Reference record for OID 1.3.6.1.4.1.318.1.1.1.5.2.11



parent
1.3.6.1.4.1.318.1.1.1.5.2 (upsAdvConfig)
node code
11
node name
upsAdvConfigUpsSleepTime
dot oid
1.3.6.1.4.1.318.1.1.1.5.2.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsConfig(5) upsAdvConfig(2) upsAdvConfigUpsSleepTime(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsConfig(5) upsAdvConfig(2) upsAdvConfigUpsSleepTime(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsConfig(5) upsAdvConfig(2) upsAdvConfigUpsSleepTime(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsConfig(5) upsAdvConfig(2) upsAdvConfigUpsSleepTime(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) apc(318) products(1) hardware(1) ups(1) upsConfig(5) upsAdvConfig(2) upsAdvConfigUpsSleepTime(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) apc(318) products(1) hardware(1) ups(1) upsConfig(5) upsAdvConfig(2) upsAdvConfigUpsSleepTime(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsConfig/upsAdvConfig/upsAdvConfigUpsSleepTime
  • /iso/identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsConfig/upsAdvConfig/upsAdvConfigUpsSleepTime
  • /iso/org/dod/internet/private/enterprise/apc/products/hardware/ups/upsConfig/upsAdvConfig/upsAdvConfigUpsSleepTime
  • /iso/org/dod/internet/private/enterprises/apc/products/hardware/ups/upsConfig/upsAdvConfig/upsAdvConfigUpsSleepTime
  • /iso/iso-identified-organization/dod/internet/private/enterprise/apc/products/hardware/ups/upsConfig/upsAdvConfig/upsAdvConfigUpsSleepTime
  • /iso/iso-identified-organization/dod/internet/private/enterprises/apc/products/hardware/ups/upsConfig/upsAdvConfig/upsAdvConfigUpsSleepTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/318/1/1/1/5/2/11

    Description by mibdepot

    The time in seconds for the UPS to go to 'sleep' when
    instructed. When in sleep mode, the UPS will not provide
    output power regardless of the input line state. Once the
    specified time has elapsed, output power will be restored.

    This is a configuration setting. The UPS will not go to
    sleep until told to do so by the manager from a management
    station.

    Any input value is allowed, however the UPS only recognizes
    1/10 of an hour increments. The provided value will be
    rounded to the closest 1/10 of an hour with one exception:
    Any value entered between 1 and 540 seconds will be rounded
    to 360 seconds (or 6 minutes).

    Parsed from file powernet.mib.txt
    Company: None
    Module: PowerNet-MIB

    Description by circitor

    The time in seconds for the UPS to go to 'sleep' when
    instructed. When in sleep mode, the UPS will not provide
    output power regardless of the input line state. Once the
    specified time has elapsed, output power will be restored.

    This is a configuration setting. The UPS will not go to
    sleep until told to do so by the manager from a management
    station.

    Any input value is allowed, however the UPS only recognizes
    1/10 of an hour increments. The provided value will be
    rounded to the closest 1/10 of an hour with one exception:
    Any value entered between 1 and 540 seconds will be rounded
    to 360 seconds (or 6 minutes).

    Parsed from file PowerNet-MIB.mib
    Module: PowerNet-MIB

    Information by mibdepot

    upsAdvConfigUpsSleepTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 1/10 of an hour increments. The provided value will be rounded to the closest 1/10 of an hour with one exception: Any value entered between 1 and 540 seconds will be rounded to 360 seconds (or 6 minutes)." ::= { upsAdvConfig 11 }

    Information by oid_info

    Vendor: American Power Conversion Corp.
    Module: PowerNet-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    upsAdvConfigUpsSleepTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power regardless of the input line state. Once the specified time has elapsed, output power will be restored. This is a configuration setting. The UPS will not go to sleep until told to do so by the manager from a management station. Any input value is allowed, however the UPS only recognizes 1/10 of an hour increments. The provided value will be rounded to the closest 1/10 of an hour with one exception: Any value entered between 1 and 540 seconds will be rounded to 360 seconds (or 6 minutes)." ::= { upsAdvConfig 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.318)

    Yoest Peter C.

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.5.2.11.0 upsAdvConfigUpsSleepTime 0 0 None

    Brothers (47)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.318.1.1.1.5.2.1 upsAdvConfigRatedOutputVoltage 1 1 The nominal output voltage from the UPS in VAC.

    For a list of allowed values supported by your UPS model,
    see the UPS User's Manu…
    1.3.6.1.4.1.318.1.1.1.5.2.2 upsAdvConfigHighTransferVolt 1 1 upsAdvConfigHightransferVolt
    1.3.6.1.4.1.318.1.1.1.5.2.3 upsAdvConfigLowTransferVolt 1 1 The minimum line voltage in VAC allowed before the
    UPS system transfers to battery backup.

