Reference record for OID 1.3.6.1.4.1.18.3.4.9.3.1.18



parent
1.3.6.1.4.1.18.3.4.9.3.1 (wfDs1E1PortEntry)
node code
18
node name
wfDs1E1PortSendPrmCrAddressBit
dot oid
1.3.6.1.4.1.18.3.4.9.3.1.18
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1PortTable(3) wfDs1E1PortEntry(1) wfDs1E1PortSendPrmCrAddressBit(18)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1PortTable(3) wfDs1E1PortEntry(1) wfDs1E1PortSendPrmCrAddressBit(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1PortTable(3) wfDs1E1PortEntry(1) wfDs1E1PortSendPrmCrAddressBit(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1PortTable(3) wfDs1E1PortEntry(1) wfDs1E1PortSendPrmCrAddressBit(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1PortTable(3) wfDs1E1PortEntry(1) wfDs1E1PortSendPrmCrAddressBit(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) wellfleet(18) wfSwSeries7(3) wfLine(4) wfDs1E1Group(9) wfDs1E1PortTable(3) wfDs1E1PortEntry(1) wfDs1E1PortSendPrmCrAddressBit(18)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1PortTable/wfDs1E1PortEntry/wfDs1E1PortSendPrmCrAddressBit
  • /iso/identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1PortTable/wfDs1E1PortEntry/wfDs1E1PortSendPrmCrAddressBit
  • /iso/org/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1PortTable/wfDs1E1PortEntry/wfDs1E1PortSendPrmCrAddressBit
  • /iso/org/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1PortTable/wfDs1E1PortEntry/wfDs1E1PortSendPrmCrAddressBit
  • /iso/iso-identified-organization/dod/internet/private/enterprise/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1PortTable/wfDs1E1PortEntry/wfDs1E1PortSendPrmCrAddressBit
  • /iso/iso-identified-organization/dod/internet/private/enterprises/wellfleet/wfSwSeries7/wfLine/wfDs1E1Group/wfDs1E1PortTable/wfDs1E1PortEntry/wfDs1E1PortSendPrmCrAddressBit
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/18/3/4/9/3/1/18

    Description by mibdepot

    Specifies the Performance message as originating from either a
    Carrier or Customer Installation (CI). As the performance
    message is sent out the FDL, the PRM Opening Address C/R bit
    is either set (Carrier) or cleared (CI). This feature is only
    supported by the QMCT1.

    Parsed from file ds1e1.mib.txt
    Company: None
    Module: Wellfleet-DS1E1-MIB

    Description by circitor

    Specifies the Performance message as originating from either a
    Carrier or Customer Installation (CI). As the performance
    message is sent out the FDL, the PRM Opening Address C/R bit
    is either set (Carrier) or cleared (CI). This feature is only
    supported by the QMCT1.

    Parsed from file Wellfleet-DS1E1-MIB.mib
    Module: Wellfleet-DS1E1-MIB

    Information by oid_info

    Vendor: Wellfleet
    Module: Wellfleet-DS1E1-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    wfDs1E1PortSendPrmCrAddressBit OBJECT-TYPE SYNTAX INTEGER { prm-ci(1), prm-carrier(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Performance message as originating from either a Carrier or Customer Installation (CI). As the performance message is sent out the FDL, the PRM Opening Address C/R bit is either set (Carrier) or cleared (CI). This feature is only supported by the QMCT1." DEFVAL { prm-ci } ::= { wfDs1E1PortEntry 18 }

    Information by circitor

    wfDs1E1PortSendPrmCrAddressBit OBJECT-TYPE SYNTAX INTEGER { prm-ci(1), prm-carrier(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Performance message as originating from either a Carrier or Customer Installation (CI). As the performance message is sent out the FDL, the PRM Opening Address C/R bit is either set (Carrier) or cleared (CI). This feature is only supported by the QMCT1." DEFVAL { prm-ci } ::= { wfDs1E1PortEntry 18 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.18)

