When an SNMP message is received by this entity, the
community string in the message is compared with this
string third. If it matches, read-only access is
granted to all items in the MIB except community
strings. (Community strings appear empty when read.)
If it doesn't match, no access is granted, no
response is sent back to the SNMP requester, and
SNMP traps are sent to the SNMP trap receiver(s) if
configured.
Parsed from file xlr30.mib.txt
Company: None
Module: RAPID-CITY-MIB
When an SNMP message is received by this entity, the
community string in the message is compared with this
string third. If it matches, read-only access is
granted to all items in the MIB except community
strings. (Community strings appear empty when read.)
If it doesn't match, no access is granted, no
response is sent back to the SNMP requester, and
SNMP traps are sent to the SNMP trap receiver(s) if
configured.
Parsed from file RAPID-CITY.mib
Module: RAPID-CITY
rcSysCommReadOnly OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string third. If it matches, read-only access is granted to all items in the MIB except community strings. (Community strings appear empty when read.) If it doesn't match, no access is granted, no response is sent back to the SNMP requester, and SNMP traps are sent to the SNMP trap receiver(s) if configured." ::= { rcSystem 6 }
Vendor: Rapid City Communication
Module: RAPID-CITY
[Automatically extracted from oidview.com]
rcSysCommReadOnly OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) ACCESS read-write STATUS mandatory DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string third. If it matches, read-only access is granted to all items in the MIB except community strings. (Community strings appear empty when read.) If it doesn't match, no access is granted, no response is sent back to the SNMP requester, and SNMP traps are sent to the SNMP trap receiver(s) if configured." ::= { rcSystem 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2272.1.1.6.0 | rcSysCommReadOnly | 0 | 0 | None |
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.2272.1.1.1 | rcSysIpAddr | 1 | 1 | This entity's IP address. |
1.3.6.1.4.1.2272.1.1.2 | rcSysNetMask | 1 | 1 | This entity's subnet mask. |
1.3.6.1.4.1.2272.1.1.3 | rcSysBroadcast | 1 | 1 | This entity's broadcast address. |
1.3.6.1.4.1.2272.1.1.4 | rcSysCommReadWriteAll | 1 | 1 | When an SNMP message is received by this entity, the community string in the message is compared with this string first. If it m… |
1.3.6.1.4.1.2272.1.1.5 | rcSysCommReadWrite | 1 | 1 | When an SNMP message is received by this entity, the community string in the message is compared with this string second. If it … |
1.3.6.1.4.1.2272.1.1.7 | rcSysVersion | 1 | 1 | Software version running on device |
1.3.6.1.4.1.2272.1.1.8 | rcSysAction | 1 | 1 | Initiate a system action. |
1.3.6.1.4.1.2272.1.1.9 | rcSysResult | 1 | 1 | Result from the last system action. |
1.3.6.1.4.1.2272.1.1.10 | rcSysLastChange | 1 | 1 | Last management initiated configuration change since sysUpTime. |
1.3.6.1.4.1.2272.1.1.11 | rcSysLastVlanChange | 1 | 1 | Last management initiated VLAN configuration change since sysUpTime. |
1.3.6.1.4.1.2272.1.1.12 | rcSysLastStatisticsReset | 1 | 1 | Last management initiated statistics reset since sysUpTime. |
1.3.6.1.4.1.2272.1.1.13 | rcSysBufferUtil | 1 | 1 | Buffer utilization as a percentage of the total amount of buffer space in the system. A high value indicates congestion. |
1.3.6.1.4.1.2272.1.1.14 | rcSysBufferUtilPeak | 1 | 1 | The largest buffer utilization since sysUpTime |
1.3.6.1.4.1.2272.1.1.15 | rcSysBufferUtilPeakTime | 1 | 1 | Timestamp for rcSysPeakBandwidth |
1.3.6.1.4.1.2272.1.1.16 | rcSysNVRamSize | 1 | 1 | Total Non-volatile RAM in Kbytes |
1.3.6.1.4.1.2272.1.1.17 | rcSysNVRamUsed | 1 | 1 | Non-volatile RAM in use in Kbytes |
1.3.6.1.4.1.2272.1.1.18 | rcSysLastSaveToNVRam | 1 | 1 | SysUpTime of the last time when NVRAM was written to. This could be a save of the system configuration or via a file transfer of… |
1.3.6.1.4.1.2272.1.1.19 | rcSysLastSaveToStandbyNVRam | 1 | 1 | SysUpTime of the last time when the standby NVRAM (on the back-up CPU board) was written to. |
1.3.6.1.4.1.2272.1.1.20 | rcSysCpuUtil | 1 | 1 | Percentage of CPU utilization |
1.3.6.1.4.1.2272.1.1.21 | rcSysSwitchFabricUtil | 1 | 1 | Percentage of Switching Fabric utilization |
