The current state of the secondary synchronization PLL.
The 'unusable' state indicates that at the instant the
PLL state was sampled, the PLL output was not usable as
a system timing reference (e.g. the PLL is configured
to use an external reference and that reference is
physically disconnected).
Parsed from file cascade.mib.txt
Company: None
Module: CASCADE-MIB
The current state of the secondary synchronization PLL.
Parsed from file CASCADE-MIB.mib
Module: CASCADE-MIB
Vendor: Cascade Communications Corp.
Module: CASCADE-MIB
[Automatically extracted from oidview.com]
nodeSecondaryPLLOperationalState OBJECT-TYPE SYNTAX INTEGER { active (1), inactive-in-lock (2), unusable (3) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the secondary synchronization PLL. The 'unusable' state indicates that at the instant the PLL state was sampled, the PLL output was not usable as a system timing reference (e.g. the PLL is configured to use an external reference and that reference is physically disconnected)." ::= { node 90 }
nodeSecondaryPLLOperationalState OBJECT-TYPE SYNTAX INTEGER { active (1), down (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the secondary synchronization PLL." ::= { node 90 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.277.1.3.90.0 | nodeSecondaryPLLOperationalState | 0 | 0 | None |
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.277.1.3.40 | nodeDiagNonFatalErrMinor | 1 | 1 | Minor error code of last non-fatal error. |
1.3.6.1.4.1.277.1.3.41 | nodeDiagNonFatalStr | 1 | 1 | Ascii string describing last non-fatal error. |
1.3.6.1.4.1.277.1.3.42 | nodeDiagFatalSource | 1 | 1 | Source who reported last fatal error. |
1.3.6.1.4.1.277.1.3.43 | nodeDiagFatalTime | 1 | 1 | Time the last fatal error was reported. |
1.3.6.1.4.1.277.1.3.44 | nodeDiagFatalErrMajor | 1 | 1 | Major error code of last fatal error. |
1.3.6.1.4.1.277.1.3.45 | nodeDiagFatalErrMinor | 1 | 1 | Minor error code of last fatal error. |
1.3.6.1.4.1.277.1.3.46 | nodeDiagFatalStr | 1 | 1 | Ascii string describing last fatal error. |
1.3.6.1.4.1.277.1.3.47 | nodeDiagFatalReboots | 1 | 1 | Number of times the switch has re-booted since last fatal error was reported. |
1.3.6.1.4.1.277.1.3.48 | nodeDiagFatalAddress | 1 | 1 | Address switch was executing when it encountered fatal error. |
1.3.6.1.4.1.277.1.3.49 | nodeDiagBackgroundPasses | 1 | 1 | Number of passes made by the background diagnostics. |
1.3.6.1.4.1.277.1.3.50 | nodeDiagBackgroundFailures | 1 | 1 | Number of failures discovered by background diagnostics. |
1.3.6.1.4.1.277.1.3.51 | nodeDiagBackgroundSuccesses | 1 | 1 | Number of successful passes by background diagnostics. |
1.3.6.1.4.1.277.1.3.52 | nodeDiagLEDReset | 1 | 1 | Change the node state from marginal to active. Change the LED from yellow to green. |
1.3.6.1.4.1.277.1.3.53 | nodeDiagPowerExtensive | 1 | 1 | Should power on diagnostics do slower, extensive testing, or fast testing? |
1.3.6.1.4.1.277.1.3.54 | nodePortPoll | 1 | 1 | The consolidated port status in response to keep-alive polls. |
1.3.6.1.4.1.277.1.3.55 | nodeMaxTelnetConsole | 1 | 1 | The number of concurrent telnet consoles allowed. The default is 2. The maximum is 5. Set it 0 to disable telnet access. |
1.3.6.1.4.1.277.1.3.56 | nodeConsoleTimeout | 1 | 1 | Idle-logoff timer in minutes. The default is 5 minutes, and the maximum can be set is 60 minutes. To disable idle-logout, set thi… |
1.3.6.1.4.1.277.1.3.57 | nodeConsoleTable | 1 | 6 | A list of active consoles on the node, logged in through telnet or serial port. |
1.3.6.1.4.1.277.1.3.58 | nodePsADiagCode | 1 | 1 | The failure code of the power supply A. A non-zero value indicates one or more failures. Refer to the hardware manual for a des… |
1.3.6.1.4.1.277.1.3.59 | nodePsBDiagCode | 1 | 1 | The failure code of the power supply B. A non-zero value indicates one or more failures. Refer to the hardware manual for a des… |