    For a list of allowed values supporte…
    1.3.6.1.4.1.318.1.1.1.5.2.4 upsAdvConfigAlarm 1 1 A flag indicating how the UPS should handle audible
    line fail alarms.
    1.3.6.1.4.1.318.1.1.1.5.2.5 upsAdvConfigAlarmTimer 1 1 The time after initial line failure at which the UPS
    begins emitting audible alarms (beeping). This timer is
    observed only if th…
    1.3.6.1.4.1.318.1.1.1.5.2.6 upsAdvConfigMinReturnCapacity 1 1 The minimum battery capacity required before the UPS will
    return from a low battery shutdown condition. The capacity is
    measured…
    1.3.6.1.4.1.318.1.1.1.5.2.7 upsAdvConfigSensitivity 1 1 The sensitivity of the UPS to utility line abnormalities
    or noises.
    1.3.6.1.4.1.318.1.1.1.5.2.8 upsAdvConfigLowBatteryRunTime 1 1 The desired run time of the UPS, in seconds, once the
    low battery condition is reached. Allowed values are 120,
    300, 420, or 600…
    1.3.6.1.4.1.318.1.1.1.5.2.9 upsAdvConfigReturnDelay 1 1 The delay in seconds after utility line power returns
    before the UPS will turn on. This value is also used
    when the UPS comes ou…
    1.3.6.1.4.1.318.1.1.1.5.2.10 upsAdvConfigShutoffDelay 1 1 The delay in seconds the UPS remains on after being told
    to turn off. Allowed values are 20, 180, 300, and
    600 seconds.

