Reference record for OID 1.3.6.1.4.1.164.8.2.6.1.14



parent
1.3.6.1.4.1.164.8.2.6.1 (pktSwchAsyncRunProEntry)
node code
14
node name
pktSwchAsyncRunProPadFlowCont
dot oid
1.3.6.1.4.1.164.8.2.6.1.14
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radPS(8) pktSwchAsync(2) pktSwchAsyncRunProTable(6) pktSwchAsyncRunProEntry(1) pktSwchAsyncRunProPadFlowCont(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radPS(8) pktSwchAsync(2) pktSwchAsyncRunProTable(6) pktSwchAsyncRunProEntry(1) pktSwchAsyncRunProPadFlowCont(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radPS(8) pktSwchAsync(2) pktSwchAsyncRunProTable(6) pktSwchAsyncRunProEntry(1) pktSwchAsyncRunProPadFlowCont(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radPS(8) pktSwchAsync(2) pktSwchAsyncRunProTable(6) pktSwchAsyncRunProEntry(1) pktSwchAsyncRunProPadFlowCont(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) rad(164) radPS(8) pktSwchAsync(2) pktSwchAsyncRunProTable(6) pktSwchAsyncRunProEntry(1) pktSwchAsyncRunProPadFlowCont(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) rad(164) radPS(8) pktSwchAsync(2) pktSwchAsyncRunProTable(6) pktSwchAsyncRunProEntry(1) pktSwchAsyncRunProPadFlowCont(14)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/rad/radPS/pktSwchAsync/pktSwchAsyncRunProTable/pktSwchAsyncRunProEntry/pktSwchAsyncRunProPadFlowCont
  • /iso/identified-organization/dod/internet/private/enterprises/rad/radPS/pktSwchAsync/pktSwchAsyncRunProTable/pktSwchAsyncRunProEntry/pktSwchAsyncRunProPadFlowCont
  • /iso/org/dod/internet/private/enterprise/rad/radPS/pktSwchAsync/pktSwchAsyncRunProTable/pktSwchAsyncRunProEntry/pktSwchAsyncRunProPadFlowCont
  • /iso/org/dod/internet/private/enterprises/rad/radPS/pktSwchAsync/pktSwchAsyncRunProTable/pktSwchAsyncRunProEntry/pktSwchAsyncRunProPadFlowCont
  • /iso/iso-identified-organization/dod/internet/private/enterprise/rad/radPS/pktSwchAsync/pktSwchAsyncRunProTable/pktSwchAsyncRunProEntry/pktSwchAsyncRunProPadFlowCont
  • /iso/iso-identified-organization/dod/internet/private/enterprises/rad/radPS/pktSwchAsync/pktSwchAsyncRunProTable/pktSwchAsyncRunProEntry/pktSwchAsyncRunProPadFlowCont
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/164/8/2/6/1/14

    Description by mibdepot

    This determines whether or not the terminal can exercise flow control over the PAD.
    The options are either 'device can exercise flow control' or 'device cannot exercise flow
    control.

    Parsed from file Rad0485.MIB.txt
    Company: None
    Module: RAD-MIB

    Description by circitor

    This determines whether or not the terminal can exercise flow control over the PAD.
    The options are either 'device can exercise flow control' or 'device cannot exercise flow
    control.

    Parsed from file RAD-MIB.mib
    Module: RAD-MIB

    Information by oid_info

    Vendor: Rad Data Communications
    Module: RAD-MIB (rad-mib.mib)
    Type: TABULAR
    Access: read-only
    Syntax: INTEGER

    Automatically extracted from www.mibdepot.com

    Information by mibdepot

    pktSwchAsyncRunProPadFlowCont OBJECT-TYPE SYNTAX INTEGER { flowCont(1), noFlowCont(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control." ::= { pktSwchAsyncRunProEntry 14 }

    Information by circitor

    pktSwchAsyncRunProPadFlowCont OBJECT-TYPE SYNTAX INTEGER { flowCont(1), noFlowCont(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "This determines whether or not the terminal can exercise flow control over the PAD. The options are either 'device can exercise flow control' or 'device cannot exercise flow control." ::= { pktSwchAsyncRunProEntry 14 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Brighitte Shalom

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.164)

