Enables or Disables Far end loopback control of the
switch. Enabled (2) = Loop up and down commands from far
end equipment will be processed. Disabled (1) - loop up
and down commands from far end equipment shall be ignored.
This control does not affect the switch's transmission of
loopback commands to the far end
Parsed from file cascade.mib.txt
Company: None
Module: CASCADE-MIB
Enables or Disables Far end loopback control of the
switch. Enabled (2) = Loop up and down commands from far
end equipment will be processed. Disabled (1) - loop up
and down commands from far end equipment shall be ignored.
This control does not affect the switch's transmission of
loopback commands to the far end
Parsed from file CASCADE-MIB.mib
Module: CASCADE-MIB
Vendor: Cascade Communications Corp.
Module: CASCADE-MIB
[Automatically extracted from oidview.com]
pportds1FELoopbackControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or Disables Far end loopback control of the switch. Enabled (2) = Loop up and down commands from far end equipment will be processed. Disabled (1) - loop up and down commands from far end equipment shall be ignored. This control does not affect the switch's transmission of loopback commands to the far end" ::= { pportEntry 148 }
pportds1FELoopbackControl OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables or Disables Far end loopback control of the switch. Enabled (2) = Loop up and down commands from far end equipment will be processed. Disabled (1) - loop up and down commands from far end equipment shall be ignored. This control does not affect the switch's transmission of loopback commands to the far end" ::= { pportEntry 148 }
To many brothers! Only 100 nearest brothers are shown.
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
... | ||||
1.3.6.1.4.1.277.1.4.2.1.98 | pportDS0LpbkMode | 0 | 0 | This determines what mode the DS0 Processor will be set to. 1 - no lpbk 2 - switch lpbk 3 - far end lpbk. |
1.3.6.1.4.1.277.1.4.2.1.99 | pportDS0SwitchLpbkStart | 0 | 0 | This is the first DS0 in a sting of consecutive DS0's to be looped back at the switch if the DS0 processor is set to switch loopb… |
1.3.6.1.4.1.277.1.4.2.1.100 | pportDS0SwitchLpbkEnd | 0 | 0 | This is the Last DS0, +1, in a sting of consecutive DS0's to be looped back at the switch if the DS0 processor is set to switch l… |
1.3.6.1.4.1.277.1.4.2.1.101 | pportDS0FarendDS0InLpbk | 0 | 0 | This indicates the DS0 in far end loopback. |
1.3.6.1.4.1.277.1.4.2.1.102 | pportDS0SendTestTraffic | 0 | 0 | Enable or Disable sending DS0 2047 test pattern for DS0 far end testing. |
1.3.6.1.4.1.277.1.4.2.1.103 | pportOc3LoopConfig | 0 | 0 | The loopback state of the ATM IWU OC3 |
1.3.6.1.4.1.277.1.4.2.1.104 | pportOc3LoopStatus | 0 | 0 | The current loopback status of the ATM IWU OC3 |
1.3.6.1.4.1.277.1.4.2.1.105 | pportISDNIpBaseAddr | 0 | 0 | Specifies the base address used for IP Dynamic Address Assignment |
1.3.6.1.4.1.277.1.4.2.1.106 | pportSonetSTM1Scramble | 0 | 0 | Configured SONET/STM-1 scrambling. |
1.3.6.1.4.1.277.1.4.2.1.107 | pportEFCIMarking | 0 | 0 | Configured EFCI marking for cell traffic in Topaz IOMs |
