Seek Errors (High).
The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
total number of times that the physical disk drive detected a
seek error during the reference hours (phyDrvRefHours).
The actual number of seek errors equals the phyDrvHSeekErrs times
2^32 plus the phyDrvWriteSeekErrs.
Over time, a disk drive usually produces these errors. If you
notice a rapid increase in the value shown for Seek Errors,
this physical drive may be failing.
The value increases every time the physical drive produces
another error. Only an unusually rapid increase in these errors
indicates a problem. If you suspect that a problem exists,
schedule server down time to run Compaq Diagnostics.
Parsed from file CPQIDA2.MIB.txt
Company: None
Module: CPQIDA-MIB
Seek Errors (High).
The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the
total number of times that the physical disk drive detected a
seek error during the reference hours (phyDrvRefHours).
The actual number of seek errors equals the phyDrvHSeekErrs times
2^32 plus the phyDrvWriteSeekErrs.
Over time, a disk drive usually produces these errors. If you
notice a rapid increase in the value shown for Seek Errors,
this physical drive may be failing.
The value increases every time the physical drive produces
another error. Only an unusually rapid increase in these errors
indicates a problem. If you suspect that a problem exists,
schedule server down time to run diagnostics.
Parsed from file CPQIDA-MIB.mib
Module: CPQIDA-MIB
cpqDaPhyDrvHSeekErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Seek Errors (High). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). The actual number of seek errors equals the phyDrvHSeekErrs times 2^32 plus the phyDrvWriteSeekErrs. Over time, a disk drive usually produces these errors. If you notice a rapid increase in the value shown for Seek Errors, this physical drive may be failing. The value increases every time the physical drive produces another error. Only an unusually rapid increase in these errors indicates a problem. If you suspect that a problem exists, schedule server down time to run Compaq Diagnostics." ::= { cpqDaPhyDrvEntry 20 }
Vendor: Compaq
Module: CPQIDA-MIB
[Automatically extracted from oidview.com]
cpqDaPhyDrvHSeekErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Seek Errors (High). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk drive detected a seek error during the reference hours (phyDrvRefHours). The actual number of seek errors equals the phyDrvHSeekErrs times 2^32 plus the phyDrvWriteSeekErrs. Over time, a disk drive usually produces these errors. If you notice a rapid increase in the value shown for Seek Errors, this physical drive may be failing. The value increases every time the physical drive produces another error. Only an unusually rapid increase in these errors indicates a problem. If you suspect that a problem exists, schedule server down time to run diagnostics." ::= { cpqDaPhyDrvEntry 20 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.3.2.5.1.1.1 | cpqDaPhyDrvCntlrIndex | 0 | 0 | Drive Array Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. T… |
1.3.6.1.4.1.232.3.2.5.1.1.2 | cpqDaPhyDrvIndex | 0 | 0 | Drive Array Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cp… |
1.3.6.1.4.1.232.3.2.5.1.1.3 | cpqDaPhyDrvModel | 0 | 0 | Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the … |
1.3.6.1.4.1.232.3.2.5.1.1.4 | cpqDaPhyDrvFWRev | 0 | 0 | Physical Drive Firmware Revision. This shows the physical drive revision number. If the firmware revision is not present, you hav… |
1.3.6.1.4.1.232.3.2.5.1.1.5 | cpqDaPhyDrvBay | 0 | 0 | Physical Drive Bay Location. This value matches the bay location where the physical drive has been installed. Each bay is labele… |
