When the number of frames awaiting transmission reaches this figure,
the port transmitter is congested. This field value should be
greater than the Tx pool OK field.
Parsed from file Rad0485.MIB.txt
Company: None
Module: RAD-MIB
When the number of frames awaiting transmission reaches this figure,
the port transmitter is congested. This field value should be
greater than the Tx pool OK field.
Parsed from file RAD-MIB.mib
Module: RAD-MIB
Vendor: Rad Data Communications
Module: RAD-MIB (rad-mib.mib)
Type: TABULAR
Access: read-write
Syntax: Integer32
(
1..500 )
Automatically extracted from www.mibdepot.com
pktSwchFrTxPoolRedLineS OBJECT-TYPE SYNTAX Integer32 (1..500) MAX-ACCESS read-write STATUS current DESCRIPTION "When the number of frames awaiting transmission reaches this figure, the port transmitter is congested. This field value should be greater than the Tx pool OK field." ::= { pktSwchFrSEntry 6 }
pktSwchFrTxPoolRedLineS OBJECT-TYPE SYNTAX Integer32 (1..500) MAX-ACCESS read-write STATUS current DESCRIPTION "When the number of frames awaiting transmission reaches this figure, the port transmitter is congested. This field value should be greater than the Tx pool OK field." ::= { pktSwchFrSEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.164.8.8.2.1.1 | pktSwchFrIfIndexS | 0 | 0 | This is the ifIndex of the frame relay port. |
1.3.6.1.4.1.164.8.8.2.1.2 | pktSwchFrMaintProtS | 0 | 0 | This defines what maintenance protocol is running over this port. 0 - No maintenance protocol. 1 - ANSI PVC maintenance protocol … |
1.3.6.1.4.1.164.8.8.2.1.3 | pktSwchFrMaintModeS | 0 | 0 | This defines the mode of maintenance protocol running over this port. |
1.3.6.1.4.1.164.8.8.2.1.4 | pktSwchFrRxPoolRedLineS | 0 | 0 | When the number of empty receive buffers at the port reaches this figure (of frames),the port receiver is congested. This field… |
1.3.6.1.4.1.164.8.8.2.1.5 | pktSwchFrRxPoolOkS | 0 | 0 | Clear the receive congestion condition when the number of empty receive buffers at the port reaches this figure. This value (of … |
1.3.6.1.4.1.164.8.8.2.1.7 | pktSwchFrTxPoolOkS | 0 | 0 | Clear the transmit congestion condition when the number of frames awaiting transmission at the port reaches this figure. This v… |
1.3.6.1.4.1.164.8.8.2.1.8 | pktSwchFrTxCeilingS | 0 | 0 | The maximum allowable transmit pool for this port. |
1.3.6.1.4.1.164.8.8.2.1.9 | pktSwchFrInternalClockS | 0 | 0 | The baud rate of the internal clock. |
1.3.6.1.4.1.164.8.8.2.1.10 | pktSwchFrNrzModeS | 0 | 0 | The data encoding format. |
1.3.6.1.4.1.164.8.8.2.1.11 | pktSwchFrDlciHeaderModeS | 0 | 0 | Dlci Header length for this FR port. Option 4 means that there will be no management Dlci in the range of 1024 to 8388607. The ma… |
1.3.6.1.4.1.164.8.8.2.1.12 | pktSwchFrDcdLinkFailureS | 0 | 0 | Link Failure Detection by DCD. If Link Failure detection by DCD is on - (3), when the DCD is down, the FR SW will detect it and c… |
1.3.6.1.4.1.164.8.8.2.1.13 | pktSwchFrTxIdlesS | 0 | 0 | This parameter shows whether the PS will Transmit Idles between frames and control the RTS pin. Default: no(2). |
1.3.6.1.4.1.164.8.8.2.1.14 | pktSwchFrOperationModeS | 0 | 0 | When H/W Control is configured, the SCC H/W will detect the change in the DCD or CTS signals and Start or Stop transmission auto… |
1.3.6.1.4.1.164.8.8.2.1.15 | pktSwchFrPhysInterfOptionsS | 0 | 0 | This is the physical interface. Note that the DDS physical interface H/W does not exist in the FPS-8. It is relevant for other PS… |