The optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +
-29 dBm -10 dBm
Input Optical Power
Parsed from file ONS15501-MIB.mib
Module: ONS15501-MIB
The optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +
-29 dBm -10 dBm
Input Optical Power
The optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +
-29 dBm -10 dBm
Input Optical Power
Parsed from file ONS15501-MIB.my.txt
Company: None
Module: ONS15501-MIB
The optical signal power at the output of the Amplifier.
The value of this attribute triggers the alarm, based on
mean value and trigger as defined by
ons15501OutputSignalPowerMean and
ons15501OutputSignalPowerTrigger.
This value is internally calculated using the following
formula.
ons15501OutputSignalPower = ons15501OpticalPowerGain +
ons15501InputOpticalPower
At very low ons15501InputOpticalPower (below -16 dBm),
the ons15501OutputSignalPower has significant difference
from ons15501OutputOpticalPower while at higher input
power (ons15501InputOpticalPower) they are closer.
Following graph captures the difference (for a 17 dBm
EDFA)
(dashes '-'/'_' denote optical output power
while dots '.' denote signal output power)
^
| .-
| .-
| .-
+5 dBm | .-
| .-
Optical | _.-
power / | _ -.
Signal |_ _ - .
power | .
| .
| .
-17 dBm +
-29 dBm -10 dBm
Input Optical Power
ons15501OutputSignalPower OBJECT-TYPE SYNTAX Ons15501TenthdB UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm + -29 dBm -10 dBm Input Optical Power " ::= { ons15501Attr 5 }
ons15501OutputSignalPower OBJECT-TYPE SYNTAX Ons15501TenthdB ACCESS read-only STATUS mandatory DESCRIPTION "The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm + -29 dBm -10 dBm Input Optical Power" ::= { ons15501Attr 5 }
Vendor: Optical Transmission Labs, Inc.
Module: ONS15501-MIB
[Automatically extracted from oidview.com]
ons15501OutputSignalPower OBJECT-TYPE SYNTAX Ons15501TenthdB UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm + -29 dBm -10 dBm Input Optical Power " ::= { ons15501Attr 5 }
ons15501OutputSignalPower OBJECT-TYPE SYNTAX Ons15501TenthdB UNITS "dBm" MAX-ACCESS read-only STATUS current DESCRIPTION "The optical signal power at the output of the Amplifier. The value of this attribute triggers the alarm, based on mean value and trigger as defined by ons15501OutputSignalPowerMean and ons15501OutputSignalPowerTrigger. This value is internally calculated using the following formula. ons15501OutputSignalPower = ons15501OpticalPowerGain + ons15501InputOpticalPower At very low ons15501InputOpticalPower (below -16 dBm), the ons15501OutputSignalPower has significant difference from ons15501OutputOpticalPower while at higher input power (ons15501InputOpticalPower) they are closer. Following graph captures the difference (for a 17 dBm EDFA) (dashes '-'/'_' denote optical output power while dots '.' denote signal output power) ^ | .- | .- | .- +5 dBm | .- | .- Optical | _.- power / | _ -. Signal |_ _ - . power | . | . | . -17 dBm + -29 dBm -10 dBm Input Optical Power " ::= { ons15501Attr 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1869.11.11.2.5.0 | ons15501OutputSignalPower | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.1869.11.11.2.1 | ons15501InputOpticalPower | 1 | 1 | The optical power being fed into the Amplifier. |
1.3.6.1.4.1.1869.11.11.2.2 | ons15501InputOpticalPowerMean | 1 | 1 | Mean value for input optical power. If the input optical power falls below the mean value by more than trigger (see ons15501InputO… |
1.3.6.1.4.1.1869.11.11.2.3 | ons15501InputOpticalPowerTrigger | 1 | 1 | Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not … |
1.3.6.1.4.1.1869.11.11.2.4 | ons15501OutputOpticalPower | 1 | 1 | The measured value for raw optical power being generated at the output of the Amplifier. |
1.3.6.1.4.1.1869.11.11.2.6 | ons15501OutputSignalPowerMean | 1 | 1 | Mean value for output optical power. If the output signal power falls below (or goes above) the mean value by more than trigger (s… |
1.3.6.1.4.1.1869.11.11.2.7 | ons15501OutputSignalPowerTrigger | 1 | 1 | Trigger defines the max deviation allowed from the mean, without an alarm being generated. Once an alarm is generated, it is not … |
1.3.6.1.4.1.1869.11.11.2.8 | ons15501ConfigOpticalGain | 1 | 1 | The configured value for power gain. |
1.3.6.1.4.1.1869.11.11.2.9 | ons15501OpticalPowerGain | 1 | 1 | The measured value for power gain. This value does not include the amplification noise that is significant for low input signals. |
1.3.6.1.4.1.1869.11.11.2.10 | ons15501GainTrigger | 1 | 1 | The gain deviation allowed from the configured gain before an alarm is asserted. The alarm is not cleared, until measured gain(on… |
1.3.6.1.4.1.1869.11.11.2.11 | ons15501PowerSupply1Level | 1 | 1 | The voltage fed through power supply 1. The value of the attribute is 10 times the the value in volts. |
1.3.6.1.4.1.1869.11.11.2.12 | ons15501PowerSupply2Level | 1 | 1 | The voltage fed through power supply 2. The value of the attribute is 10 times the the value in volts. |
1.3.6.1.4.1.1869.11.11.2.13 | ons15501LaserStatus | 1 | 1 | Gives the status of the laser pumps. |
1.3.6.1.4.1.1869.11.11.2.14 | ons15501DevAmbTemp | 1 | 1 | The ambient temperature for the device. |
1.3.6.1.4.1.1869.11.11.2.15 | ons15501DevAmbTempMean | 1 | 1 | Mean value for temperature. If the temperature falls below (or goes above) the mean value by more than trigger level (see ons15501… |
1.3.6.1.4.1.1869.11.11.2.16 | ons15501DevAmbTempTrigger | 1 | 1 | Please refer to ons15501DevAmbTempMean above. Trigger defines the max deviation allowed from the mean, without an alarm being gen… |
1.3.6.1.4.1.1869.11.11.2.17 | ons15501PowerSupply1Status | 1 | 1 | Gives the status of power supply one. |
1.3.6.1.4.1.1869.11.11.2.18 | ons15501PowerSupply2Status | 1 | 1 | Gives the status of power supply two. |