1.3.6.1.4.1.232.3.2.5.1.1.6 | cpqDaPhyDrvStatus | 0 | 0 | Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status:… |
1.3.6.1.4.1.232.3.2.5.1.1.7 | cpqDaPhyDrvFactReallocs | 0 | 0 | This shows the number of spare sectors available for remapping at the time the physical drive was shipped. The physical drive wil… |
1.3.6.1.4.1.232.3.2.5.1.1.8 | cpqDaPhyDrvUsedReallocs | 0 | 0 | Physical Drive Used Reallocated Sectors. This shows the number of sectors of the reallocation area that have been used by the phy… |
1.3.6.1.4.1.232.3.2.5.1.1.9 | cpqDaPhyDrvRefHours | 0 | 0 | Reference Time in hours. This shows the total number of hours that a physical drive has been spinning since the drive was stamped… |
1.3.6.1.4.1.232.3.2.5.1.1.10 | cpqDaPhyDrvHReads | 0 | 0 | Sectors Read (high). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk … |
1.3.6.1.4.1.232.3.2.5.1.1.11 | cpqDaPhyDrvReads | 0 | 0 | Sectors Read (low). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk d… |
1.3.6.1.4.1.232.3.2.5.1.1.12 | cpqDaPhyDrvHWrites | 0 | 0 | Sectors Written (high). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical… |
1.3.6.1.4.1.232.3.2.5.1.1.13 | cpqDaPhyDrvWrites | 0 | 0 | Sectors Written (low). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical d… |
1.3.6.1.4.1.232.3.2.5.1.1.14 | cpqDaPhyDrvHSeeks | 0 | 0 | Total Seeks (high). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the phys… |
1.3.6.1.4.1.232.3.2.5.1.1.15 | cpqDaPhyDrvSeeks | 0 | 0 | Total Seeks (low). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physi… |
1.3.6.1.4.1.232.3.2.5.1.1.16 | cpqDaPhyDrvHardReadErrs | 0 | 0 | Hard Read Errors. This shows the number of read errors that have occurred on a drive that could not be recovered by a physical dr… |
1.3.6.1.4.1.232.3.2.5.1.1.17 | cpqDaPhyDrvRecvReadErrs | 0 | 0 | Recovered Read Errors. This shows the number of read errors corrected through physical drive retries during the reference time (p… |
1.3.6.1.4.1.232.3.2.5.1.1.18 | cpqDaPhyDrvHardWriteErrs | 0 | 0 | Hard Write Errors. This shows the number of write errors that could not be recovered by a physical drive during the reference tim… |
1.3.6.1.4.1.232.3.2.5.1.1.19 | cpqDaPhyDrvRecvWriteErrs | 0 | 0 | Recovered Write Errors. This shows the number of write errors corrected through physical drive retries or recovered by a physical… |
1.3.6.1.4.1.232.3.2.5.1.1.21 | cpqDaPhyDrvSeekErrs | 0 | 0 | Seek Errors (low). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk dri… |
1.3.6.1.4.1.232.3.2.5.1.1.22 | cpqDaPhyDrvSpinupTime | 0 | 0 | Spin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to … |
1.3.6.1.4.1.232.3.2.5.1.1.23 | cpqDaPhyDrvFunctTest1 | 0 | 0 | Functional Test 1. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.3.2.5.1.1.24 | cpqDaPhyDrvFunctTest2 | 0 | 0 | Functional Test 2. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.3.2.5.1.1.25 | cpqDaPhyDrvFunctTest3 | 0 | 0 | Functional Test 3. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.3.2.5.1.1.26 | cpqDaPhyDrvDrqTimeouts | 0 | 0 | DRQ Timeouts. The number of times that a physical drive continued to request data, but did not get a command completion during t… |
1.3.6.1.4.1.232.3.2.5.1.1.27 | cpqDaPhyDrvOtherTimeouts | 0 | 0 | Other Timeouts. The number of times that a physical drive did not respond with an interrupt within a controller-defined period of… |
1.3.6.1.4.1.232.3.2.5.1.1.28 | cpqDaPhyDrvSpinupRetries | 0 | 0 | Spin up Retries. The number of times that a physical drive had to retry to spin up before successfully achieving operating speed … |
1.3.6.1.4.1.232.3.2.5.1.1.29 | cpqDaPhyDrvBadRecvReads | 0 | 0 | Recovery Failed (Bad) Read Error. The number of times a read error occurred while performing Automatic Data Recovery from this ph… |
