Configure the time delay for reporting informational alarms
(in seconds).
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Configure the time delay for reporting informational alarms
(in seconds).
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
upsAdvConfigInformationalAlarmDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Configure the time delay for reporting informational alarms (in seconds)." ::= { upsAdvConfig 44 }
upsAdvConfigInformationalAlarmDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Configure the time delay for reporting informational alarms (in seconds)." ::= { upsAdvConfig 44 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.1.5.2.1 | upsAdvConfigRatedOutputVoltage | 1 | 1 | The nominal output voltage from the UPS in VAC. For a list of allowed values supported by your UPS model, see the UPS User's Manu… |
1.3.6.1.4.1.318.1.1.1.5.2.2 | upsAdvConfigHighTransferVolt | 1 | 1 | upsAdvConfigHightransferVolt |
1.3.6.1.4.1.318.1.1.1.5.2.3 | upsAdvConfigLowTransferVolt | 1 | 1 | The minimum line voltage in VAC allowed before the UPS system transfers to battery backup. For a list of allowed values supporte… |
1.3.6.1.4.1.318.1.1.1.5.2.4 | upsAdvConfigAlarm | 1 | 1 | A flag indicating how the UPS should handle audible line fail alarms. |
1.3.6.1.4.1.318.1.1.1.5.2.5 | upsAdvConfigAlarmTimer | 1 | 1 | The time after initial line failure at which the UPS begins emitting audible alarms (beeping). This timer is observed only if th… |
1.3.6.1.4.1.318.1.1.1.5.2.6 | upsAdvConfigMinReturnCapacity | 1 | 1 | The minimum battery capacity required before the UPS will return from a low battery shutdown condition. The capacity is measured… |
1.3.6.1.4.1.318.1.1.1.5.2.7 | upsAdvConfigSensitivity | 1 | 1 | The sensitivity of the UPS to utility line abnormalities or noises. |
1.3.6.1.4.1.318.1.1.1.5.2.8 | upsAdvConfigLowBatteryRunTime | 1 | 1 | The desired run time of the UPS, in seconds, once the low battery condition is reached. Allowed values are 120, 300, 420, or 600… |
1.3.6.1.4.1.318.1.1.1.5.2.9 | upsAdvConfigReturnDelay | 1 | 1 | The delay in seconds after utility line power returns before the UPS will turn on. This value is also used when the UPS comes ou… |
1.3.6.1.4.1.318.1.1.1.5.2.10 | upsAdvConfigShutoffDelay | 1 | 1 | The delay in seconds the UPS remains on after being told to turn off. Allowed values are 20, 180, 300, and 600 seconds. If a valu… |
1.3.6.1.4.1.318.1.1.1.5.2.11 | upsAdvConfigUpsSleepTime | 1 | 1 | The time in seconds for the UPS to go to 'sleep' when instructed. When in sleep mode, the UPS will not provide output power rega… |
1.3.6.1.4.1.318.1.1.1.5.2.12 | upsAdvConfigSetEEPROMDefaults | 1 | 1 | WRITE: Resets the UPS EEPROM variables to default values. READ: returns 0 |
1.3.6.1.4.1.318.1.1.1.5.2.13 | upsAdvConfigDipSwitchTable, upsAdvConfigDipSwitchSetting | 1 | 3 | upsAdvConfigDipSwitchtable |
1.3.6.1.4.1.318.1.1.1.5.2.14 | upsAdvConfigBattExhaustThresh | 1 | 1 | The number of seconds prior to battery exhaustion when the UPS will switch off power to its load. |
1.3.6.1.4.1.318.1.1.1.5.2.15 | upsAdvConfigPassword | 1 | 1 | The password entered at the UPS front panel to enable local configuation of the EEProm. If the password is disabled or is not sup… |
1.3.6.1.4.1.318.1.1.1.5.2.16 | upsAdvConfigAllowedSetTable | 1 | 4 | The table listing the allowed values for all discrete configurable UPS variables. |
1.3.6.1.4.1.318.1.1.1.5.2.17 | upsAdvConfigBattCabAmpHour | 1 | 1 | Configure the amp-hour setting of the UPS battery cabinet. |
1.3.6.1.4.1.318.1.1.1.5.2.18 | upsAdvConfigPositionSelector | 1 | 1 | Configure UPS position selector. If the UPS doesn't support this configuration it will report unknown (1). The positions are eit… |
1.3.6.1.4.1.318.1.1.1.5.2.19 | upsAdvConfigOutputFreqRange | 1 | 1 | Configure the output frequency tolerance range. unknown(1) indicates the output frequency is unknown. freqRangeAUTO(2) configure … |
1.3.6.1.4.1.318.1.1.1.5.2.20 | upsAdvConfigUPSFail | 1 | 1 | Configure the UPS fail action. If UPS fails, and frequency or voltage is out of range it will either GotoBypass (2) or DropLoad … |
1.3.6.1.4.1.318.1.1.1.5.2.21 | upsAdvConfigAlarmRedundancy | 1 | 1 | Configure settings of UPS alarm if the redundancy is under the current redundancy. Use 0 for never. |
1.3.6.1.4.1.318.1.1.1.5.2.22 | upsAdvConfigAlarmLoadOver | 1 | 1 | Configure settings of UPS alarm if the load is over the current load in kVA. Use -1 for never. |