1.3.6.1.4.1.277.1.3.60 | nodeFrameMemoryUtil | 1 | 1 | The percentage of frame memory utilization on this intelligent card. |
1.3.6.1.4.1.277.1.3.61 | nodeFrameMemoryUsage | 1 | 1 | The frame memory utilization, in terms of free bytes, for this intelligent card. |
1.3.6.1.4.1.277.1.3.62 | nodeCapability | 1 | 1 | The capability of this node. |
1.3.6.1.4.1.277.1.3.63 | nodeSvcLastCallFailure | 1 | 1 | A textual string describing the last call failure. |
1.3.6.1.4.1.277.1.3.64 | nodeRerouteDelay | 1 | 1 | The number of seconds delay between each reroute batch event. |
1.3.6.1.4.1.277.1.3.65 | nodeRerouteCount | 1 | 1 | The number of virtual circuits to request a reroute for duing a single reroute batch event. |
1.3.6.1.4.1.277.1.3.66 | nodeFileTransferRequest | 1 | 1 | This object is used to initiate file transfers to and from the switch. A management station can initiate a file transfer by settt… |
1.3.6.1.4.1.277.1.3.67 | nodeFileTransferStatus | 1 | 1 | The status of the file transfer. |
1.3.6.1.4.1.277.1.3.68 | nodeTime | 1 | 1 | The current wall-clock time that is set on the switch in Universal Coordinated Time (UCT). The value is the number of seconds si… |
1.3.6.1.4.1.277.1.3.69 | nodeBillingAPAddress | 1 | 1 | The IP Address of the Adjunct Billing Processor that is servicing this switch. |
1.3.6.1.4.1.277.1.3.70 | nodeBillingAPUsername | 1 | 1 | The Username of the account on the Adjunct Billing Processor to which usage data will be transferred via FTP. |
1.3.6.1.4.1.277.1.3.71 | nodeBillingAPPassword | 1 | 1 | The Password corresponding to the account identified by nodeBillingAPUsername. A NULL string is returned when read. |
1.3.6.1.4.1.277.1.3.72 | nodeBillingSwAPCommsFailures | 1 | 1 | The number of times that communication from the switch to the Adjunct Billing Processor has failed during the current aggregation… |
1.3.6.1.4.1.277.1.3.73 | nodeBillingTable | 1 | 22 | A table of Billing System managable objects, indexed by service. |
1.3.6.1.4.1.277.1.3.74 | nodeRerouteAlg | 1 | 1 | The number of seconds delay between each reroute batch event. |
1.3.6.1.4.1.277.1.3.75 | nodeADTable | 1 | 14 | A list of Authentication Domain entries. |
1.3.6.1.4.1.277.1.3.76 | nodeOamAlarmDisabled | 1 | 1 | If disabled then don't generate oam alarms for circuits that are down on this switch. |
1.3.6.1.4.1.277.1.3.77 | nodeRefclocksrcTable | 1 | 6 | A list of generators (sources) for the system reference clock on the node. This reference clock is used by the clock generation u… |
1.3.6.1.4.1.277.1.3.78 | nodeRefclockActiveSrc | 1 | 1 | The entry number of the active reference clock source in nodeRefclocksrcTable. If zero, the CGU is in free-running mode or holdov… |
1.3.6.1.4.1.277.1.3.79 | nodeRefclockActiveCGUSlotId | 1 | 1 | The physical slot id of the current master CGU board. |
1.3.6.1.4.1.277.1.3.80 | nodeRefclockActiveCGUMode | 1 | 1 | The clock mode of the current master CGU board. |
1.3.6.1.4.1.277.1.3.81 | nodeInitiateImageBackup | 1 | 1 | When set, copy all of the runtime application images and configuration images to there corresponding backup locations on the hard… |
1.3.6.1.4.1.277.1.3.82 | nodeImageBackupState | 1 | 1 | Provides the current state of the images backup operation. |
1.3.6.1.4.1.277.1.3.83 | nodeInitiateImageRestore | 1 | 1 | When set, copy all of the runtime application images and configuration images from their BACKUP locations on the hard disk to the… |
1.3.6.1.4.1.277.1.3.84 | nodeApplicationTable | 1 | 5 | A list of Application Image Descriptions. |
1.3.6.1.4.1.277.1.3.85 | nodePrimarySyncRefAdminState | 1 | 1 | The requested primary clock synchronization reference source. |
1.3.6.1.4.1.277.1.3.86 | nodePrimarySyncRefOperationalState | 1 | 1 | The actual primary clock synchronization reference source. |