1.3.6.1.4.1.232.3.2.5.1.1.30 | cpqDaPhyDrvBadRecvWrites | 0 | 0 | Recovery Failed (Bad) Write Error. The number of times a write error occurred while performing Automatic Data Recovery from anoth… |
1.3.6.1.4.1.232.3.2.5.1.1.31 | cpqDaPhyDrvFormatErrs | 0 | 0 | Format Error. The number of times a format operation failed when the controller attempted to remap a bad sector during the refere… |
1.3.6.1.4.1.232.3.2.5.1.1.32 | cpqDaPhyDrvPostErrs | 0 | 0 | Power On Self Test (Post) Error. The number of times that a physical drive failed its self test during the reference time (phyDrv… |
1.3.6.1.4.1.232.3.2.5.1.1.33 | cpqDaPhyDrvNotReadyErrs | 0 | 0 | Drive Not Ready Errors. The number of times the physical drive failed after the spin up command was issued during the reference t… |
1.3.6.1.4.1.232.3.2.5.1.1.34 | cpqDaPhyDrvReallocAborts | 0 | 0 | Physical Drive Reallocation Aborts. The number of times the physical drive has failed due to an error that occurred when the cont… |
1.3.6.1.4.1.232.3.2.5.1.1.35 | cpqDaPhyDrvThreshPassed | 0 | 0 | Physical Drive Factory Threshold Passed (Exceeded). When the drive is shipped, certain thresholds have been set to monitor perfor… |
1.3.6.1.4.1.232.3.2.5.1.1.36 | cpqDaPhyDrvHasMonInfo | 0 | 0 | Physical Drive Has Monitor Information. All of the physical disk table fields except for the physical disk status (phyDrvStatus) … |
1.3.6.1.4.1.232.3.2.5.1.1.37 | cpqDaPhyDrvCondition | 0 | 0 | The condition of the device. This value represents the overall condition of this physical drive. |
1.3.6.1.4.1.232.3.2.5.1.1.38 | cpqDaPhyDrvHotPlugs | 0 | 0 | Physical Drive Hot Plug Count. This value indicates the number of times this physical drive was hot-plugged (removed) from a ProL… |
1.3.6.1.4.1.232.3.2.5.1.1.39 | cpqDaPhyDrvMediaErrs | 0 | 0 | Physical Drive Media Failure Count. This value indicates the number of times this physical drive was failed due to unrecoverable … |
1.3.6.1.4.1.232.3.2.5.1.1.40 | cpqDaPhyDrvHardwareErrs | 0 | 0 | Physical Drive Hardware Error Count. This value indicates the number of times this physical drive returned a bad hardware status.… |
1.3.6.1.4.1.232.3.2.5.1.1.41 | cpqDaPhyDrvAbortedCmds | 0 | 0 | Physical Drive Aborted Command Failures. This value indicates the number of times this physical drive was failed due to aborted c… |
1.3.6.1.4.1.232.3.2.5.1.1.42 | cpqDaPhyDrvSpinUpErrs | 0 | 0 | Physical Drive Spin-Up Failure Count. This value indicates the number of times this physical drive was failed due to a failure of… |
1.3.6.1.4.1.232.3.2.5.1.1.43 | cpqDaPhyDrvBadTargetErrs | 0 | 0 | Physical Drive Bad Target Count. This value indicates the number of times this physical drive performed some action that did not … |
1.3.6.1.4.1.232.3.2.5.1.1.44 | cpqDaPhyDrvLocation | 0 | 0 | Drive Physical Location. This is the physical location of where the drive is located. The following values are defined: other(1) Th… |
1.3.6.1.4.1.232.3.2.5.1.1.45 | cpqDaPhyDrvSize | 0 | 0 | Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,5… |
1.3.6.1.4.1.232.3.2.5.1.1.46 | cpqDaPhyDrvBusFaults | 0 | 0 | Physical Drive Bus Fault Count. This value indicates the number of times that a bus fault was detected for the drive by the contr… |
1.3.6.1.4.1.232.3.2.5.1.1.47 | cpqDaPhyDrvIrqDeglitches | 0 | 0 | Physical Drive IRQ Deglitch Count. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers. |
1.3.6.1.4.1.232.3.2.5.1.1.48 | cpqDaPhyDrvHotPlug | 0 | 0 | Physical Drive Hot Plug Support Status. The following values are defined: other(1) The Insight Agent is unable to determine if thi… |
