Spin up Retries.
The number of times that a physical drive had to retry to spin up
before successfully achieving operating speed during the reference
time (phyDrvRefTime). This value represents the spin-up retries
that occurred since the last time you turned on the monitored
system.
If you suspect a problem, schedule server down time to run Compaq
Diagnostics and select the Drive Monitoring Diagnostics option to
verify that a problem exists.
Parsed from file CPQIDA2.MIB.txt
Company: None
Module: CPQIDA-MIB
Spin up Retries.
The number of times that a physical drive had to retry to spin up
before successfully achieving operating speed during the reference
time (phyDrvRefTime). This value represents the spin-up retries
that occurred since the last time you turned on the monitored
system.
If you suspect a problem, schedule server down time to run
diagnostics verify that a problem exists.
Parsed from file CPQIDA-MIB.mib
Module: CPQIDA-MIB
cpqDaPhyDrvSpinupRetries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Spin up Retries. The number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This value represents the spin-up retries that occurred since the last time you turned on the monitored system. If you suspect a problem, schedule server down time to run Compaq Diagnostics and select the Drive Monitoring Diagnostics option to verify that a problem exists." ::= { cpqDaPhyDrvEntry 28 }
Vendor: Compaq
Module: CPQIDA-MIB
[Automatically extracted from oidview.com]
cpqDaPhyDrvSpinupRetries OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Spin up Retries. The number of times that a physical drive had to retry to spin up before successfully achieving operating speed during the reference time (phyDrvRefTime). This value represents the spin-up retries that occurred since the last time you turned on the monitored system. If you suspect a problem, schedule server down time to run diagnostics verify that a problem exists." ::= { cpqDaPhyDrvEntry 28 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.232.3.2.5.1.1.1 | cpqDaPhyDrvCntlrIndex | 0 | 0 | Drive Array Physical Drive Controller Index. This index maps the physical drive back to the controller to which it is attached. T… |
1.3.6.1.4.1.232.3.2.5.1.1.2 | cpqDaPhyDrvIndex | 0 | 0 | Drive Array Physical Drive Index. This index is used for selecting the physical drive table entry. This number, along with the cp… |
1.3.6.1.4.1.232.3.2.5.1.1.3 | cpqDaPhyDrvModel | 0 | 0 | Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the … |
1.3.6.1.4.1.232.3.2.5.1.1.4 | cpqDaPhyDrvFWRev | 0 | 0 | Physical Drive Firmware Revision. This shows the physical drive revision number. If the firmware revision is not present, you hav… |
1.3.6.1.4.1.232.3.2.5.1.1.5 | cpqDaPhyDrvBay | 0 | 0 | Physical Drive Bay Location. This value matches the bay location where the physical drive has been installed. Each bay is labele… |
1.3.6.1.4.1.232.3.2.5.1.1.6 | cpqDaPhyDrvStatus | 0 | 0 | Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status:… |
1.3.6.1.4.1.232.3.2.5.1.1.7 | cpqDaPhyDrvFactReallocs | 0 | 0 | This shows the number of spare sectors available for remapping at the time the physical drive was shipped. The physical drive wil… |
1.3.6.1.4.1.232.3.2.5.1.1.8 | cpqDaPhyDrvUsedReallocs | 0 | 0 | Physical Drive Used Reallocated Sectors. This shows the number of sectors of the reallocation area that have been used by the phy… |
1.3.6.1.4.1.232.3.2.5.1.1.9 | cpqDaPhyDrvRefHours | 0 | 0 | Reference Time in hours. This shows the total number of hours that a physical drive has been spinning since the drive was stamped… |
