Differential cable pair length in meters.
Skew measurement can only be performed when cable
gigabit link is up regardless of traffic activity.
A value of -1 means an error occured when trying
to get the length.
Parsed from file RC-DIAG-MIB.mib.txt
Company: avaya
Module: RC-DIAG-MIB
rcDiagVctPair4Skew OBJECT-TYPE SYNTAX Integer32 (-1..15) MAX-ACCESS read-only STATUS current DESCRIPTION "Differential cable pair length in meters. Skew measurement can only be performed when cable gigabit link is up regardless of traffic activity. A value of -1 means an error occured when trying to get the length." ::= { rcDiagVctEntry 28 }
Vendor: Avaya
Module: RC-DIAG-MIB (RC-DIAG-MIB.mib)
Type: TABULAR
Access: read-only
Syntax: Integer32
(
-1..15 )
Automatically extracted from www.mibdepot.com
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.2272.1.23.4.1.1 | rcDiagVctIfIndex | 0 | 0 | Port IfIndex. |
1.3.6.1.4.1.2272.1.23.4.1.2 | rcDiagVctNormalCableLength | 0 | 0 | Cable length, this indicates a range in which the actual length falls. |
1.3.6.1.4.1.2272.1.23.4.1.3 | rcDiagVctPhyType | 0 | 0 | Phy type, 100MHz throught 1 GHz, or broadcom phy. |
1.3.6.1.4.1.2272.1.23.4.1.4 | rcDiagVctCableStatus | 0 | 0 | Status of the cable as a whole. The status of a cable is in a sense, a summation of the status of its pairs. If all the pairs a… |
1.3.6.1.4.1.2272.1.23.4.1.5 | rcDiagVctPair1Status | 0 | 0 | The status of a single pair in the cable |
1.3.6.1.4.1.2272.1.23.4.1.6 | rcDiagVctPair1ErrLength | 0 | 0 | Error Pair Length, in meters, measured by Time Domain Reflectometry. |
1.3.6.1.4.1.2272.1.23.4.1.7 | rcDiagVctPair2Status | 0 | 0 | The status of a single pair in the cable |
1.3.6.1.4.1.2272.1.23.4.1.8 | rcDiagVctPair2ErrLength | 0 | 0 | Error Pair Length, in meters, measured by Time Domain Reflectometry. |
1.3.6.1.4.1.2272.1.23.4.1.9 | rcDiagVctPair3Status | 0 | 0 | The status of a single pair in the cable |
1.3.6.1.4.1.2272.1.23.4.1.10 | rcDiagVctPair3ErrLength | 0 | 0 | Error Pair Length, in meters, measured by Time Domain Reflectometry. |
1.3.6.1.4.1.2272.1.23.4.1.11 | rcDiagVctPair4Status | 0 | 0 | The status of a single pair in the cable |
1.3.6.1.4.1.2272.1.23.4.1.12 | rcDiagVctPair4ErrLength | 0 | 0 | Error Pair Length, in meters, measured by Time Domain Reflectometry. |
1.3.6.1.4.1.2272.1.23.4.1.13 | rcDiagVctStartTest | 0 | 0 | Start VCT test, Set this object to TRUE to perform a VCT test on the current port. A get on this object produces an undefines val… |
1.3.6.1.4.1.2272.1.23.4.1.14 | rcDiagVctTestDone | 0 | 0 | When a VCT test is started setting rcDiagVctStartTest, this object is immediately set to FALSE by the switch software. It remain … |
1.3.6.1.4.1.2272.1.23.4.1.15 | rcDiagVctCableCategory | 0 | 0 | Cable type: CAT3 or CAT5. |
1.3.6.1.4.1.2272.1.23.4.1.16 | rcDiagVctCableLength | 0 | 0 | Length of cable in meters based on average electrical length of 4 pairs. Measurement can be done when traffic is live or not. |
1.3.6.1.4.1.2272.1.23.4.1.17 | rcDiagVctPair1Polarity | 0 | 0 | The polarity of a single pair in the cable. |
1.3.6.1.4.1.2272.1.23.4.1.18 | rcDiagVctPair1Swap | 0 | 0 | The pair swap in the cable. |
1.3.6.1.4.1.2272.1.23.4.1.19 | rcDiagVctPair1Skew | 0 | 0 | Differential cable pair length in meters. Skew measurement can only be performed when cable gigabit link is up regardless of traf… |
1.3.6.1.4.1.2272.1.23.4.1.20 | rcDiagVctPair2Polarity | 0 | 0 | The polarity of a single pair in the cable. |
1.3.6.1.4.1.2272.1.23.4.1.21 | rcDiagVctPair2Swap | 0 | 0 | The pair swap in the cable. |
1.3.6.1.4.1.2272.1.23.4.1.22 | rcDiagVctPair2Skew | 0 | 0 | Differential cable pair length in meters. Skew measurement can only be performed when cable gigabit link is up regardless of traf… |
1.3.6.1.4.1.2272.1.23.4.1.23 | rcDiagVctPair3Polarity | 0 | 0 | The polarity of a single pair in the cable. |
1.3.6.1.4.1.2272.1.23.4.1.24 | rcDiagVctPair3Swap | 0 | 0 | The pair swap in the cable. |
1.3.6.1.4.1.2272.1.23.4.1.25 | rcDiagVctPair3Skew | 0 | 0 | Differential cable pair length in meters. Skew measurement can only be performed when cable gigabit link is up regardless of traf… |
1.3.6.1.4.1.2272.1.23.4.1.26 | rcDiagVctPair4Polarity | 0 | 0 | The polarity of a single pair in the cable. |