1.3.6.1.4.1.277.1.3.87 | nodeSecondarySyncRefAdminState | 1 | 1 | The requested secondary clock synchronization reference source. |
1.3.6.1.4.1.277.1.3.88 | nodeSecondarySyncRefOperationalState | 1 | 1 | The actual secondary clock synchronization reference source. |
1.3.6.1.4.1.277.1.3.89 | nodePrimaryPLLOperationalState | 1 | 1 | The current state of the primary synchronization PLL. |
1.3.6.1.4.1.277.1.3.91 | nodeExternalClockAOperationalState | 1 | 1 | The current state of the External Clock A reference. |
1.3.6.1.4.1.277.1.3.92 | nodeExternalClockBOperationalState | 1 | 1 | The current state of the External Clock B reference. |
1.3.6.1.4.1.277.1.3.93 | nodePortClockAOperationalState | 1 | 1 | The current state of the Port Clock A reference. |
1.3.6.1.4.1.277.1.3.94 | nodePortClockBOperationalState | 1 | 1 | The current state of the Port Clock B reference. |
1.3.6.1.4.1.277.1.3.95 | nodeExternalTimingSource | 1 | 1 | The reference for the external timing output. |
1.3.6.1.4.1.277.1.3.96 | nodeSyncAutoRestore | 1 | 1 | The configuration of the Synchronization Reference Auto Restoration function. |
1.3.6.1.4.1.277.1.3.97 | nodeExternalClockInterfaceType | 1 | 1 | The interface type of the External Clock references. |
1.3.6.1.4.1.277.1.3.98 | nodeTrapMaskMib | 1 | 1 | The suppression mask for MIB II traps. |
1.3.6.1.4.1.277.1.3.99 | nodeTrapMaskEnterprise | 1 | 1 | The suppression mask for enterprise traps. |
1.3.6.1.4.1.277.1.3.100 | nodeExternalClockOutLBO | 1 | 1 | The line-build-out for the T1 External Clock Output from the switch. Default is 0-133ft. |
1.3.6.1.4.1.277.1.3.101 | nodeActiveTimingRefAdmin | 1 | 1 | This variable controls the indication sent to the IOMs as to which of the two clock references is preferred. Normally, it is lef… |
1.3.6.1.4.1.277.1.3.102 | nodeTimingManualRestore | 1 | 1 | When this variable is written, it causes the system timing hardware to attempt to revert back to the previously-failed-but-since-… |
1.3.6.1.4.1.277.1.3.103 | nodeLanIpMask | 1 | 1 | The inband (Ethernet) interface IP mask. the default is 255.255.255.0 |
1.3.6.1.4.1.277.1.3.104 | nodeBulkStatsCollectorAddress | 1 | 1 | The IP Address of the Bulk Statistics Collector to which bulk statistics data is transferred. |
1.3.6.1.4.1.277.1.3.105 | nodeBulkStatsTransferState | 1 | 1 | This object defines the state of a Bulk Statistics raw file transfer process to the Bulk Statistics Collector identified by the n… |
1.3.6.1.4.1.277.1.3.106 | nodeAuthState | 1 | 1 | Console Login Authentication for this node, enabled or disabled. |
1.3.6.1.4.1.277.1.3.107 | nodeAuthDomainID | 1 | 1 | Authentication Domain ID for this node. |
1.3.6.1.4.1.277.1.3.108 | nodeAuthFailReason | 1 | 1 | Reason for console login authentication failure. |
1.3.6.1.4.1.277.1.3.109 | nodeAuthLoginUser | 1 | 1 | Login user failed to pass console authentication. |
1.3.6.1.4.1.277.1.3.110 | nodeBulkAvgTransportBwUsed | 1 | 1 | This object reports the average amount of bandwidth (in bits per second) that has been used to transport ATM Bulk Statistics data… |
1.3.6.1.4.1.277.1.3.111 | nodeBulkAvgTransportBwBurst | 1 | 1 | This object reports the average transport bandwidth burst rate (in bits per second) obtained to transport ATM Bulk Statistics dat… |
1.3.6.1.4.1.277.1.3.112 | nodeBulkMinTransportBwBurst | 1 | 1 | This object reports the minimum transport bandwidth burst rate (in bits per second) obtained to transport ATM Bulk Statistics dat… |
1.3.6.1.4.1.277.1.3.113 | nodeBulkMaxTransportBwBurst | 1 | 1 | This object reports the maximum transport bandwidth burst rate (in bits per second) obtained to transport ATM Bulk Statistics dat… |
1.3.6.1.4.1.277.1.3.114 | nodeBulkSwAPCommsFailures | 1 | 1 | The number of times that communication from the switch to the ATM Bulk Statistics Adjunct Processor has failed during the current… |
