wvGenericDiagnosticsParameterAddress OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
DESCRIPTION
"This object defines the address on the IDU physical memory from which wvGenericDiagnosticsParameterValue below is read.
The given address will be aligned to long, if needed.
Attempt to set it to a non-valid address will be rejected."
View at oid-info.com
This object defines the address on the IDU physical memory
from which wvGenericDiagnosticsParameterValue below is read.
The given address will be aligned to long, if needed.
Attempt to set it to a non-valid address will be rejected.
Parsed from file 8800-DMR.txt
Company: None
Module: CODAN-MIB
This object defines the address on the IDU physical memory
from which wvGenericDiagnosticsParameterValue below is read.
The given address will be aligned to long, if needed.
Attempt to set it to a non-valid address will be rejected.
Parsed from file CODAN-MIB.mib
Module: CODAN-MIB
wvGenericDiagnosticsParameterAddress OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the address on the IDU physical memory from which wvGenericDiagnosticsParameterValue below is read. The given address will be aligned to long, if needed. Attempt to set it to a non-valid address will be rejected." ::= { wvTests 300 }
wvGenericDiagnosticsParameterAddress OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "This object defines the address on the IDU physical memory from which wvGenericDiagnosticsParameterValue below is read. The given address will be aligned to long, if needed. Attempt to set it to a non-valid address will be rejected." ::= { wvTests 300 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.23304.1.1.4.300.0 | wvGenericDiagnosticsParameterAddress | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.23304.1.1.4.1 | wvLoopbackType | 1 | 1 | Defines the type of loopback to be performed on the terminal. |
1.3.6.1.4.1.23304.1.1.4.2 | wvLoopbackStartTime | 1 | 1 | Defines the desired delay time, in time-ticks, before the loopbacks specified by wvLoopbackType are activated. When any loopback … |
1.3.6.1.4.1.23304.1.1.4.3 | wvLoopbackTimePeriod | 1 | 1 | Defines the desired duration of the loopback. Setting a value of 0 means it should run until deliberately stopped. |
1.3.6.1.4.1.23304.1.1.4.4 | wvLoopbackRemainingStartTime | 1 | 1 | Defines the ongoing remaining time before the loopbacks specified by wvLoopbackType are activated. |
1.3.6.1.4.1.23304.1.1.4.5 | wvLoopbackRemainingTimePeriod | 1 | 1 | Defines the ongoing remaining duration of the loopback activation. |
1.3.6.1.4.1.23304.1.1.4.100 | wvSelfTestType | 1 | 1 | Defines the type of next self-tests to be performed on the terminal. Local restrictions may limit the tests that can be performe… |
1.3.6.1.4.1.23304.1.1.4.101 | wvSelfTestStartTime | 1 | 1 | Defines the desired delay time, in time-ticks, before the tests specified by wvSelfTestType are started. When any test is running… |
1.3.6.1.4.1.23304.1.1.4.102 | wvLastSelfTestStartTime | 1 | 1 | Keeps the time, relative to sysUpTime, when the tests in the wvLastSelfTestTable were last performed. |
1.3.6.1.4.1.23304.1.1.4.103 | wvLastSelfTestTable | 1 | 3 | wvLastSelftestTable |
1.3.6.1.4.1.23304.1.1.4.104 | wvSelfTestRemainingStartTime | 1 | 1 | Defines the ongoing remaining time before the tests specified by wvSelfTestType start. |
1.3.6.1.4.1.23304.1.1.4.200 | wvInsertTestSignalLine | 1 | 1 | Defines the line(s) on which a special BER test signal is inserted. Proper loopbacks are assumed to be previously set for the te… |
1.3.6.1.4.1.23304.1.1.4.201 | wvInsertTestSignalStartTime | 1 | 1 | Defines the desired delay time, in time-ticks, before the tests on the lines specified by wvInsertTestSignalLine are started. Whe… |
1.3.6.1.4.1.23304.1.1.4.202 | wvInsertTestSignalTimePeriod | 1 | 1 | Defines the desired duration of the tests. Setting a value of 0 means it should run until deliberately stopped. |
1.3.6.1.4.1.23304.1.1.4.203 | wvLastTestSignalTime | 1 | 1 | Defines the time, relative to sysUpTime, when the insert test signal was last performed. |
1.3.6.1.4.1.23304.1.1.4.204 | wvLastTestSignalBER | 1 | 1 | Specifies the Bit Error Rate from last test signal activation. |
1.3.6.1.4.1.23304.1.1.4.205 | wvInsertTestSignalRemainingStartTime | 1 | 1 | Defines the ongoing remaining time before the tests on the lines specified by wvInsertTestSignalLine start. |
1.3.6.1.4.1.23304.1.1.4.206 | wvInsertTestSignalRemainingTimePeriod | 1 | 1 | Defines the ongoing remaining duration of the tests. |
1.3.6.1.4.1.23304.1.1.4.301 | wvGenericDiagnosticsParameterValue | 1 | 1 | Reading of this object returns the 4 bytes (long) value on the address specified by wvGenericDiagnosticsParameterAddress above. |