1.3.6.1.4.1.2272.1.1.22 | rcSysRmonMemSize | 1 | 1 | Amount of RAM in bytes to allocate for RMON to use when rcSysRmonEnable is TRUE. |
1.3.6.1.4.1.2272.1.1.23 | rcSysRmonEnable | 1 | 1 | Control whether the RMON feature should be enabled. To enable the RMON feature, set this variable to true. The RMON agent in the … |
1.3.6.1.4.1.2272.1.1.24 | rcSysRmonSaveConfig | 1 | 1 | Control whether RMON configuration information should be saved to NVRAM so RMON settings can be automatically reinstalled after a… |
1.3.6.1.4.1.2272.1.1.25 | rcSysRmonTrapOption | 1 | 1 | Used to indicate whether RMON traps should be sent to only the owner of the RMON alarm (i.e., the manager that created the alarm … |
1.3.6.1.4.1.2272.1.1.26 | rcSysSupportRouting | 1 | 1 | Used to indicate whether routing is supported in this product. |
1.3.6.1.4.1.2272.1.1.27 | rcSysSupportWebServer | 1 | 1 | Used to indicate whether WebServer is supported in this product. |
1.3.6.1.4.1.2272.1.1.28 | rcSysLastIpAddrChange | 1 | 1 | Last management initiated IP address change since sysUpTime. Any addition or deletion of an IP address to a single routable port… |
1.3.6.1.4.1.2272.1.1.29 | rcSysCommReadWriteLayer3 | 1 | 1 | When an SNMP message is received by this entity, the community string in the message is compared with this string third. If it m… |
1.3.6.1.4.1.2272.1.1.30 | rcSysCommReadWriteLayer2 | 1 | 1 | When an SNMP message is received by this entity, the community string in the message is compared with this string fourth. If it … |
1.3.6.1.4.1.2272.1.1.31 | rcSysAccessPolicyEnable | 1 | 1 | Used to configure the system access policy feature. if 'true', the rcSysAccessPolicyTable is examined to determine which packets … |
1.3.6.1.4.1.2272.1.1.32 | rcSysDefaultRuntimeConfigFileName | 1 | 1 | default config. |
1.3.6.1.4.1.2272.1.1.33 | rcSysDefaultBootConfigFileName | 1 | 1 | default boot config. |
1.3.6.1.4.1.2272.1.1.34 | rcSysConfigFileName | 1 | 1 | File name used in conjunction with rcSysAction. If rcSysAction is set to 'saveRuntimeConfig' or 'saveRuntimeConfigToSlave' then t… |
1.3.6.1.4.1.2272.1.1.35 | rcSysLastRunTimeConfigSave | 1 | 1 | SysUpTime of the last time when the run time configuration was written to. |
1.3.6.1.4.1.2272.1.1.36 | rcSysLastRunTimeConfigSaveToSlave | 1 | 1 | SysUpTime of the last time when the run time configuration was written to slave NVRAM. |
1.3.6.1.4.1.2272.1.1.37 | rcSysLastBootConfigSave | 1 | 1 | SysUpTime of the last time when the boot configuration was written to. |
1.3.6.1.4.1.2272.1.1.38 | rcSysLastBootConfigSaveOnSlave | 1 | 1 | SysUpTime of the last time when the boot configuration was written on the slave NVRAM. |
1.3.6.1.4.1.2272.1.1.39 | rcSysRmonUtilizationMethod | 1 | 1 | Used to control whether RMON should use a half-duplex or full-duplex formula to calculate port utilization. When set to 'halfDupl… |
1.3.6.1.4.1.2272.1.1.40 | rcSysCommReadWriteLayer1 | 1 | 1 | read-write L1 access |
1.3.6.1.4.1.2272.1.1.41 | rcSysOtherBufferUtil | 1 | 1 | bw currently consumed |
1.3.6.1.4.1.2272.1.1.42 | rcSysOtherBufferUtilPeak | 1 | 1 | peak bw since reset |
1.3.6.1.4.1.2272.1.1.43 | rcSysOtherBufferUtilPeakTime | 1 | 1 | timestamp for rcSysPeakBw |
1.3.6.1.4.1.2272.1.1.44 | rcSysOtherCpuUtil | 1 | 1 | % cpu utilization |
1.3.6.1.4.1.2272.1.1.45 | rcSysOtherSwitchFabricUtil | 1 | 1 | % switch fabric util |
1.3.6.1.4.1.2272.1.1.46 | rcSysDramSize | 1 | 1 | Dram size in mega-bytes |
1.3.6.1.4.1.2272.1.1.47 | rcSysDramUsed | 1 | 1 | Dram used in percentage |
1.3.6.1.4.1.2272.1.1.48 | rcSysDramFree | 1 | 1 | Dram free size in kilo-bytes |
1.3.6.1.4.1.2272.1.1.49 | rcSysDramMaxBlockFree | 1 | 1 | Dram max block free size in kilo-bytes |
1.3.6.1.4.1.2272.1.1.51 | rcSysVirtualIpAddr | 1 | 1 | Virtual IP is an IP address that owned and advertised only by the master CPU. So whichever CPU is master registers this IP addres… |
1.3.6.1.4.1.2272.1.1.52 | rcSysVirtualNetMask | 1 | 1 | Net mask of the management virtual Ip address |
1.3.6.1.4.1.2272.1.1.53 | rcSysReadWriteLevel | 1 | 1 | The status of the read/write level |
1.3.6.1.4.1.2272.1.1.55 | rcSysMTUSize | 1 | 1 | This is the maximum transmission size of frames that all the ports on the chassis support. |
1.3.6.1.4.1.2272.1.1.56 | rcSysClockSyncTime | 1 | 1 | Time interval at which RTC and system clocks are synchronized. |
... |