    Caralyn Brown

    Brothers (27)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.18.3.4.9.3.1.1 wfDs1E1PortDelete 0 0 Create/Delete parameter
    1.3.6.1.4.1.18.3.4.9.3.1.2 wfDs1E1PortDisable 0 0 Enable/Disable parameter
    1.3.6.1.4.1.18.3.4.9.3.1.3 wfDs1E1PortState 0 0 Line Driver state variable
    1.3.6.1.4.1.18.3.4.9.3.1.4 wfDs1E1PortLineNumber 0 0 LineNumber for this port. This value is assigned at configuration time
    and uniquely identifies this interface. This LineNumber …
    1.3.6.1.4.1.18.3.4.9.3.1.5 wfDs1E1PortMtu 0 0 MTU parameter. Obsoleted, it is no longer referenced.
    1.3.6.1.4.1.18.3.4.9.3.1.6 wfDs1E1PortSignalLevel 0 0 Specifies T1 transmit power level, in terms of DB. They
    translate into cable length as follows:
    0.0dB -> 0-133 ft
    0.5dB -> 133-2…
    1.3.6.1.4.1.18.3.4.9.3.1.7 wfDs1E1PortSetupAlarmThreshold 0 0 Specifies setup time for performance failure conditions,
    in seconds. When a performance defect is present for greater
    than the ti…
    1.3.6.1.4.1.18.3.4.9.3.1.8 wfDs1E1PortClearAlarmThreshold 0 0 Specifies clear time for performance failure conditions,
    in seconds. When a performance failure condition has been
    cleared for gr…
    1.3.6.1.4.1.18.3.4.9.3.1.9 wfDs1E1PortFdlTargetHdlcAddress 0 0 Selects between the two FDL target address modes. This determines
    whether the near-end FDL will respond to HDLC address AZ or
    BY …
    1.3.6.1.4.1.18.3.4.9.3.1.10 wfDs1E1PortAcceptLoopbackRequest 0 0 The DS1E1 link module is capable of detecting loop up and loop down
    codes received from the far end. This parameter enables and …
    1.3.6.1.4.1.18.3.4.9.3.1.11 wfDs1E1PortLoopbackState 0 0 Indicates the current loopback state of this interface. The interface
    can be in one the following states:
    Payload Loopback
    Line Lo…
    1.3.6.1.4.1.18.3.4.9.3.1.12 wfDs1E1PortBertMode 0 0 An option to generate and analyze specific test patterns
    is provided in BERT mode of operation. Only one port
    can be in BERT mode…
    1.3.6.1.4.1.18.3.4.9.3.1.13 wfDs1E1PortBertTestPattern 0 0 When a port is in BERT mode, it is capable of generating
    a set of known patterns. This paramater selects between those
    patterns
    1.3.6.1.4.1.18.3.4.9.3.1.14 wfDs1E1PortBertSendAlarm 0 0 Specifies a Alarm Indication Signal (AIS) (Blue Alarm) or yellow alarm to
    be transmitted while in BERT mode.
    1.3.6.1.4.1.18.3.4.9.3.1.15 wfDs1E1PortInternationalBit 0 0 Specifies if the International bit should be set in
    the E1 frame
    1.3.6.1.4.1.18.3.4.9.3.1.16 wfDs1E1PortLineApplication 0 0 Specifies the application that the LogicalLines of this Port will provide.
    NONPRI indicates that all of the LogicalLines will ha…
    1.3.6.1.4.1.18.3.4.9.3.1.17 wfDs1E1PortLoggingEnableMask 0 0 Specifies which catagories of extended event log messages are enabled for
    logging. Current bit definitions are:

    bit 31 …
    1.3.6.1.4.1.18.3.4.9.3.1.19 wfDs1E1PortAcceptPrmCrAddressBit 0 0 Accepts only Performance messages originating from either a
    Carrier or Customer Installation (CI), as determined below.
    The PRM O…
    1.3.6.1.4.1.18.3.4.9.3.1.20 wfDs1E1PortLineImpedanceOption 0 0 Supports user selectible Line Impedance option for ASN MCE1
    Net Modules.
    1.3.6.1.4.1.18.3.4.9.3.1.21 wfDs1E1PortFdlLoopInterframeFill 0 0 Enables the Loop Retention Interframe Time Fill for
    the FDL after sending Loop Up Code. Also enables the
    detection of the Loop R…
    1.3.6.1.4.1.18.3.4.9.3.1.22 wfDs1E1PortRelayCtrl 0 0 The Relay on the QMCT1 will always be placed into
    loopback for the following conditions:
    1. Power Up
    2. Reboot
    3. Hardware Reset Bu…
    1.3.6.1.4.1.18.3.4.9.3.1.23 wfDs1E1PortRelayStatus 0 0 This attribute indicates the current state of the Relay
    on the QMCT1. When set to loop (1), the Relay is currently
    looping data …
    1.3.6.1.4.1.18.3.4.9.3.1.24 wfDs1E1PortPrimaryClockSource 0 0 Selects the Primary source of the Tx Clock for the DS1/E1
    interface
    1.3.6.1.4.1.18.3.4.9.3.1.25 wfDs1E1PortSecondaryClockSource 0 0 Selects the Secondary source of the Tx Clock for the DS1/E1
    interface
    1.3.6.1.4.1.18.3.4.9.3.1.26 wfDs1E1PortCurrentClock 0 0 Indicates the clock source currently in use by the DS1
    1.3.6.1.4.1.18.3.4.9.3.1.27 wfDs1E1PortExtClockOperational 0 0 Indicates whether the External clock is operational
    1.3.6.1.4.1.18.3.4.9.3.1.28 wfDs1E1PortTransmitWaveform 0 0 Specifies T1 transmit waveform settings. Legal values are:

    long haul (LBO 0.0dB)
    long haul (LBO 7.5dB)
    long haul (LBO 15.0dB)
    long…