1.3.6.1.4.1.277.1.3.115 | nodePsCStatus | 1 | 1 | The status of the power supply #3. For a detailed explanation for the power supply being either in the down or marginal state, r… |
1.3.6.1.4.1.277.1.3.116 | nodePsCDiagCode | 1 | 1 | The failure code of the power supply #3. A non-zero value indicates one or more failures. Refer to the hardware manual for a de… |
1.3.6.1.4.1.277.1.3.117 | nodeAdminStatus | 1 | 1 | THIS OID IS OBSOLETE. THIS CAN BE REUSED. The desired setting of the switch type indicating whether the switch has two powe… |
1.3.6.1.4.1.277.1.3.118 | nodeOperatingStatus | 1 | 1 | The actual switch type indicating whether the switch has two power supplies (TwoPS) or three (ThreePS). |
1.3.6.1.4.1.277.1.3.119 | nodeTrapSeverity | 1 | 1 | This is an OID placeholder for Trap Variables. All Cascade traps will contain this binding for the severity level of the trap. |
1.3.6.1.4.1.277.1.3.120 | nodeTrapSequenceNumber | 1 | 1 | This is an OID placeholder for Trap Variables. All Cascade traps will contain this binding for the sequence number of the trap. … |
1.3.6.1.4.1.277.1.3.121 | nodeTrapTxRate | 1 | 1 | Defines the number of traps (per second) that the switch is allowed to transmit |
1.3.6.1.4.1.277.1.3.122 | nodeTrapMaskSeverity | 1 | 1 | The suppression mask for trap severity levels. See nodeTrapSeverity. |
1.3.6.1.4.1.277.1.3.123 | nodeAlarmRelayStatus | 1 | 1 | Control of the external CO alarm relays on the SPA. |
1.3.6.1.4.1.277.1.3.124 | nodeTrapsDiscardedMajor | 1 | 1 | The number of Major severity traps that were discarded due to queue full conditions. |
1.3.6.1.4.1.277.1.3.125 | nodeTrapsDiscardedMinor | 1 | 1 | The number of Minor severity traps that were discarded due to queue full conditions. |
1.3.6.1.4.1.277.1.3.126 | nodeTrapDiscardedNonalarm | 1 | 1 | The number of Nonalarm severity traps that were discarded due to queue full conditions. |
1.3.6.1.4.1.277.1.3.127 | nodeNtpExternalPoll | 1 | 1 | The log base2 polling interval at which the active CP/SP shall request a time reference from each external reference time server,… |
1.3.6.1.4.1.277.1.3.128 | nodeNtpLocalPoll | 1 | 1 | The log base2 polling interval at which the IOP/IOM cards and redundant CP/SP shall request a time reference from each reference … |
1.3.6.1.4.1.277.1.3.129 | nodeNtpPreferredServer | 1 | 1 | The IP Address of the preferred reference time server |
1.3.6.1.4.1.277.1.3.130 | nodeNtpSystemStatus | 1 | 1 | The Network Timing Protocol system summary status word Leap Year Indicator 0 no warning 1 last minute has 61 sec 2 last mi… |
1.3.6.1.4.1.277.1.3.131 | nodeNtpSystemEventCount | 1 | 1 | System Event Counter - exceptions since last read freezes at 15 |
1.3.6.1.4.1.277.1.3.132 | nodeNtpSystemEventCode | 1 | 1 | System Event Code - Last Exception Code Reported |
1.3.6.1.4.1.277.1.3.133 | nodeNtpRefTimestampISec | 1 | 1 | nodeNtpReftimestampISec |
1.3.6.1.4.1.277.1.3.134 | nodeNtpRefTimeStampFSec | 1 | 1 | nodeNtpReftimeStampFSec |
1.3.6.1.4.1.277.1.3.135 | nodeNtpOffset | 1 | 1 | Deviation of last Ntp clock update in msec. |
1.3.6.1.4.1.277.1.3.136 | nodeNtpMaxOffset | 1 | 1 | Maximum Deviation between the Ntp clock msec. This value shall be cleared after it is read. |
1.3.6.1.4.1.277.1.3.137 | nodeNtpNumberofUpdates | 1 | 1 | Number of time the local ntp timer clock has been updated by the NTP process since startup. |
1.3.6.1.4.1.277.1.3.138 | nodeNtpReferenceID | 1 | 1 | This is the IP Address of the current time server being referenced |
1.3.6.1.4.1.277.1.3.139 | nodeBulkStatsBaseCollectPeriod | 1 | 1 | Defines the base collection period for Bulk Statistics on the B-STDX 8000/9000 starting with release 4.2. Only the following valu… |
1.3.6.1.4.1.277.1.3.140 | nodeLanIdleTimeout | 1 | 1 | The idle timeout interval, in seconds, for the Ethernet interface. If the Ethernet interface receives no valid IP traffic during… |
... |