1.3.6.1.4.1.232.3.2.5.1.1.10 | cpqDaPhyDrvHReads | 0 | 0 | Sectors Read (high). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk … |
1.3.6.1.4.1.232.3.2.5.1.1.11 | cpqDaPhyDrvReads | 0 | 0 | Sectors Read (low). The phyDrvHReads and the phyDrvReads together shows the total number of sectors read from the physical disk d… |
1.3.6.1.4.1.232.3.2.5.1.1.12 | cpqDaPhyDrvHWrites | 0 | 0 | Sectors Written (high). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical… |
1.3.6.1.4.1.232.3.2.5.1.1.13 | cpqDaPhyDrvWrites | 0 | 0 | Sectors Written (low). The phyDrvHWrites and the phyDrvWrites together shows the total number of sectors written to the physical d… |
1.3.6.1.4.1.232.3.2.5.1.1.14 | cpqDaPhyDrvHSeeks | 0 | 0 | Total Seeks (high). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the phys… |
1.3.6.1.4.1.232.3.2.5.1.1.15 | cpqDaPhyDrvSeeks | 0 | 0 | Total Seeks (low). The phyDrvHSeeks and the phyDrvSeeks together shows the total number of seek operations performed by the physi… |
1.3.6.1.4.1.232.3.2.5.1.1.16 | cpqDaPhyDrvHardReadErrs | 0 | 0 | Hard Read Errors. This shows the number of read errors that have occurred on a drive that could not be recovered by a physical dr… |
1.3.6.1.4.1.232.3.2.5.1.1.17 | cpqDaPhyDrvRecvReadErrs | 0 | 0 | Recovered Read Errors. This shows the number of read errors corrected through physical drive retries during the reference time (p… |
1.3.6.1.4.1.232.3.2.5.1.1.18 | cpqDaPhyDrvHardWriteErrs | 0 | 0 | Hard Write Errors. This shows the number of write errors that could not be recovered by a physical drive during the reference tim… |
1.3.6.1.4.1.232.3.2.5.1.1.19 | cpqDaPhyDrvRecvWriteErrs | 0 | 0 | Recovered Write Errors. This shows the number of write errors corrected through physical drive retries or recovered by a physical… |
1.3.6.1.4.1.232.3.2.5.1.1.20 | cpqDaPhyDrvHSeekErrs | 0 | 0 | Seek Errors (High). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk dr… |
1.3.6.1.4.1.232.3.2.5.1.1.21 | cpqDaPhyDrvSeekErrs | 0 | 0 | Seek Errors (low). The phyDrvHSeekErrs and the phyDrvSeekErrs together shows the total number of times that the physical disk dri… |
1.3.6.1.4.1.232.3.2.5.1.1.22 | cpqDaPhyDrvSpinupTime | 0 | 0 | Spin up Time in tenths of seconds. This is the time it takes for a physical drive to spin up to full speed. Disks require time to … |
1.3.6.1.4.1.232.3.2.5.1.1.23 | cpqDaPhyDrvFunctTest1 | 0 | 0 | Functional Test 1. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.3.2.5.1.1.24 | cpqDaPhyDrvFunctTest2 | 0 | 0 | Functional Test 2. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.3.2.5.1.1.25 | cpqDaPhyDrvFunctTest3 | 0 | 0 | Functional Test 3. This provides information about a series of tests that indicate how well a physical drive works. These tests c… |
1.3.6.1.4.1.232.3.2.5.1.1.26 | cpqDaPhyDrvDrqTimeouts | 0 | 0 | DRQ Timeouts. The number of times that a physical drive continued to request data, but did not get a command completion during t… |
1.3.6.1.4.1.232.3.2.5.1.1.27 | cpqDaPhyDrvOtherTimeouts | 0 | 0 | Other Timeouts. The number of times that a physical drive did not respond with an interrupt within a controller-defined period of… |
1.3.6.1.4.1.232.3.2.5.1.1.29 | cpqDaPhyDrvBadRecvReads | 0 | 0 | Recovery Failed (Bad) Read Error. The number of times a read error occurred while performing Automatic Data Recovery from this ph… |
1.3.6.1.4.1.232.3.2.5.1.1.30 | cpqDaPhyDrvBadRecvWrites | 0 | 0 | Recovery Failed (Bad) Write Error. The number of times a write error occurred while performing Automatic Data Recovery from anoth… |
1.3.6.1.4.1.232.3.2.5.1.1.31 | cpqDaPhyDrvFormatErrs | 0 | 0 | Format Error. The number of times a format operation failed when the controller attempted to remap a bad sector during the refere… |
