Use this field to change the states of all completed
alarms to 'active' or 'inactive'.
Select 'activateAll' to make all completed alarms
not in the 'active' state become 'active' again.
This is useful for alarms whose error states are not
automatically cleared by the system. Alarms whose
error conditions have not cleared will remain in
their current states.
Select 'deactivateAll' to make all completed alarms
that are in the 'active' state become 'inactive'.
This is a convenient way to suppress alarm activity
while making other configuration changes without
actually deleting the alarms.
Alarms which are incomplete (e.g., 'creating' state)
are not affected by these actions.
If you want to alter the state of a single alarm,
modify the table entry for that alarm.
Selecting noAction has no effect.
Parsed from file it-rmon-mib.mib.txt
Company: None
Module: ITOUCH-RMON-MIB
Use this field to change the states of all completed
alarms to 'active' or 'inactive'.
Select 'activateAll' to make all completed alarms
not in the 'active' state become 'active' again.
This is useful for alarms whose error states are not
automatically cleared by the system. Alarms whose
error conditions have not cleared will remain in
their current states.
Select 'deactivateAll' to make all completed alarms
that are in the 'active' state become 'inactive'.
This is a convenient way to suppress alarm activity
while making other configuration changes without
actually deleting the alarms.
Alarms which are incomplete (e.g., 'creating' state)
are not affected by these actions.
If you want to alter the state of a single alarm,
modify the table entry for that alarm.
Selecting noAction has no effect.
Parsed from file ITOUCHHUB.mib
Module: ITOUCHHUB
xRmonAlarmActivate OBJECT-TYPE SYNTAX INTEGER { noAction(1), activateAll(2), deactivateAll(3) } ACCESS read-write STATUS mandatory DESCRIPTION " Use this field to change the states of all completed alarms to 'active' or 'inactive'. Select 'activateAll' to make all completed alarms not in the 'active' state become 'active' again. This is useful for alarms whose error states are not automatically cleared by the system. Alarms whose error conditions have not cleared will remain in their current states. Select 'deactivateAll' to make all completed alarms that are in the 'active' state become 'inactive'. This is a convenient way to suppress alarm activity while making other configuration changes without actually deleting the alarms. Alarms which are incomplete (e.g., 'creating' state) are not affected by these actions. If you want to alter the state of a single alarm, modify the table entry for that alarm. Selecting noAction has no effect." ::= { xRmonMonitor 8 }
Vendor: MRV Communications, In-Reach Product Division
Module: ITOUCH-RMON-MIB
[Automatically extracted from oidview.com]
xRmonAlarmActivate OBJECT-TYPE SYNTAX INTEGER { noAction(1), activateAll(2), deactivateAll(3) } ACCESS read-write STATUS mandatory DESCRIPTION " Use this field to change the states of all completed alarms to 'active' or 'inactive'. Select 'activateAll' to make all completed alarms not in the 'active' state become 'active' again. This is useful for alarms whose error states are not automatically cleared by the system. Alarms whose error conditions have not cleared will remain in their current states. Select 'deactivateAll' to make all completed alarms that are in the 'active' state become 'inactive'. This is a convenient way to suppress alarm activity while making other configuration changes without actually deleting the alarms. Alarms which are incomplete (e.g., 'creating' state) are not affected by these actions. If you want to alter the state of a single alarm, modify the table entry for that alarm. Selecting noAction has no effect." ::= { xRmonMonitor 8 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.1.8.0 | xRmonAlarmActivate | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.1.1 | xRmonMonitorRemote | 1 | 1 | Once an alarm is 'completed', monitoring for that variable may be distributed within an enclosure to another processor. Factors … |
1.3.6.1.4.1.33.31.1.2 | xRmonMonitorLocal | 1 | 1 | Once an alarm is 'completed', monitoring for that variable may be distributed within an enclosure to another processor. Factors … |
1.3.6.1.4.1.33.31.1.3 | xRmonLogClear | 1 | 1 | Set this field to 'execute' to delete all RMON log table entries. Setting to 'ready' has no effect. |
1.3.6.1.4.1.33.31.1.4 | xRmonLogTotal | 1 | 1 | This field reports the total number of RMON log entries created since the system was initialized. Clearing the log table does not… |
1.3.6.1.4.1.33.31.1.5 | xRmonLogLastDateTime | 1 | 1 | The local date and time of the system at the time an RMON log entry was last created. |
1.3.6.1.4.1.33.31.1.6 | xRmonTrapType | 1 | 1 | Use this field to specify the type of SNMP trap to generate when an alarm event occurs. The value 'standardFormat' formats the tr… |
1.3.6.1.4.1.33.31.1.7 | xRmonRepeaterManagement | 1 | 1 | This field enables and disables RMON monitoring of certain repeater related variables in the chassis. Set this field to 'enabled'… |
1.3.6.1.4.1.33.31.1.9 | xRmonAlarmClear | 1 | 1 | Set this field to 'deleteAll' to delete all alarm table entries and their associated event entries. Setting to 'noAction' has no … |
1.3.6.1.4.1.33.31.1.10 | xRmonAlarmCount | 4 | 8 | None |
1.3.6.1.4.1.33.31.1.11 | xRmonAlarmInitAction | 1 | 1 | Use this field to specify whether all alarms read from the parameter file should be placed in the 'active' state or the 'inactive… |