The number of frames discarded by this port due to excessive transit
delay through the unit. It reports the same value as the object
dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493).
Parsed from file plaintree.mib.txt
Company: None
Module: SWITCH-MIB
The number of frames discarded by this port due to excessive transit
delay through the unit. It reports the same value as the object
dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493).
Parsed from file SWITCH-MIB.mib
Module: SWITCH-MIB
Vendor: PlainTree Systems Inc.
Module: SWITCH-MIB
[Automatically extracted from oidview.com]
portDelayExceededDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames discarded by this port due to excessive transit delay through the unit. It reports the same value as the object dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493)." ::= { portEntry 14 }
portDelayExceededDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames discarded by this port due to excessive transit delay through the unit. It reports the same value as the object dot1dBasePortDelayExceededDiscards in the Bridge MIB (RFC 1493)." ::= { portEntry 14 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.295.3.2.1.2.1.1 | portIndex | 0 | 0 | The number of the port to which the management information applies. |
1.3.6.1.4.1.295.3.2.1.2.1.2 | portProductCode | 0 | 0 | An ASCII string giving the product code of the card on which this port is located. |
1.3.6.1.4.1.295.3.2.1.2.1.3 | portSerialNumber | 0 | 0 | An ASCII string giving the serial number of the card on which this port is located. |
1.3.6.1.4.1.295.3.2.1.2.1.4 | portPlaceOfManufacture | 0 | 0 | A number identifying where the card on which this port is located was built. |
1.3.6.1.4.1.295.3.2.1.2.1.5 | portDateOfManufacture | 0 | 0 | An ASCII string giving the date of manufacture of the card on which this port is located. |
1.3.6.1.4.1.295.3.2.1.2.1.6 | portState | 0 | 0 | An ASCII string giving the port's operational state. |
1.3.6.1.4.1.295.3.2.1.2.1.7 | portHighSensitivity | 0 | 0 | This variable is only valid if the port is an Ethernet port. If this variable is set to TRUE (1), the receiver of the Ethernet NI… |
1.3.6.1.4.1.295.3.2.1.2.1.8 | restoreFddiMibDefaults, portRestoreFddiMibDefaults | 0 | 0 | This variable is ony valid if the port is an FDDI station. Setting this variable to TRUE (1) causes the agent to restore the defa… |
1.3.6.1.4.1.295.3.2.1.2.1.9 | translateAllEthertypes, portTranslateAllEthertypes | 0 | 0 | This variable is only valid if the port is an FDDI port. If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Pro… |
1.3.6.1.4.1.295.3.2.1.2.1.10 | portTxFrames | 0 | 0 | This counter is incremented by one for each frame transmitted to the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.11 | portRxFrames | 0 | 0 | This counter is incremented by one for each valid frame received from the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.12 | portFcsErrors | 0 | 0 | This counter is incremented by one for each received frame which failed its FCS check. |
1.3.6.1.4.1.295.3.2.1.2.1.13 | portFilterDiscards | 0 | 0 | The number of frames received on this port which have been discarded due to the filtering action of the port's bridge circuit. |
1.3.6.1.4.1.295.3.2.1.2.1.15 | portMtuExceededDiscards | 0 | 0 | The number of frames discarded by this port due to excessive size. It is the same value reported in the object dot1dBasePortMtuEx… |
1.3.6.1.4.1.295.3.2.1.2.1.16 | portFddiTooLongNonIpFrames | 0 | 0 | The number of unfragmentable (non-IP) frames greater than ethernet length (1514 bytes) discarded by this port. This object is v… |
1.3.6.1.4.1.295.3.2.1.2.1.17 | portConnected | 0 | 0 | The variable is TRUE (1) if the port is connected to a network segment. The variable is FALSE (0) if the port is not connected t… |
1.3.6.1.4.1.295.3.2.1.2.1.18 | portError | 0 | 0 | The variable is TRUE (1) if the port error lamp is illuminated. The variable is FALSE (0) if the port error lamp is extinguished. |
1.3.6.1.4.1.295.3.2.1.2.1.19 | portBpeEnabled | 0 | 0 | Setting this variable to TRUE (1) causes the bridge protocol engine to perform the Spanning Tree Protocol on the specified port … |
1.3.6.1.4.1.295.3.2.1.2.1.20 | portFastEtherTxValidBytes | 0 | 0 | This counter is incremented by one for each byte of every valid frame transmitted to the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.21 | portFastEtherRxValidBytes | 0 | 0 | This counter is incremented by one for each byte of every valid frame received from the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.22 | portFastEtherFullDuplexEnabled | 0 | 0 | This variable is only valid if the port is a Fast Ethernet 100Base-TX port. If this variable is set to TRUE (1), the Fast Ethern… |
1.3.6.1.4.1.295.3.2.1.2.1.23 | portFrameLossIncidents | 0 | 0 | The number of incidents of one or more frames not forwarded to the port due to lack of resources. |
1.3.6.1.4.1.295.3.2.1.2.1.24 | portHardwareFunctionDescriptor | 0 | 0 | An ASCII string giving the hardware type and revision of the port |