Reference record for OID 1.3.6.1.4.1.223.10.6.17.1


parent
1.3.6.1.4.1.223.10.6.17 (uemSensorTable)
node code
1
node name
uemSensorTableEntry
dot oid
1.3.6.1.4.1.223.10.6.17.1
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17) uemSensorTableEntry(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17) uemSensorTableEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17) uemSensorTableEntry(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17) uemSensorTableEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17) uemSensorTableEntry(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) unisys(223) unisysOpen(10) unisysEnvMonitor(6) uemSensorTable(17) uemSensorTableEntry(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable/uemSensorTableEntry
  • /iso/identified-organization/dod/internet/private/enterprises/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable/uemSensorTableEntry
  • /iso/org/dod/internet/private/enterprise/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable/uemSensorTableEntry
  • /iso/org/dod/internet/private/enterprises/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable/uemSensorTableEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprise/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable/uemSensorTableEntry
  • /iso/iso-identified-organization/dod/internet/private/enterprises/unisys/unisysOpen/unisysEnvMonitor/uemSensorTable/uemSensorTableEntry
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/223/10/6/17/1

    Information by oid_info

    Vendor: Unisys_Corp
    Module: VISINET2-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    uemSensorTableEntry OBJECT-TYPE SYNTAX UemSensorTableEntry ACCESS not-accessible STATUS mandatory INDEX { uemSensorIndex } ::= { uemSensorTable 1 }

    Information by circitor

    uemSensorTableEntry OBJECT-TYPE SYNTAX UemSensorTableEntry ACCESS not-accessible STATUS mandatory INDEX { uemSensorIndex } ::= { uemSensorTable 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.223)

    Brow Lawrence

    Children (16)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.223.10.6.17.1.1 uemSensorIndex 0 0 A unique value for each sensor in the monitored system.
    Note: if there are multiple environmental monitoring cards in a
    system, a…
    1.3.6.1.4.1.223.10.6.17.1.2 uemSensorEnvMonIndex 0 0 A link into the EnvMonitor device table. This identifies which environmental
    device is managing this sensor.
    1.3.6.1.4.1.223.10.6.17.1.3 uemSensorType 0 0 The general classification of this sensor.
    1.3.6.1.4.1.223.10.6.17.1.4 uemSensorDescription 0 0 Text describing this sensor.
    1.3.6.1.4.1.223.10.6.17.1.5 uemSensorStatus 0 0 The current state of the sensor.
    1.3.6.1.4.1.223.10.6.17.1.6 uemSensorValue 0 0 The current numeric value of the sensor. The interpretation of this
    value is related to the type of sensor.
    Fan sensor values are…
    1.3.6.1.4.1.223.10.6.17.1.7 uemSensorNominalValue 0 0 This is the normal value expected to be reported by this sensor in
    a properly operating system.
    1.3.6.1.4.1.223.10.6.17.1.8 uemSensorHighCriticalValue 0 0 When the sensor exceeds this value, a critical trap is sent.
    When appropriate, this test point can be disabled by setting
    it to t…
    1.3.6.1.4.1.223.10.6.17.1.9 uemSensorHighCriticalLabel 0 0 Text describing this test point.
    1.3.6.1.4.1.223.10.6.17.1.10 uemSensorHighWarningValue 0 0 When the sensor value exceeds this value, a warning trap is sent.
    This test point is disabled by setting it to the same value as…
    1.3.6.1.4.1.223.10.6.17.1.11 uemSensorHighWarningLabel 0 0 Text describing this test point.
    1.3.6.1.4.1.223.10.6.17.1.12 uemSensorLowWarningValue 0 0 When the sensor value goes below this value, a warning trap is sent.
    This test point can be disabled by setting it to the same v…
    1.3.6.1.4.1.223.10.6.17.1.13 uemSensorLowWarningLabel 0 0 Text describing this test point.
    1.3.6.1.4.1.223.10.6.17.1.14 uemSensorLowCriticalValue 0 0 When the sensor goes below this value, a critical trap is sent.
    This test point can be disabled by setting it to zero.
    1.3.6.1.4.1.223.10.6.17.1.15 uemSensorLowCriticalLabel 0 0 Text describing this test point.
    1.3.6.1.4.1.223.10.6.17.1.16 uemSensorEnabled 0 0 If this field is FALSE, the sensor is disabled. No traps will be sent
    from a disabled sensor.