Use this field to specify whether all alarms read
from the parameter file should be placed in the
'active' state or the 'inactive' state upon system
initialization.
Selecting 'activateUponInit' (the default) will
activate all alarms read from the parameter file
when the system initializes.
Selecting 'inactiveUponInit' will place all alarms
in the 'inactive' state when the system initializes.
Modifying this value does not affect the present
state of any alarm.
Parsed from file it-rmon-mib.mib.txt
Company: None
Module: ITOUCH-RMON-MIB
Use this field to specify whether all alarms read
from the parameter file should be placed in the
'active' state or the 'inactive' state upon system
initialization.
Selecting 'activateUponInit' (the default) will
activate all alarms read from the parameter file
when the system initializes.
Selecting 'inactiveUponInit' will place all alarms
in the 'inactive' state when the system initializes.
Modifying this value does not affect the present
state of any alarm.
Parsed from file ITOUCHHUB.mib
Module: ITOUCHHUB
xRmonAlarmInitAction OBJECT-TYPE SYNTAX INTEGER { activateUponInit(1), inactiveUponInit(2) } ACCESS read-write STATUS mandatory DESCRIPTION " Use this field to specify whether all alarms read from the parameter file should be placed in the 'active' state or the 'inactive' state upon system initialization. Selecting 'activateUponInit' (the default) will activate all alarms read from the parameter file when the system initializes. Selecting 'inactiveUponInit' will place all alarms in the 'inactive' state when the system initializes. Modifying this value does not affect the present state of any alarm." ::= { xRmonMonitor 11 }
Vendor: MRV Communications, In-Reach Product Division
Module: ITOUCH-RMON-MIB
[Automatically extracted from oidview.com]
xRmonAlarmInitAction OBJECT-TYPE SYNTAX INTEGER { activateUponInit(1), inactiveUponInit(2) } ACCESS read-write STATUS mandatory DESCRIPTION " Use this field to specify whether all alarms read from the parameter file should be placed in the 'active' state or the 'inactive' state upon system initialization. Selecting 'activateUponInit' (the default) will activate all alarms read from the parameter file when the system initializes. Selecting 'inactiveUponInit' will place all alarms in the 'inactive' state when the system initializes. Modifying this value does not affect the present state of any alarm." ::= { xRmonMonitor 11 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.1.11.0 | xRmonAlarmInitAction | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.1.1 | xRmonMonitorRemote | 1 | 1 | Once an alarm is 'completed', monitoring for that variable may be distributed within an enclosure to another processor. Factors … |
1.3.6.1.4.1.33.31.1.2 | xRmonMonitorLocal | 1 | 1 | Once an alarm is 'completed', monitoring for that variable may be distributed within an enclosure to another processor. Factors … |
1.3.6.1.4.1.33.31.1.3 | xRmonLogClear | 1 | 1 | Set this field to 'execute' to delete all RMON log table entries. Setting to 'ready' has no effect. |
1.3.6.1.4.1.33.31.1.4 | xRmonLogTotal | 1 | 1 | This field reports the total number of RMON log entries created since the system was initialized. Clearing the log table does not… |
1.3.6.1.4.1.33.31.1.5 | xRmonLogLastDateTime | 1 | 1 | The local date and time of the system at the time an RMON log entry was last created. |
1.3.6.1.4.1.33.31.1.6 | xRmonTrapType | 1 | 1 | Use this field to specify the type of SNMP trap to generate when an alarm event occurs. The value 'standardFormat' formats the tr… |
1.3.6.1.4.1.33.31.1.7 | xRmonRepeaterManagement | 1 | 1 | This field enables and disables RMON monitoring of certain repeater related variables in the chassis. Set this field to 'enabled'… |
1.3.6.1.4.1.33.31.1.8 | xRmonAlarmActivate | 1 | 1 | Use this field to change the states of all completed alarms to 'active' or 'inactive'. Select 'activateAll' to make all completed… |
1.3.6.1.4.1.33.31.1.9 | xRmonAlarmClear | 1 | 1 | Set this field to 'deleteAll' to delete all alarm table entries and their associated event entries. Setting to 'noAction' has no … |
1.3.6.1.4.1.33.31.1.10 | xRmonAlarmCount | 4 | 8 | None |