Defines the contents of each line in the Async RunPro Table.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
Defines the contents of each line in the Async RunPro Table.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications
Module: RAD-MIB (rad-mib.mib)
Type: ENTRY
Access: not-accessible
Syntax: PktSwchAsyncRunProEntry
Automatically extracted from www.mibdepot.com
pktSwchAsyncRunProEntry OBJECT-TYPE SYNTAX PktSwchAsyncRunProEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Async RunPro Table." INDEX { pktSwchAsyncRunProIfIndex } ::= { pktSwchAsyncRunProTable 1 }
pktSwchAsyncRunProEntry OBJECT-TYPE SYNTAX PktSwchAsyncRunProEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Defines the contents of each line in the Async RunPro Table." INDEX { pktSwchAsyncRunProIfIndex } ::= { pktSwchAsyncRunProTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.8.2.6.1.1 | pktSwchAsyncRunProIfIndex | 0 | 0 | An index for the table. |
1.3.6.1.4.1.164.8.2.6.1.2 | pktSwchAsyncRunProChannelNumber | 0 | 0 | The channel to which this entry applies. This value is the same as the pktSwchChannelNumber. |
1.3.6.1.4.1.164.8.2.6.1.3 | pktSwchAsyncRunProRecallChar | 0 | 0 | The character specified by this entry is used to escape from the data transfer mode and enter the PAD command mode. The integer… |
1.3.6.1.4.1.164.8.2.6.1.4 | pktSwchAsyncRunProEcho | 0 | 0 | This determines if an echo of the input characters is retured to the DTE. The options are either 'echo enabled' or 'no echo'. |
1.3.6.1.4.1.164.8.2.6.1.5 | pktSwchAsyncRunProDataForwChar | 0 | 0 | The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) u… |
1.3.6.1.4.1.164.8.2.6.1.6 | pktSwchAsyncRunProIdleTimer | 0 | 0 | Packets will be forwarded when the idle timer expires. The idle time interval is specified as a multiple of 50 milliseconds. T… |
1.3.6.1.4.1.164.8.2.6.1.7 | pktSwchAsyncRunProDevFlowCont | 0 | 0 | This parameter determines whether or not the PAD uses software flow control for the attached device. The options are either (1)… |
1.3.6.1.4.1.164.8.2.6.1.8 | pktSwchAsyncRunProServSig | 0 | 0 | This parameter is used to instruct the PAD whether to transfer PAD service signals and the PAD prompt to the local DTE in standa… |
1.3.6.1.4.1.164.8.2.6.1.9 | pktSwchAsyncRunProBreak | 0 | 0 | The value is a sum of values (powers of two), where each value in the sum represents a PAD operation on receipt of the break sig… |
1.3.6.1.4.1.164.8.2.6.1.10 | pktSwchAsyncRunProDiscOut | 0 | 0 | This parameter instructs the PAD whether to forward the user sequences included in data packets to the local DTE or discard them… |
1.3.6.1.4.1.164.8.2.6.1.11 | pktSwchAsyncRunProCRPPadding | 0 | 0 | This parameter specifies the number of padding characters to be added after a carriage return character is transmitted to the lo… |
1.3.6.1.4.1.164.8.2.6.1.12 | pktSwchAsyncRunProLineFold | 0 | 0 | This parameter specifies the maximum number of characters to be inserted before the format effector. If the value is zero, ther… |
1.3.6.1.4.1.164.8.2.6.1.13 | pktSwchAsyncRunProSpeed | 0 | 0 | This parameter determines the rate of data transmission to and from the DTE. |
1.3.6.1.4.1.164.8.2.6.1.14 | pktSwchAsyncRunProPadFlowCont | 0 | 0 | This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise … |
1.3.6.1.4.1.164.8.2.6.1.15 | pktSwchAsyncRunProLineFeedInsert | 0 | 0 | This parameter indicates when there is a line feed insertion after CR. The options are (1) Insert line feed after transmission … |
1.3.6.1.4.1.164.8.2.6.1.16 | pktSwchAsyncRunProLineFeedPad | 0 | 0 | This parameter specifies the number of padding characters to be added after a line feed. |
1.3.6.1.4.1.164.8.2.6.1.17 | pktSwchAsyncRunProEditing | 0 | 0 | This parameter specifies the editing capabilities available in the data transfer mode. Editing is always possible when the PAD i… |
1.3.6.1.4.1.164.8.2.6.1.18 | pktSwchAsyncRunProCharDel | 0 | 0 | This parameter specifies the character delete, which is one character from IA5. The default selection is 127 (character DEL). |
1.3.6.1.4.1.164.8.2.6.1.19 | pktSwchAsyncRunProLineDel | 0 | 0 | This parameter specifies the line delete, which is one character from IA5. The default selection is 24 (character CAN). |
1.3.6.1.4.1.164.8.2.6.1.20 | pktSwchAsyncRunProLineDisp | 0 | 0 | This entry specifies the line display character, which is one character from IA5. The default selection is 18 (character DC2). |
1.3.6.1.4.1.164.8.2.6.1.21 | pktSwchAsyncRunProEditServSig | 0 | 0 | This entry specifies the editing PAD service signals. The integer values have the following meanings: (0) No edit… |
1.3.6.1.4.1.164.8.2.6.1.22 | pktSwchAsyncRunProEchomask | 0 | 0 | The value is a sum of values (powers of two), where each value in the sum represents a character (or characters) that is (are) i… |
1.3.6.1.4.1.164.8.2.6.1.23 | pktSwchAsyncRunProParTreat | 0 | 0 | This entry controls the generation of parity bits in the data sent to the local DTE and the checking of the parity bit when gene… |
1.3.6.1.4.1.164.8.2.6.1.24 | pktSwchAsyncRunProPageWait | 0 | 0 | This entry specifies the number of line feed characters counted by the PAD before the page wait condition is entered. If the va… |