    Smadar Tauber

    Brothers (23)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.164.8.2.6.1.1 pktSwchAsyncRunProIfIndex 0 0 An index for the table.
    1.3.6.1.4.1.164.8.2.6.1.2 pktSwchAsyncRunProChannelNumber 0 0 The channel to which this entry applies. This value is the same as the pktSwchChannelNumber.
    1.3.6.1.4.1.164.8.2.6.1.3 pktSwchAsyncRunProRecallChar 0 0 The character specified by this entry is used to escape from the data transfer
    mode and enter the PAD command mode. The integer…
    1.3.6.1.4.1.164.8.2.6.1.4 pktSwchAsyncRunProEcho 0 0 This determines if an echo of the input characters is retured to the DTE.
    The options are either 'echo enabled' or 'no echo'.
    1.3.6.1.4.1.164.8.2.6.1.5 pktSwchAsyncRunProDataForwChar 0 0 The value is a sum of values (powers of two), where each value in the sum represents
    a character (or characters) that is (are) u…
    1.3.6.1.4.1.164.8.2.6.1.6 pktSwchAsyncRunProIdleTimer 0 0 Packets will be forwarded when the idle timer expires. The idle time interval is specified
    as a multiple of 50 milliseconds. T…
    1.3.6.1.4.1.164.8.2.6.1.7 pktSwchAsyncRunProDevFlowCont 0 0 This parameter determines whether or not the PAD uses software flow control for the
    attached device. The options are either (1)…
    1.3.6.1.4.1.164.8.2.6.1.8 pktSwchAsyncRunProServSig 0 0 This parameter is used to instruct the PAD whether to transfer PAD service signals and
    the PAD prompt to the local DTE in standa…
    1.3.6.1.4.1.164.8.2.6.1.9 pktSwchAsyncRunProBreak 0 0 The value is a sum of values (powers of two), where each value in the sum represents
    a PAD operation on receipt of the break sig…
    1.3.6.1.4.1.164.8.2.6.1.10 pktSwchAsyncRunProDiscOut 0 0 This parameter instructs the PAD whether to forward the user sequences included in
    data packets to the local DTE or discard them…
    1.3.6.1.4.1.164.8.2.6.1.11 pktSwchAsyncRunProCRPPadding 0 0 This parameter specifies the number of padding characters to be added after a carriage
    return character is transmitted to the lo…
    1.3.6.1.4.1.164.8.2.6.1.12 pktSwchAsyncRunProLineFold 0 0 This parameter specifies the maximum number of characters to be inserted before the
    format effector. If the value is zero, ther…
    1.3.6.1.4.1.164.8.2.6.1.13 pktSwchAsyncRunProSpeed 0 0 This parameter determines the rate of data transmission to and from the DTE.
    1.3.6.1.4.1.164.8.2.6.1.15 pktSwchAsyncRunProLineFeedInsert 0 0 This parameter indicates when there is a line feed insertion after CR. The options are
    (1) Insert line feed after transmission …
    1.3.6.1.4.1.164.8.2.6.1.16 pktSwchAsyncRunProLineFeedPad 0 0 This parameter specifies the number of padding characters to be added after a line
    feed.
    1.3.6.1.4.1.164.8.2.6.1.17 pktSwchAsyncRunProEditing 0 0 This parameter specifies the editing capabilities available in the data transfer mode.
    Editing is always possible when the PAD i…
    1.3.6.1.4.1.164.8.2.6.1.18 pktSwchAsyncRunProCharDel 0 0 This parameter specifies the character delete, which is one character from IA5. The default
    selection is 127 (character DEL).
    1.3.6.1.4.1.164.8.2.6.1.19 pktSwchAsyncRunProLineDel 0 0 This parameter specifies the line delete, which is one character from IA5. The default
    selection is 24 (character CAN).
    1.3.6.1.4.1.164.8.2.6.1.20 pktSwchAsyncRunProLineDisp 0 0 This entry specifies the line display character, which is one character
    from IA5. The default selection is 18 (character DC2).
    1.3.6.1.4.1.164.8.2.6.1.21 pktSwchAsyncRunProEditServSig 0 0 This entry specifies the editing PAD service signals.
    The integer values have the following meanings:
    (0) No edit…
    1.3.6.1.4.1.164.8.2.6.1.22 pktSwchAsyncRunProEchomask 0 0 The value is a sum of values (powers of two), where each value in the sum represents
    a character (or characters) that is (are) i…
    1.3.6.1.4.1.164.8.2.6.1.23 pktSwchAsyncRunProParTreat 0 0 This entry controls the generation of parity bits in the data sent to the local DTE and the
    checking of the parity bit when gene…
    1.3.6.1.4.1.164.8.2.6.1.24 pktSwchAsyncRunProPageWait 0 0 This entry specifies the number of line feed characters counted by the PAD before the
    page wait condition is entered. If the va…