Mean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean.
Parsed from file ONS15501-MIB.mib
Module: ONS15501-MIB
Mean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean.
Mean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean.
Parsed from file ONS15501-MIB.my.txt
Company: None
Module: ONS15501-MIB
Mean value for input optical power.
If the input optical power falls below
the mean value by more than trigger
(see ons15501InputOpticalPowerTrigger) an alarm
is generated. The alarm is cleared when the
input optical power is back within 90% of trigger
from the mean.
ons15501InputOpticalPowerMean OBJECT-TYPE SYNTAX Ons15501TenthdB (-100..0) UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm is generated. The alarm is cleared when the input optical power is back within 90% of trigger from the mean." ::= { ons15501Attr 2 }
ons15501InputOpticalPowerMean OBJECT-TYPE SYNTAX Ons15501TenthdB(-100..0) ACCESS read-write STATUS mandatory DESCRIPTION "Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm is generated. The alarm is cleared when the input optical power is back within 90% of trigger from the mean." ::= { ons15501Attr 2 }
Vendor: Optical Transmission Labs, Inc.
Module: ONS15501-MIB
[Automatically extracted from oidview.com]
ons15501InputOpticalPowerMean OBJECT-TYPE SYNTAX Ons15501TenthdB (-100..0) UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm is generated. The alarm is cleared when the input optical power is back within 90% of trigger from the mean." ::= { ons15501Attr 2 }
ons15501InputOpticalPowerMean OBJECT-TYPE SYNTAX Ons15501TenthdB (-100..0) UNITS "dBm" MAX-ACCESS read-write STATUS current DESCRIPTION "Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputOpticalPowerTrigger) an alarm is generated. The alarm is cleared when the input optical power is back within 90% of trigger from the mean." ::= { ons15501Attr 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1869.11.11.2.2.0 | ons15501InputOpticalPowerMean | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1869.11.11.2.1 | ons15501InputOpticalPower | 1 | 1 | The optical power being fed into the Amplifier. |
1.3.6.1.4.1.1869.11.11.2.3 | ons15501InputOpticalPowerTrigger | 1 | 1 | Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not … |
1.3.6.1.4.1.1869.11.11.2.4 | ons15501OutputOpticalPower | 1 | 1 | The measured value for raw optical power being generated at the output of the Amplifier. |
1.3.6.1.4.1.1869.11.11.2.5 | ons15501OutputSignalPower | 1 | 1 | The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and … |
1.3.6.1.4.1.1869.11.11.2.6 | ons15501OutputSignalPowerMean | 1 | 1 | Mean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (s… |
1.3.6.1.4.1.1869.11.11.2.7 | ons15501OutputSignalPowerTrigger | 1 | 1 | Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not … |
1.3.6.1.4.1.1869.11.11.2.8 | ons15501ConfigOpticalGain | 1 | 1 | The configured value for power gain. |
1.3.6.1.4.1.1869.11.11.2.9 | ons15501OpticalPowerGain | 1 | 1 | The measured value for power gain. This value does not include the amplification noise that is significant for low input signals. |
1.3.6.1.4.1.1869.11.11.2.10 | ons15501GainTrigger | 1 | 1 | The gain deviation allowed from the configured gain before an alarm is asserted. The alarm is not cleared, until measured gain(on… |
1.3.6.1.4.1.1869.11.11.2.11 | ons15501PowerSupply1Level | 1 | 1 | The voltage fed through power supply 1. The value of the attribute is 10 times the the value in volts. |
1.3.6.1.4.1.1869.11.11.2.12 | ons15501PowerSupply2Level | 1 | 1 | The voltage fed through power supply 2. The value of the attribute is 10 times the the value in volts. |
1.3.6.1.4.1.1869.11.11.2.13 | ons15501LaserStatus | 1 | 1 | Gives the status of the laser pumps. |
1.3.6.1.4.1.1869.11.11.2.14 | ons15501DevAmbTemp | 1 | 1 | The ambient temperature for the device. |
1.3.6.1.4.1.1869.11.11.2.15 | ons15501DevAmbTempMean | 1 | 1 | Mean value for temperature. If the temperature falls below (or goes above) the mean value by more than trigger level (see ons15501… |
1.3.6.1.4.1.1869.11.11.2.16 | ons15501DevAmbTempTrigger | 1 | 1 | Please refer to ons15501DevAmbTempMean above. Trigger defines the max deviation allowed from the mean, without an alarm being gen… |
1.3.6.1.4.1.1869.11.11.2.17 | ons15501PowerSupply1Status | 1 | 1 | Gives the status of power supply one. |
1.3.6.1.4.1.1869.11.11.2.18 | ons15501PowerSupply2Status | 1 | 1 | Gives the status of power supply two. |