1.3.6.1.4.1.232.3.2.5.1.1.32 | cpqDaPhyDrvPostErrs | 0 | 0 | Power On Self Test (Post) Error. The number of times that a physical drive failed its self test during the reference time (phyDrv… |
1.3.6.1.4.1.232.3.2.5.1.1.33 | cpqDaPhyDrvNotReadyErrs | 0 | 0 | Drive Not Ready Errors. The number of times the physical drive failed after the spin up command was issued during the reference t… |
1.3.6.1.4.1.232.3.2.5.1.1.34 | cpqDaPhyDrvReallocAborts | 0 | 0 | Physical Drive Reallocation Aborts. The number of times the physical drive has failed due to an error that occurred when the cont… |
1.3.6.1.4.1.232.3.2.5.1.1.35 | cpqDaPhyDrvThreshPassed | 0 | 0 | Physical Drive Factory Threshold Passed (Exceeded). When the drive is shipped, certain thresholds have been set to monitor perfor… |
1.3.6.1.4.1.232.3.2.5.1.1.36 | cpqDaPhyDrvHasMonInfo | 0 | 0 | Physical Drive Has Monitor Information. All of the physical disk table fields except for the physical disk status (phyDrvStatus) … |
1.3.6.1.4.1.232.3.2.5.1.1.37 | cpqDaPhyDrvCondition | 0 | 0 | The condition of the device. This value represents the overall condition of this physical drive. |
1.3.6.1.4.1.232.3.2.5.1.1.38 | cpqDaPhyDrvHotPlugs | 0 | 0 | Physical Drive Hot Plug Count. This value indicates the number of times this physical drive was hot-plugged (removed) from a ProL… |
1.3.6.1.4.1.232.3.2.5.1.1.39 | cpqDaPhyDrvMediaErrs | 0 | 0 | Physical Drive Media Failure Count. This value indicates the number of times this physical drive was failed due to unrecoverable … |
1.3.6.1.4.1.232.3.2.5.1.1.40 | cpqDaPhyDrvHardwareErrs | 0 | 0 | Physical Drive Hardware Error Count. This value indicates the number of times this physical drive returned a bad hardware status.… |
1.3.6.1.4.1.232.3.2.5.1.1.41 | cpqDaPhyDrvAbortedCmds | 0 | 0 | Physical Drive Aborted Command Failures. This value indicates the number of times this physical drive was failed due to aborted c… |
1.3.6.1.4.1.232.3.2.5.1.1.42 | cpqDaPhyDrvSpinUpErrs | 0 | 0 | Physical Drive Spin-Up Failure Count. This value indicates the number of times this physical drive was failed due to a failure of… |
1.3.6.1.4.1.232.3.2.5.1.1.43 | cpqDaPhyDrvBadTargetErrs | 0 | 0 | Physical Drive Bad Target Count. This value indicates the number of times this physical drive performed some action that did not … |
1.3.6.1.4.1.232.3.2.5.1.1.44 | cpqDaPhyDrvLocation | 0 | 0 | Drive Physical Location. This is the physical location of where the drive is located. The following values are defined: other(1) Th… |
1.3.6.1.4.1.232.3.2.5.1.1.45 | cpqDaPhyDrvSize | 0 | 0 | Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,5… |
1.3.6.1.4.1.232.3.2.5.1.1.46 | cpqDaPhyDrvBusFaults | 0 | 0 | Physical Drive Bus Fault Count. This value indicates the number of times that a bus fault was detected for the drive by the contr… |
1.3.6.1.4.1.232.3.2.5.1.1.47 | cpqDaPhyDrvIrqDeglitches | 0 | 0 | Physical Drive IRQ Deglitch Count. This is not supported by the IDA, IDA Expansion, or IDA-2 controllers. |
1.3.6.1.4.1.232.3.2.5.1.1.48 | cpqDaPhyDrvHotPlug | 0 | 0 | Physical Drive Hot Plug Support Status. The following values are defined: other(1) The Insight Agent is unable to determine if thi… |
1.3.6.1.4.1.232.3.2.5.1.1.49 | cpqDaPhyDrvPlacement | 0 | 0 | Physical Drive Placement. The following values are defined: other(1) The agent is unable to determine if the drive is internal or e… |
1.3.6.1.4.1.232.3.2.5.1.1.50 | cpqDaPhyDrvBusNumber | 0 | 0 | Physical Drive SCSI Bus Number. The bus number indicates to which SCSI bus this physical drive is attached. The first instance i… |