1.3.6.1.4.1.277.1.4.2.1.108 | pportAtmQOSTransmitMode | 0 | 0 | Select fix priority or weighted round-robin for cell transmission in different ATM QOS classes. |
1.3.6.1.4.1.277.1.4.2.1.109 | pportHECMode | 0 | 0 | Configured ATM HEC single bit error correction routine. |
1.3.6.1.4.1.277.1.4.2.1.110 | pportISDNChannelStatus | 0 | 0 | The ISDN call status of all the B-Channels on the pport are encoded into this 24 character, (for T1 ISDN PRI card...23B+D) or 31… |
1.3.6.1.4.1.277.1.4.2.1.111 | pportds1FarEndLoopStatus | 0 | 0 | DS1 Far End Loopback Status as commanded by the switch |
1.3.6.1.4.1.277.1.4.2.1.112 | pportds1FDLControl | 0 | 0 | Enables or Disables FDL Function for DS1 ESF pport |
1.3.6.1.4.1.277.1.4.2.1.113 | pportds1FDLPrmXmit | 0 | 0 | Enables or Disables transmission of Performance Monitoring Report (PRM) messages on the DS1 ESF FDL |
1.3.6.1.4.1.277.1.4.2.1.114 | pportds1FDLPidXmit | 0 | 0 | Enables or Disables transmission of Path ID (PID) messages on the DS1 ESF FDL |
1.3.6.1.4.1.277.1.4.2.1.115 | pportds1FDLXmitPid | 0 | 0 | Transmit Path Id to be sent on the DS1 ESF FDL. (76 bytes) |
1.3.6.1.4.1.277.1.4.2.1.116 | pportds1FDLRcvPid | 0 | 0 | The last path id message received on the DS1 ESF FDL. (76 bytes) |
1.3.6.1.4.1.277.1.4.2.1.117 | pportds1FDLRcvTsid | 0 | 0 | The last test id message received on the DS1 ESF FDL. (76 bytes) |
1.3.6.1.4.1.277.1.4.2.1.118 | pportSonetSDHFramingMode | 0 | 0 | The Framing mode for SONET/SDH port interface types. |
1.3.6.1.4.1.277.1.4.2.1.119 | pportds1InbandLoopType | 0 | 0 | Integer used to distinguish Inband Line loopback code sent from the switch when commanding inband line loopbacks, and reckognized… |
1.3.6.1.4.1.277.1.4.2.1.120 | pportESFDataLinkStatus | 0 | 0 | The current status of the DS1 ESF (FDL) data link. |
1.3.6.1.4.1.277.1.4.2.1.121 | pportPMTcaId | 0 | 0 | This object identifies the the most recently declared pport threshold crossing alert |
1.3.6.1.4.1.277.1.4.2.1.122 | pportBchanTimerValue | 0 | 0 | This value is used on a per port basis to add a delay to answering a ISDN call of the initial Disconnect from the network. This … |
1.3.6.1.4.1.277.1.4.2.1.123 | pportAAL5CRC32Error | 0 | 0 | Number of received AAL5 packets with CRC32 errors. |
1.3.6.1.4.1.277.1.4.2.1.124 | pportAAL5CPIError | 0 | 0 | Number of received AAL5 packets with CPI errors The only valid value currently defined for the CPI field is all zeros |
1.3.6.1.4.1.277.1.4.2.1.125 | pportAAL5LengthError | 0 | 0 | Number of received AAL5 packets which satisfied one of the following error conditions: 1. number of received cells * 48 bytes - l… |
1.3.6.1.4.1.277.1.4.2.1.126 | pportAAL5ReassemblyTimerError | 0 | 0 | Number of expired reassembly timers |
1.3.6.1.4.1.277.1.4.2.1.127 | pportAAL5MaxNrSegError | 0 | 0 | Number of received AAL5 packets which exceeds the maximum allowed length |
1.3.6.1.4.1.277.1.4.2.1.128 | pportRedundancyArch | 0 | 0 | Pport redundancy architecture. Default is disabled. aps-intracard aps-intercard-resilient-uni cards, resilient UNI is used to rer… |
1.3.6.1.4.1.277.1.4.2.1.129 | pportAPSadminDir | 0 | 0 | Provisioned APS switch-direction-mode. Default is uni- directional. |
