Set the method to control the humidity in the room.
The two methods are Relative Humidity (RH) or Dew
Point of the selected control sensor air. The dew
point method helps correct for hot spots near the
selected control sensors.
A value of notApplicable indicates that this OID does
not apply to this device due to its configuration.
Parsed from file powernet.mib.txt
Company: None
Module: PowerNet-MIB
Set the method to control the humidity in the room.
The two methods are Relative Humidity (RH) or Dew
Point of the selected control sensor air. The dew
point method helps correct for hot spots near the
selected control sensors.
A value of notApplicable indicates that this OID does
not apply to this device due to its configuration.
Parsed from file PowerNet-MIB.mib
Module: PowerNet-MIB
airFMSysHumCtrlSetting OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), relativeHum (2), dewPoint (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the method to control the humidity in the room. The two methods are Relative Humidity (RH) or Dew Point of the selected control sensor air. The dew point method helps correct for hot spots near the selected control sensors. A value of notApplicable indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysHumidify 5 }
Vendor: American Power Conversion Corp.
Module: PowerNet-MIB
[Automatically extracted from oidview.com]
airFMSysHumCtrlSetting OBJECT-TYPE SYNTAX INTEGER { notApplicable (1), relativeHum (2), dewPoint (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Set the method to control the humidity in the room. The two methods are Relative Humidity (RH) or Dew Point of the selected control sensor air. The dew point method helps correct for hot spots near the selected control sensors. A value of notApplicable indicates that this OID does not apply to this device due to its configuration." ::= { airFMSysHumidify 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.6.5.0 | airFMSysHumCtrlSetting | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.318.1.1.13.1.4.6.1 | airFMSysHumState | 1 | 1 | Set the mode to enabled or disabled. Disabled modes will not operate, and you cannot make changes to their settings while they ar… |
1.3.6.1.4.1.318.1.1.13.1.4.6.2 | airFMSysHumEssFunction | 1 | 1 | Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during no… |
1.3.6.1.4.1.318.1.1.13.1.4.6.3 | airFMSysHumSetpoint | 1 | 1 | The target value for the selected control sensor air for this mode. It must be at least 1.0 % RH below the dehumidification setpo… |
1.3.6.1.4.1.318.1.1.13.1.4.6.4 | airFMSysHumDeadband | 1 | 1 | The humidity range that controls output when the selected control sensor humidity is below the setpoint. At the top of this range… |
1.3.6.1.4.1.318.1.1.13.1.4.6.6 | airFMSysActualHumCtrl | 1 | 1 | The humidity control method the system is using. A value of notApplicable indicates that this OID does not apply to this device d… |
1.3.6.1.4.1.318.1.1.13.1.4.6.7 | airFMSysHumSensBand | 1 | 1 | The percentage of relative humidity below the setpoint at which the humidifier will output at 100% of capacity. Measured in perc… |