1.3.6.1.4.1.232.3.2.5.1.1.51 | cpqDaPhyDrvSerialNum | 0 | 0 | Physical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial numbe… |
1.3.6.1.4.1.232.3.2.5.1.1.52 | cpqDaPhyDrvPreFailMonitoring | 0 | 0 | Drive Array Physical Drive Predictive Failure Monitoring. The following values are defined: other(1) The agent is unable to determ… |
1.3.6.1.4.1.232.3.2.5.1.1.53 | cpqDaPhyDrvCurrentWidth | 0 | 0 | Drive Array Physical Drive Current Width. The following values are defined: other(1) The agent is unable to determine the current … |
1.3.6.1.4.1.232.3.2.5.1.1.54 | cpqDaPhyDrvCurrentSpeed | 0 | 0 | Drive Array Physical Drive Current Data Transfer Speed. The following values are defined: other(1) The agent is unable to determin… |
1.3.6.1.4.1.232.3.2.5.1.1.55 | cpqDaPhyDrvFailureCode | 0 | 0 | Drive Array Physical Drive Failure Code. This value is the drive failure reason code returned by the array firmware. It is valid… |
1.3.6.1.4.1.232.3.2.5.1.1.56 | cpqDaPhyDrvBlinkTime | 0 | 0 | Physical Drive Blink Time Count. This value indicates the amount of time, in tenths of a second, that the physical drive LEDs wil… |
1.3.6.1.4.1.232.3.2.5.1.1.57 | cpqDaPhyDrvSmartStatus | 0 | 0 | Physical Drive S.M.A.R.T Status. The following values are defined: other(1) The agent is unable to determine if the status of S.M.… |
1.3.6.1.4.1.232.3.2.5.1.1.58 | cpqDaPhyDrvConfigurationStatus | 0 | 0 | Physical Drive Configuration Status. The following values are defined: other(1) The agent is unable to determine the configuration… |
1.3.6.1.4.1.232.3.2.5.1.1.59 | cpqDaPhyDrvRotationalSpeed | 0 | 0 | Drive Array Physical Drive Rotational Speed. The following values are defined: other(1) The agent is unable to determine the rotat… |
1.3.6.1.4.1.232.3.2.5.1.1.60 | cpqDaPhyDrvType | 0 | 0 | Physical Drive Type. The following values are defined: other(1) The agent is unable to determine the type for this drive. parallelS… |
1.3.6.1.4.1.232.3.2.5.1.1.61 | cpqDaPhyDrvSataVersion | 0 | 0 | Physical Drive SATA Version. The following values are defined: other(1) The agent is unable to determine the SATA version for this… |
1.3.6.1.4.1.232.3.2.5.1.1.62 | cpqDaPhyDrvHostConnector | 0 | 0 | Physical Drive Host Connector. This is the host connector to which the drive is ultimately attached. If the host connector canno… |
1.3.6.1.4.1.232.3.2.5.1.1.63 | cpqDaPhyDrvBoxOnConnector | 0 | 0 | Physical Drive Box on Connector. The box on connector indicates to which box instance this physical drive belongs. The instances… |
1.3.6.1.4.1.232.3.2.5.1.1.64 | cpqDaPhyDrvLocationString | 0 | 0 | Physical Drive Location String. This string describes the location of the drive in relation to the controller. If the location s… |
1.3.6.1.4.1.232.3.2.5.1.1.65 | cpqDaPhyDrvNegotiatedLinkRate | 0 | 0 | Drive Array Physical Drive Negotiated Link Rate. The following values are defined: other(1) The agent is unable to determine the n… |
1.3.6.1.4.1.232.3.2.5.1.1.66 | cpqDaPhyDrvNcqSupport | 0 | 0 | Drive Array Physical Drive Native Command Queueing. The following values are defined: other(1) The agent is unable to determine th… |
1.3.6.1.4.1.232.3.2.5.1.1.67 | cpqDaPhyDrvPhyCount | 0 | 0 | Drive Array Physical Drive PHY Count. This value indicates how many PHYs exist on SAS/SATA disk. For parallel SCSI disks, this v… |
1.3.6.1.4.1.232.3.2.5.1.1.68 | cpqDaPhyDrvMultipathAccess | 0 | 0 | Drive Array Physical Drive Multi-path Access Status. This indicates if this physical drive has been configured to have and curren… |
1.3.6.1.4.1.232.3.2.5.1.1.69 | cpqDaPhyDrvMediaType | 0 | 0 | Physical Drive Media Type. The following values are defined: other(1) The instrument agent is unable to determine the physical dri… |