Setting this variable to TRUE (1) causes the bridge protocol engine
to perform the Spanning Tree Protocol on the specified port as
defined in IEEE802.1d. Setting this variable to FALSE (0) causes
the BPE to stop performing the Spanning Tree Protocol on the
specified port. The value of this variable when the unit starts
operating is 1.
Parsed from file plaintree.mib.txt
Company: plaintree
Module: SWITCH-MIB
Vendor: Computer Associates
Module: SWITCH-MIB (SWITCH.MIB)
Type: TABULAR
Access: read-write
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
portBpeEnabled OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this variable to TRUE (1) causes the bridge protocol engine to perform the Spanning Tree Protocol on the specified port as defined in IEEE802.1d. Setting this variable to FALSE (0) causes the BPE to stop performing the Spanning Tree Protocol on the specified port. The value of this variable when the unit starts operating is 1." ::= { portEntry 19 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.295.3.2.1.2.1.1 | portIndex | 0 | 0 | The number of the port to which the management information applies. |
1.3.6.1.4.1.295.3.2.1.2.1.2 | portProductCode | 0 | 0 | An ASCII string giving the product code of the card on which this port is located. |
1.3.6.1.4.1.295.3.2.1.2.1.3 | portSerialNumber | 0 | 0 | An ASCII string giving the serial number of the card on which this port is located. |
1.3.6.1.4.1.295.3.2.1.2.1.4 | portPlaceOfManufacture | 0 | 0 | A number identifying where the card on which this port is located was built. |
1.3.6.1.4.1.295.3.2.1.2.1.5 | portDateOfManufacture | 0 | 0 | An ASCII string giving the date of manufacture of the card on which this port is located. |
1.3.6.1.4.1.295.3.2.1.2.1.6 | portState | 0 | 0 | An ASCII string giving the port's operational state. |
1.3.6.1.4.1.295.3.2.1.2.1.7 | portHighSensitivity | 0 | 0 | This variable is only valid if the port is an Ethernet port. If this variable is set to TRUE (1), the receiver of the Ethernet NI… |
1.3.6.1.4.1.295.3.2.1.2.1.8 | restoreFddiMibDefaults, portRestoreFddiMibDefaults | 0 | 0 | This variable is ony valid if the port is an FDDI station. Setting this variable to TRUE (1) causes the agent to restore the defa… |
1.3.6.1.4.1.295.3.2.1.2.1.9 | translateAllEthertypes, portTranslateAllEthertypes | 0 | 0 | This variable is only valid if the port is an FDDI port. If this variable is set to TRUE (1), the Bridge Tunnel Encapsulation Pro… |
1.3.6.1.4.1.295.3.2.1.2.1.10 | portTxFrames | 0 | 0 | This counter is incremented by one for each frame transmitted to the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.11 | portRxFrames | 0 | 0 | This counter is incremented by one for each valid frame received from the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.12 | portFcsErrors | 0 | 0 | This counter is incremented by one for each received frame which failed its FCS check. |
1.3.6.1.4.1.295.3.2.1.2.1.13 | portFilterDiscards | 0 | 0 | The number of frames received on this port which have been discarded due to the filtering action of the port's bridge circuit. |
1.3.6.1.4.1.295.3.2.1.2.1.14 | portDelayExceededDiscards | 0 | 0 | The number of frames discarded by this port due to excessive transit delay through the unit. It reports the same value as the o… |
1.3.6.1.4.1.295.3.2.1.2.1.15 | portMtuExceededDiscards | 0 | 0 | The number of frames discarded by this port due to excessive size. It is the same value reported in the object dot1dBasePortMtuEx… |
1.3.6.1.4.1.295.3.2.1.2.1.16 | portFddiTooLongNonIpFrames | 0 | 0 | The number of unfragmentable (non-IP) frames greater than ethernet length (1514 bytes) discarded by this port. This object is v… |
1.3.6.1.4.1.295.3.2.1.2.1.17 | portConnected | 0 | 0 | The variable is TRUE (1) if the port is connected to a network segment. The variable is FALSE (0) if the port is not connected t… |
1.3.6.1.4.1.295.3.2.1.2.1.18 | portError | 0 | 0 | The variable is TRUE (1) if the port error lamp is illuminated. The variable is FALSE (0) if the port error lamp is extinguished. |
1.3.6.1.4.1.295.3.2.1.2.1.20 | portFastEtherTxValidBytes | 0 | 0 | This counter is incremented by one for each byte of every valid frame transmitted to the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.21 | portFastEtherRxValidBytes | 0 | 0 | This counter is incremented by one for each byte of every valid frame received from the network segment attached to the port. |
1.3.6.1.4.1.295.3.2.1.2.1.22 | portFastEtherFullDuplexEnabled | 0 | 0 | This variable is only valid if the port is a Fast Ethernet 100Base-TX port. If this variable is set to TRUE (1), the Fast Ethern… |
1.3.6.1.4.1.295.3.2.1.2.1.23 | portFrameLossIncidents | 0 | 0 | The number of incidents of one or more frames not forwarded to the port due to lack of resources. |