1.3.6.1.4.1.277.1.4.2.1.130 | pportAPSlineType | 0 | 0 | APS line type for the pport. Writable only when pportRedundancyArch is disabled. |
1.3.6.1.4.1.277.1.4.2.1.131 | pportAPSrevertiveMode | 0 | 0 | APS revertive mode. When revertive, after the condition for an automatic switchover clears, user traffic will be switched back t… |
1.3.6.1.4.1.277.1.4.2.1.132 | pportAPSpairedSlotId | 0 | 0 | Slot ID of the paired-with APS pport. Writable only when pportRedundancyArch is disabled. |
1.3.6.1.4.1.277.1.4.2.1.133 | pportAPSpairedPportId | 0 | 0 | Pport ID of the paired-with APS pport. Writable only when pportRedundancyARch is disabled. |
1.3.6.1.4.1.277.1.4.2.1.134 | pportAPSsfBerThresh | 0 | 0 | Exponent N for APS Signal Failure based on BER. A line bit-error-rate above 10^-N causes an SF BER failure to be asserted. SF B… |
1.3.6.1.4.1.277.1.4.2.1.135 | pportAPSsdBerThresh | 0 | 0 | Exponent N for APS Signal Degrade based on BER. A line bit-error-rate above 10^-N causes an SD BER failure to be asserted. SD B… |
1.3.6.1.4.1.277.1.4.2.1.136 | pportAPSwtrPeriod | 0 | 0 | APS wait-to-restore period. The number of minutes to wait after an automatic switch condition clears before switching back to th… |
1.3.6.1.4.1.277.1.4.2.1.137 | pportAPSprotectionLineState | 0 | 0 | Indicates the state of the protection line selector. When selected, a protection switchover has taken place and user traffic is b… |
1.3.6.1.4.1.277.1.4.2.1.138 | pportAPSxCommand | 0 | 0 | External switch commands. The clear command clears any previously activated external command. Manual switch is preemptable by a… |
1.3.6.1.4.1.277.1.4.2.1.139 | pportAPSconfigStatus | 0 | 0 | Status of APS pport configuration. The not-configured status indicates the pport APS feature is not configured or it is a non-AP… |
1.3.6.1.4.1.277.1.4.2.1.140 | pportAPSOperRxStatus | 0 | 0 | The current state of the pair of APS pports with respect to the ability of the pair to Receive user traffic. When indicated as u… |
1.3.6.1.4.1.277.1.4.2.1.141 | pportBertPattern | 0 | 0 | Pattern generated by the XBERT |
1.3.6.1.4.1.277.1.4.2.1.142 | pportBertUserBytes | 0 | 0 | Definition of 1,2,3 or 4 byte pattern if UserNByte selected. |
1.3.6.1.4.1.277.1.4.2.1.143 | pportBertErrorRate | 0 | 0 | Error rate to insert in generated pattern. |
1.3.6.1.4.1.277.1.4.2.1.144 | pportBertCommand | 0 | 0 | Single shot commands to the BERT. |
1.3.6.1.4.1.277.1.4.2.1.145 | pportBertStatus | 0 | 0 | Current status of the BERT for this channel. |
1.3.6.1.4.1.277.1.4.2.1.146 | pportBertBitCount | 0 | 0 | The number of bits received - stops counting at 0xFFFFFFFF |
1.3.6.1.4.1.277.1.4.2.1.147 | pportBertErrorCount | 0 | 0 | The number of bits received in error- stops counting at 0xFFFFFFFF |
1.3.6.1.4.1.277.1.4.2.1.149 | pportFT1DS0s | 0 | 0 | DS0 usage bitmask for Fractional T1/E1 data rates. |
1.3.6.1.4.1.277.1.4.2.1.150 | pportIMUXCnt | 0 | 0 | DS3 Inverse Multiplexer counter value - specifies number of idle cells to insert by the outbound process Hardware. |
1.3.6.1.4.1.277.1.4.2.1.151 | pportds1PMConfigThresh | 0 | 0 | The setting determines which standard is used for performance monitoring configuration thresholds |
