wvInsertTestSignalRemainingStartTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
DESCRIPTION
"Defines the ongoing remaining time before the tests on the lines specified by wvInsertTestSignalLine start."
View at oid-info.com
Defines the ongoing remaining time before the tests on the lines
specified by wvInsertTestSignalLine start.
Parsed from file 8800-DMR.txt
Company: None
Module: CODAN-MIB
Defines the ongoing remaining time before the tests on the lines
specified by wvInsertTestSignalLine start.
Parsed from file CODAN-MIB.mib
Module: CODAN-MIB
wvInsertTestSignalRemainingStartTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the ongoing remaining time before the tests on the lines specified by wvInsertTestSignalLine start." ::= { wvTests 205 }
wvInsertTestSignalRemainingStartTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Defines the ongoing remaining time before the tests on the lines specified by wvInsertTestSignalLine start." ::= { wvTests 205 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.23304.1.1.4.205.0 | wvInsertTestSignalRemainingStartTime | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.23304.1.1.4.1 | wvLoopbackType | 1 | 1 | Defines the type of loopback to be performed on the terminal. |
1.3.6.1.4.1.23304.1.1.4.2 | wvLoopbackStartTime | 1 | 1 | Defines the desired delay time, in time-ticks, before the loopbacks specified by wvLoopbackType are activated. When any loopback … |
1.3.6.1.4.1.23304.1.1.4.3 | wvLoopbackTimePeriod | 1 | 1 | Defines the desired duration of the loopback. Setting a value of 0 means it should run until deliberately stopped. |
1.3.6.1.4.1.23304.1.1.4.4 | wvLoopbackRemainingStartTime | 1 | 1 | Defines the ongoing remaining time before the loopbacks specified by wvLoopbackType are activated. |
1.3.6.1.4.1.23304.1.1.4.5 | wvLoopbackRemainingTimePeriod | 1 | 1 | Defines the ongoing remaining duration of the loopback activation. |
1.3.6.1.4.1.23304.1.1.4.100 | wvSelfTestType | 1 | 1 | Defines the type of next self-tests to be performed on the terminal. Local restrictions may limit the tests that can be performe… |
1.3.6.1.4.1.23304.1.1.4.101 | wvSelfTestStartTime | 1 | 1 | Defines the desired delay time, in time-ticks, before the tests specified by wvSelfTestType are started. When any test is running… |
1.3.6.1.4.1.23304.1.1.4.102 | wvLastSelfTestStartTime | 1 | 1 | Keeps the time, relative to sysUpTime, when the tests in the wvLastSelfTestTable were last performed. |
1.3.6.1.4.1.23304.1.1.4.103 | wvLastSelfTestTable | 1 | 3 | wvLastSelftestTable |
1.3.6.1.4.1.23304.1.1.4.104 | wvSelfTestRemainingStartTime | 1 | 1 | Defines the ongoing remaining time before the tests specified by wvSelfTestType start. |
1.3.6.1.4.1.23304.1.1.4.200 | wvInsertTestSignalLine | 1 | 1 | Defines the line(s) on which a special BER test signal is inserted. Proper loopbacks are assumed to be previously set for the te… |
1.3.6.1.4.1.23304.1.1.4.201 | wvInsertTestSignalStartTime | 1 | 1 | Defines the desired delay time, in time-ticks, before the tests on the lines specified by wvInsertTestSignalLine are started. Whe… |
1.3.6.1.4.1.23304.1.1.4.202 | wvInsertTestSignalTimePeriod | 1 | 1 | Defines the desired duration of the tests. Setting a value of 0 means it should run until deliberately stopped. |
1.3.6.1.4.1.23304.1.1.4.203 | wvLastTestSignalTime | 1 | 1 | Defines the time, relative to sysUpTime, when the insert test signal was last performed. |
1.3.6.1.4.1.23304.1.1.4.204 | wvLastTestSignalBER | 1 | 1 | Specifies the Bit Error Rate from last test signal activation. |
1.3.6.1.4.1.23304.1.1.4.206 | wvInsertTestSignalRemainingTimePeriod | 1 | 1 | Defines the ongoing remaining duration of the tests. |
1.3.6.1.4.1.23304.1.1.4.300 | wvGenericDiagnosticsParameterAddress | 1 | 1 | This object defines the address on the IDU physical memory from which wvGenericDiagnosticsParameterValue below is read. The given… |
1.3.6.1.4.1.23304.1.1.4.301 | wvGenericDiagnosticsParameterValue | 1 | 1 | Reading of this object returns the 4 bytes (long) value on the address specified by wvGenericDiagnosticsParameterAddress above. |