1.3.6.1.4.1.318.1.1.1.5.2.23 | upsAdvConfigAlarmRuntimeUnder | 1 | 1 | Configure settings of UPS alarm if the runtime is under the current time of minutes. Use -1 for never. |
1.3.6.1.4.1.318.1.1.1.5.2.24 | upsAdvConfigVoutReporting | 1 | 1 | Configure the way the UPS scales its output voltage readings. unknown(1) indicates the Vout Reporting is unknown. voutAUTO(2) con… |
1.3.6.1.4.1.318.1.1.1.5.2.25 | upsAdvConfigNumExternalBatteries | 1 | 1 | Configure the number of external batteries connected to the UPS. |
1.3.6.1.4.1.318.1.1.1.5.2.26 | upsAdvConfigSimpleSignalShutdowns | 1 | 1 | Configure Simple Signal shutdown commands from the Simple Signal port to be issued to the UPS. unknown(1) indicates the Simple Si… |
1.3.6.1.4.1.318.1.1.1.5.2.27 | upsAdvConfigMaxShutdownTime | 1 | 1 | The maximum amount of time for server shutdown to complete before a UPS shutdown occurs. |
1.3.6.1.4.1.318.1.1.1.5.2.28 | upsAsiUpsControlServerRequestShutdown | 1 | 1 | Start a server shutdown sequence: serverShutdownOff: Shutdown server and turn off UPS serverShutdownReboot: Shutdown server and t… |
1.3.6.1.4.1.318.1.1.1.5.2.29 | upsAdvConfigMinReturnRuntime | 1 | 1 | The minimum amount of run time in seconds required before the output will be turned on, using power calculation captured at star… |
1.3.6.1.4.1.318.1.1.1.5.2.30 | upsAdvConfigBasicSignalLowBatteryDuration | 1 | 1 | The duration of runtime in seconds during an on-battery condition at which the UPS will signal the basic low battery shutdown co… |
1.3.6.1.4.1.318.1.1.1.5.2.31 | upsAdvConfigBypassPhaseLockRequired | 1 | 1 | Sets the condition for when bypass is an acceptable mode of operation as a requirement. |
1.3.6.1.4.1.318.1.1.1.5.2.32 | upsAdvConfigOutputFreqSlewRate | 1 | 1 | The rate at which the UPS will change its output frequency in response to utility frequency changes. |
1.3.6.1.4.1.318.1.1.1.5.2.33 | upsAdvConfigChargerLevel | 1 | 1 | Sets the rate at which the UPS charges its batteries. |
1.3.6.1.4.1.318.1.1.1.5.2.34 | upsAdvConfigBypassToleranceSetting | 1 | 1 | This setting allows selecting from standard bypass tolerance configurations to suit their situation. |
1.3.6.1.4.1.318.1.1.1.5.2.35 | upsAdvConfigMainsSetting | 1 | 1 | Configure the type of mains supply system. singleInput (1) indicates a single supply system. dualInput (2) indicates a dual sup… |
1.3.6.1.4.1.318.1.1.1.5.2.36 | upsAdvConfigACWiringSetting | 1 | 1 | Configure the AC wiring of the system. threeWire (1) indicates 3-wire system configuration. fourWire (2) indicates 4-wire system… |
1.3.6.1.4.1.318.1.1.1.5.2.37 | upsAdvConfigUpperOutputVoltTolerance | 1 | 1 | Upper tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage. |
1.3.6.1.4.1.318.1.1.1.5.2.38 | upsAdvConfigLowerOutputVoltTolerance | 1 | 1 | Lower tolerance of the output RMS voltage before transferring to bypass. Expressed as percent of nominal voltage. |
1.3.6.1.4.1.318.1.1.1.5.2.39 | upsAdvConfigUpperBypassVoltTolerance | 1 | 1 | Upper tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage. |
1.3.6.1.4.1.318.1.1.1.5.2.40 | upsAdvConfigLowerBypassVoltTolerance | 1 | 1 | Lower tolerance of the bypass voltage that allows transfer to bypass by user. Expressed as percent of nominal voltage. |
1.3.6.1.4.1.318.1.1.1.5.2.41 | upsAdvConfigOutofSyncBypassTransferDelay | 1 | 1 | Configure the time (in milliseconds), indicating the gap in output voltage if an asynchronous transfer to bypass needs to occur. |
1.3.6.1.4.1.318.1.1.1.5.2.43 | upsAdvConfigWarningAlarmDelay | 0 | 0 | Configure the time delay for reporting warning alarms (in seconds). |
1.3.6.1.4.1.318.1.1.1.5.2.45 | upsAdvConfigGreenMode | 0 | 0 | Enable/Disable UPS green mode feature. |
1.3.6.1.4.1.318.1.1.1.5.2.46 | upsAdvConfigLCDLocalLanguage | 0 | 0 | Configure the language setting of the UPS LCD display information. |
1.3.6.1.4.1.318.1.1.1.5.2.47 | upsAdvConfigLCDLockOut | 0 | 0 | Enable/Disable the control function of the UPS via the LCD Display. |
1.3.6.1.4.1.318.1.1.1.5.2.48 | upsAdvConfigChargerRate | 0 | 0 | Change the maximum allowed UPS charge rate on select products where 100% represents the manufacturer's recommended rate. A char… |
1.3.6.1.4.1.318.1.1.1.5.2.49 | upsAdvConfigBatterySelection | 0 | 0 | Configure the installed battery type on select products where VRLA is Valve Regulated Lead Acid type battery and Vented Cell is … |