1.3.6.1.4.1.277.1.4.2.1.152 | pportIdleCellType | 0 | 0 | None |
1.3.6.1.4.1.277.1.4.2.1.153 | pportATMTcaInHECErrorUAlertPeriod | 0 | 0 | ATM tca ingress HEC error uncorrectable alert period (in min.). |
1.3.6.1.4.1.277.1.4.2.1.154 | pportATMTcaInHECErrorUThresh | 0 | 0 | ATM tca ingress HEC error uncorrectable threshold. |
1.3.6.1.4.1.277.1.4.2.1.155 | pportATMTcaEBufOverflowCBRAlertPeriod | 0 | 0 | ATM tca egress buffer overflow CBR Alert period (in min) |
1.3.6.1.4.1.277.1.4.2.1.156 | pportATMTcaEBufOverflowCBRThresh | 0 | 0 | ATM tca egress buffer overflow CBR threshold. |
1.3.6.1.4.1.277.1.4.2.1.157 | pportATMTcaEBufOverflowABRAlertPeriod | 0 | 0 | ATM tca egress buffer overflow ABR alert period (in min) |
1.3.6.1.4.1.277.1.4.2.1.158 | pportATMTcaEBufOverflowABRThresh | 0 | 0 | ATM tca egress buffer overflow ABR threshold. |
1.3.6.1.4.1.277.1.4.2.1.159 | pportATMTcaEBufOverflowVBR1AlertPeriod | 0 | 0 | ATM tca egress buffer overflow VBR1 alert period (in min) |
1.3.6.1.4.1.277.1.4.2.1.160 | pportATMTcaEBufOverflowVBR1Thresh | 0 | 0 | ATM tca egress buffer overflow VBR1 threshold. |
1.3.6.1.4.1.277.1.4.2.1.161 | pportATMTcaEBufOverflowVBR2AlertPeriod | 0 | 0 | ATM tca egress buffer overflow VBR2 alert period (in min) |
1.3.6.1.4.1.277.1.4.2.1.162 | pportATMTcaEBufOverflowVBR2Thresh | 0 | 0 | ATM tca egress buffer overflow VBR2 threshold. |
1.3.6.1.4.1.277.1.4.2.1.163 | pportATMTcaInFramerFIFOOverflowAlertPeriod | 0 | 0 | ATM tca ingress framer FIFO overflow alert period (in min) |
1.3.6.1.4.1.277.1.4.2.1.164 | pportATMTcaInFramerFIFOOverflowThresh | 0 | 0 | ATM tca ingress framer FIFO overflow threshold. |
1.3.6.1.4.1.277.1.4.2.1.165 | pportATMTcaELookupFailureAlertPeriod | 0 | 0 | ATM tca egress lookup failure alert period (in min) |
1.3.6.1.4.1.277.1.4.2.1.166 | pportATMTcaELookupFailureThresh | 0 | 0 | ATM tca egress lookup failure threshold. |
1.3.6.1.4.1.277.1.4.2.1.167 | pportATMTcaEnable | 0 | 0 | ATM tca port enable. |
1.3.6.1.4.1.277.1.4.2.1.168 | pportATMTcaId | 0 | 0 | This object identifies the the most recently declared pport ATM threshold crossing alert |
1.3.6.1.4.1.277.1.4.2.1.169 | pportFethAdminMacAddr, pportFethMacAddr | 0 | 0 | The configured MAC address to use for this Fast Ethernet port. Setting this to all zeros will force the port to use the burned in… |
1.3.6.1.4.1.277.1.4.2.1.170 | pportFethOperMacAddr | 0 | 0 | The actual MAC address in use for this Fast Ethernet port. |
1.3.6.1.4.1.277.1.4.2.1.171 | pportConfigAlarmSoakTime | 0 | 0 | This is the soak time for configurable alarms. An alarm of this type must persist for this period before it is declared. The ti… |
1.3.6.1.4.1.277.1.4.2.1.172 | pportConfigAlarmClearTime | 0 | 0 | This is the soak time for configurable alarms. An alarm of this type must remain clear for this period before it is declared to b… |
1.3.6.1.4.1.277.1.4.2.1.173 | pportFethPortCapability | 0 | 0 | Selection for the speed (10/100) and mode (half/full duplex) of operation for Fast Ethernet ports. |
1.3.6.1.4.1.277.1.4.2.1.174 | pportVpshapingDiscardCellCount | 0 | 0 | Cells discarded due to buffer overflow on this pport because of traffic shaping. |
... |