1.3.6.1.4.1.232.3.2.5.1.1.49 | cpqDaPhyDrvPlacement | 0 | 0 | Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or e… |
1.3.6.1.4.1.232.3.2.5.1.1.50 | cpqDaPhyDrvBusNumber | 0 | 0 | Physical Drive SCSI Bus Number. The bus number indicates to which SCSI bus this physical drive is attached. The first instance i… |
1.3.6.1.4.1.232.3.2.5.1.1.51 | cpqDaPhyDrvSerialNum | 0 | 0 | Physical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial numbe… |
1.3.6.1.4.1.232.3.2.5.1.1.52 | cpqDaPhyDrvPreFailMonitoring | 0 | 0 | Drive Array Physical Drive Predictive Failure Monitoring. The following values are defined: other(1) The agent is unable to determ… |
1.3.6.1.4.1.232.3.2.5.1.1.53 | cpqDaPhyDrvCurrentWidth | 0 | 0 | Drive Array Physical Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current … |
1.3.6.1.4.1.232.3.2.5.1.1.54 | cpqDaPhyDrvCurrentSpeed | 0 | 0 | Drive Array Physical Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determin… |
1.3.6.1.4.1.232.3.2.5.1.1.55 | cpqDaPhyDrvFailureCode | 0 | 0 | Drive Array Physical Drive Failure Code. This value is the drive failure reason code returned by the array firmware. It is valid… |
1.3.6.1.4.1.232.3.2.5.1.1.56 | cpqDaPhyDrvBlinkTime | 0 | 0 | Physical Drive Blink Time Count. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs wil… |
1.3.6.1.4.1.232.3.2.5.1.1.57 | cpqDaPhyDrvSmartStatus | 0 | 0 | Physical Drive S.M.A.R.T Status. The following values are defined: other(1) The agent is unable to determine if the status of S.M.… |
1.3.6.1.4.1.232.3.2.5.1.1.58 | cpqDaPhyDrvConfigurationStatus | 0 | 0 | Physical Drive Configuration Status. The following values are defined: other(1) The agent is unable to determine the configuration… |
1.3.6.1.4.1.232.3.2.5.1.1.59 | cpqDaPhyDrvRotationalSpeed | 0 | 0 | Drive Array Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotat… |
1.3.6.1.4.1.232.3.2.5.1.1.60 | cpqDaPhyDrvType | 0 | 0 | Physical Drive Type. The following values are defined: other(1) The agent is unable to determine the type for this drive. parallelS… |
1.3.6.1.4.1.232.3.2.5.1.1.61 | cpqDaPhyDrvSataVersion | 0 | 0 | Physical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this… |
1.3.6.1.4.1.232.3.2.5.1.1.62 | cpqDaPhyDrvHostConnector | 0 | 0 | Physical Drive Host Connector. This is the host connector to which the drive is ultimately attached. If the host connector canno… |
1.3.6.1.4.1.232.3.2.5.1.1.63 | cpqDaPhyDrvBoxOnConnector | 0 | 0 | Physical Drive Box on Connector. The box on connector indicates to which box instance this physical drive belongs. The instances… |
1.3.6.1.4.1.232.3.2.5.1.1.64 | cpqDaPhyDrvLocationString | 0 | 0 | Physical Drive Location String. This string describes the location of the drive in relation to the controller. If the location s… |
1.3.6.1.4.1.232.3.2.5.1.1.65 | cpqDaPhyDrvNegotiatedLinkRate | 0 | 0 | Drive Array Physical Drive Negotiated Link Rate. The following values are defined: other(1) The agent is unable to determine the n… |
1.3.6.1.4.1.232.3.2.5.1.1.66 | cpqDaPhyDrvNcqSupport | 0 | 0 | Drive Array Physical Drive Native Command Queueing. The following values are defined: other(1) The agent is unable to determine th… |
1.3.6.1.4.1.232.3.2.5.1.1.67 | cpqDaPhyDrvPhyCount | 0 | 0 | Drive Array Physical Drive PHY Count. This value indicates how many PHYs exist on SAS/SATA disk. For parallel SCSI disks, this v… |
1.3.6.1.4.1.232.3.2.5.1.1.68 | cpqDaPhyDrvMultipathAccess | 0 | 0 | Drive Array Physical Drive Multi-path Access Status. This indicates if this physical drive has been configured to have and curren… |
1.3.6.1.4.1.232.3.2.5.1.1.69 | cpqDaPhyDrvMediaType | 0 | 0 | Physical Drive Media Type. The following values are defined: other(1) The instrument agent is unable to determine the physical dri… |