    If a valu…
    1.3.6.1.4.1.318.1.1.1.5.2.12 upsAdvConfigSetEEPROMDefaults 1 1 WRITE: Resets the UPS EEPROM variables to default values.
    READ: returns 0
    1.3.6.1.4.1.318.1.1.1.5.2.13 upsAdvConfigDipSwitchTable, upsAdvConfigDipSwitchSetting 1 3 upsAdvConfigDipSwitchtable
    1.3.6.1.4.1.318.1.1.1.5.2.14 upsAdvConfigBattExhaustThresh 1 1 The number of seconds prior to battery exhaustion when the
    UPS will switch off power to its load.
    1.3.6.1.4.1.318.1.1.1.5.2.15 upsAdvConfigPassword 1 1 The password entered at the UPS front panel to enable local
    configuation of the EEProm. If the password is disabled or
    is not sup…
    1.3.6.1.4.1.318.1.1.1.5.2.16 upsAdvConfigAllowedSetTable 1 4 The table listing the allowed values for all discrete
    configurable UPS variables.
    1.3.6.1.4.1.318.1.1.1.5.2.17 upsAdvConfigBattCabAmpHour 1 1 Configure the amp-hour setting of the UPS battery cabinet.
    1.3.6.1.4.1.318.1.1.1.5.2.18 upsAdvConfigPositionSelector 1 1 Configure UPS position selector. If the UPS doesn't
    support this configuration it will report unknown (1).
    The positions are eit…
    1.3.6.1.4.1.318.1.1.1.5.2.19 upsAdvConfigOutputFreqRange 1 1 Configure the output frequency tolerance range.
    unknown(1) indicates the output frequency is unknown.
    freqRangeAUTO(2) configure …
    1.3.6.1.4.1.318.1.1.1.5.2.20 upsAdvConfigUPSFail 1 1 Configure the UPS fail action. If UPS fails,
    and frequency or voltage is out of range it will either
    GotoBypass (2) or DropLoad …
    1.3.6.1.4.1.318.1.1.1.5.2.21 upsAdvConfigAlarmRedundancy 1 1 Configure settings of UPS alarm if the redundancy is
    under the current redundancy. Use 0 for never.
    1.3.6.1.4.1.318.1.1.1.5.2.22 upsAdvConfigAlarmLoadOver 1 1 Configure settings of UPS alarm if the load is
    over the current load in kVA. Use -1 for never.
    1.3.6.1.4.1.318.1.1.1.5.2.23 upsAdvConfigAlarmRuntimeUnder 1 1 Configure settings of UPS alarm if the runtime is
    under the current time of minutes. Use -1 for never.
    1.3.6.1.4.1.318.1.1.1.5.2.24 upsAdvConfigVoutReporting 1 1 Configure the way the UPS scales its output voltage readings.
    unknown(1) indicates the Vout Reporting is unknown.
    voutAUTO(2) con…
    1.3.6.1.4.1.318.1.1.1.5.2.25 upsAdvConfigNumExternalBatteries 1 1 Configure the number of external batteries connected to the UPS.
    1.3.6.1.4.1.318.1.1.1.5.2.26 upsAdvConfigSimpleSignalShutdowns 1 1 Configure Simple Signal shutdown commands from the Simple Signal
    port to be issued to the UPS.
    unknown(1) indicates the Simple Si…
    1.3.6.1.4.1.318.1.1.1.5.2.27 upsAdvConfigMaxShutdownTime 1 1 The maximum amount of time for server shutdown to complete before a
    UPS shutdown occurs.
    1.3.6.1.4.1.318.1.1.1.5.2.28 upsAsiUpsControlServerRequestShutdown 1 1 Start a server shutdown sequence:
    serverShutdownOff: Shutdown server and turn off UPS
    serverShutdownReboot: Shutdown server and t…
    1.3.6.1.4.1.318.1.1.1.5.2.29 upsAdvConfigMinReturnRuntime 1 1 The minimum amount of run time in seconds required before the output will be
    turned on, using power calculation captured at star…
    1.3.6.1.4.1.318.1.1.1.5.2.30 upsAdvConfigBasicSignalLowBatteryDuration 1 1 The duration of runtime in seconds during an on-battery condition at which
    the UPS will signal the basic low battery shutdown co…
    1.3.6.1.4.1.318.1.1.1.5.2.31 upsAdvConfigBypassPhaseLockRequired 1 1 Sets the condition for when bypass is an acceptable mode of operation as a
    requirement.
    1.3.6.1.4.1.318.1.1.1.5.2.32 upsAdvConfigOutputFreqSlewRate 1 1 The rate at which the UPS will change its output frequency
    in response to utility frequency changes.
    1.3.6.1.4.1.318.1.1.1.5.2.33 upsAdvConfigChargerLevel 1 1 Sets the rate at which the UPS charges its batteries.
    1.3.6.1.4.1.318.1.1.1.5.2.34 upsAdvConfigBypassToleranceSetting 1 1 This setting allows selecting from standard bypass tolerance configurations to suit their situation.
    1.3.6.1.4.1.318.1.1.1.5.2.35 upsAdvConfigMainsSetting 1 1 Configure the type of mains supply system.
    singleInput (1) indicates a single supply system.
    dualInput (2) indicates a dual sup…
    1.3.6.1.4.1.318.1.1.1.5.2.36 upsAdvConfigACWiringSetting 1 1 Configure the AC wiring of the system.
    threeWire (1) indicates 3-wire system configuration.
    fourWire (2) indicates 4-wire system…
    1.3.6.1.4.1.318.1.1.1.5.2.37 upsAdvConfigUpperOutputVoltTolerance 1 1 Upper tolerance of the output RMS voltage before transferring to bypass.
    Expressed as percent of nominal voltage.
    1.3.6.1.4.1.318.1.1.1.5.2.38 upsAdvConfigLowerOutputVoltTolerance 1 1 Lower tolerance of the output RMS voltage before transferring to bypass.
    Expressed as percent of nominal voltage.
    1.3.6.1.4.1.318.1.1.1.5.2.39 upsAdvConfigUpperBypassVoltTolerance 1 1 Upper tolerance of the bypass voltage that allows transfer to bypass by user.
    Expressed as percent of nominal voltage.
    1.3.6.1.4.1.318.1.1.1.5.2.40 upsAdvConfigLowerBypassVoltTolerance 1 1 Lower tolerance of the bypass voltage that allows transfer to bypass by user.
    Expressed as percent of nominal voltage.
    1.3.6.1.4.1.318.1.1.1.5.2.41 upsAdvConfigOutofSyncBypassTransferDelay 1 1 Configure the time (in milliseconds), indicating the gap in output voltage
    if an asynchronous transfer to bypass needs to occur.
    1.3.6.1.4.1.318.1.1.1.5.2.43 upsAdvConfigWarningAlarmDelay 0 0 Configure the time delay for reporting warning alarms
    (in seconds).
    1.3.6.1.4.1.318.1.1.1.5.2.44 upsAdvConfigInformationalAlarmDelay 0 0 Configure the time delay for reporting informational alarms
    (in seconds).
    1.3.6.1.4.1.318.1.1.1.5.2.45 upsAdvConfigGreenMode 0 0 Enable/Disable UPS green mode feature.
    1.3.6.1.4.1.318.1.1.1.5.2.46 upsAdvConfigLCDLocalLanguage 0 0 Configure the language setting of the UPS LCD display information.
    1.3.6.1.4.1.318.1.1.1.5.2.47 upsAdvConfigLCDLockOut 0 0 Enable/Disable the control function of the UPS via the LCD Display.
    1.3.6.1.4.1.318.1.1.1.5.2.48 upsAdvConfigChargerRate 0 0 Change the maximum allowed UPS charge rate on select products where 100% represents
    the manufacturer's recommended rate. A char…
    1.3.6.1.4.1.318.1.1.1.5.2.49 upsAdvConfigBatterySelection 0 0 Configure the installed battery type on select products where VRLA is Valve Regulated
    Lead Acid type battery and Vented Cell is …