPrtDteErrCorrect
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/164/3/4/4/4/1/1/18

    Description by mibdepot

    notApplicable - for modems that do not support this object
    on - will start a random error correction process.
    onBurst - will start a burst error correction process.
    Setting this object to 'off', will stop any kind of error correction process.

    Parsed from file Rad0485.MIB.txt
    Company: None
    Module: RAD-MIB

    Description by circitor

    notApplicable - for modems that do not support this object
    on - will start a random error correction process.
    onBurst - will start a burst error correction process.
    Setting this object to 'off', will stop any kind of error correction process.

    Parsed from file RAD-MIB.mib
    Module: RAD-MIB

    Information by oid_info

    Vendor: Rad Data Communications
    Module: RAD-MIB (rad-mib.mib)
    Type: TABULAR
    Access: read-write
    Syntax: INTEGER

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    modmPrtDteErrCorrect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3), onBurst (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "notApplicable - for modems that do not support this object on - will start a random error correction process. onBurst - will start a burst error correction process. Setting this object to 'off', will stop any kind of error correction process." ::= {modmPrtDteEntry 18}

    Information by circitor

    modmPrtDteErrCorrect OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), off (2), on (3), onBurst (4) } MAX-ACCESS read-write STATUS current DESCRIPTION "notApplicable - for modems that do not support this object on - will start a random error correction process. onBurst - will start a burst error correction process. Setting this object to 'off', will stop any kind of error correction process." ::= {modmPrtDteEntry 18}

    First Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Brighitte Shalom

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Smadar Tauber

    Brothers (20)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.164.3.4.4.4.1.1.1 modmPrtDteIndex 0 0 The DTE port index.
    1.3.6.1.4.1.164.3.4.4.4.1.1.2 modmPrtDteProtocol 0 0 The DTE port Protocol.
    1.3.6.1.4.1.164.3.4.4.4.1.1.3 modmPrtDteDataBits 0 0 The DTE number of data bits.
    1.3.6.1.4.1.164.3.4.4.4.1.1.4 modmPrtDteStopBits 0 0 The DTE minimum number of stop bits in the tx async frame.
    1.3.6.1.4.1.164.3.4.4.4.1.1.5 modmPrtDteRate 0 0 The DTE port rate.
    1.3.6.1.4.1.164.3.4.4.4.1.1.6 modmPrtDteCtsDelay 0 0 CTS/RTS delay, in msec.
    dxx = xx msec.
    notApplicable - for ASMi-31, ASMi-32.
    1.3.6.1.4.1.164.3.4.4.4.1.1.7 modmPrtDteParity 0 0 This attribute indicates the parity mode in async frame.
    1.3.6.1.4.1.164.3.4.4.4.1.1.8 modmPrtDteIfType 0 0 modmPrtDteIftype
    1.3.6.1.4.1.164.3.4.4.4.1.1.9 modmPrtDteRlbEnable 0 0 Enable/Disable Remote Loop-Back on this modem, externally
    initiated.
    1.3.6.1.4.1.164.3.4.4.4.1.1.10 modmPrtDteAlbEnable 0 0 Enable/Disable Analog Loop-Back on this modem, externally
    initiated.
    1.3.6.1.4.1.164.3.4.4.4.1.1.11 modmPrtDteRtsDcdEnable 0 0 Enable/Disable RTS-DCD.
    1.3.6.1.4.1.164.3.4.4.4.1.1.12 modmPrtDteDsrDtrEnable 0 0 Enable/Disable DSR-DTR.
    1.3.6.1.4.1.164.3.4.4.4.1.1.13 modmPrtDteSignaling 0 0 Each bit represents a specific signal state.
    1 - means : signal is ON , Enabled, Yes (exists)
    0 - means : signal is OFF, Disabled…
    1.3.6.1.4.1.164.3.4.4.4.1.1.14 modmPrtDteLoops 0 0 Loops that can be run on the DTE port.
    none - no loop (stop running loop)
    ana - Local Analog Line loop
    rem - Remote Analog Line …
    1.3.6.1.4.1.164.3.4.4.4.1.1.15 modmPrtDteTests 0 0 This is a mask which indicates
    - for Get: which tests are running on the DTE port.
    - for Set: tests the user wishes to start or s…
    1.3.6.1.4.1.164.3.4.4.4.1.1.16 modmPrtDteClearAllTests 0 0 Setting this attribute to on, clears all the running loops
    and tests of the DTE port. Upon completion, the value will
    automatical…
    1.3.6.1.4.1.164.3.4.4.4.1.1.17 modmPrtDteBertResult 0 0 Result of BERT for the selected DTE port.
    Applicable only if BERT is running on the DTE port.
    1.3.6.1.4.1.164.3.4.4.4.1.1.19 modmPrtDteV54DigitalTest 0 0 Enables to start a remote digital loopback upon recognition of a special pattern.
    disable - will not start a digital loopback wh…
    1.3.6.1.4.1.164.3.4.4.4.1.1.20 modmPrtDteV54DigitalTestStatus 0 0 Indicates whether a remote digital test was triggered by a pattern
    by the remote modem or not.
    no - the digital test wasn't trig…
    1.3.6.1.4.1.164.3.4.4.4.1.1.21 modmPrtDteTestTimeOut 0 0 Indicates the timeout for LLB test.
    0=Forever