This field shows the value of the alarm variable at
the end of the most recent monitoring interval. If
the alarm sample type is 'changeInValue', it instead
shows the change in value over that interval.
This field is zero any time the alarm is not active,
or when the alarm is a wildcard (that is, a port or
repeater number of 0 was specified for key 2 value).
The value of this field has meaning after the alarm
configuration is complete and monitoring begins.
Parsed from file it-rmon-mib.mib.txt
Company: None
Module: ITOUCH-RMON-MIB
This field shows the value of the alarm variable at
the end of the most recent monitoring interval. If
the alarm sample type is 'changeInValue', it instead
shows the change in value over that interval.
This field is zero any time the alarm is not active,
or when the alarm is a wildcard (that is, a port or
repeater number of 0 was specified for key 2 value).
The value of this field has meaning after the alarm
configuration is complete and monitoring begins.
Parsed from file ITOUCHHUB.mib
Module: ITOUCHHUB
mbAlarmValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " This field shows the value of the alarm variable at the end of the most recent monitoring interval. If the alarm sample type is 'changeInValue', it instead shows the change in value over that interval. This field is zero any time the alarm is not active, or when the alarm is a wildcard (that is, a port or repeater number of 0 was specified for key 2 value). The value of this field has meaning after the alarm configuration is complete and monitoring begins." ::= { xRmonMBConfig 10 }
Vendor: MRV Communications, In-Reach Product Division
Module: ITOUCH-RMON-MIB
[Automatically extracted from oidview.com]
mbAlarmValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION " This field shows the value of the alarm variable at the end of the most recent monitoring interval. If the alarm sample type is 'changeInValue', it instead shows the change in value over that interval. This field is zero any time the alarm is not active, or when the alarm is a wildcard (that is, a port or repeater number of 0 was specified for key 2 value). The value of this field has meaning after the alarm configuration is complete and monitoring begins." ::= { xRmonMBConfig 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.2.1.10.0 | mbAlarmValue | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.2.1.1 | mbAlarmIndex | 1 | 1 | This field can be either the index of an existing alarm (as seen in the alarm summary view) or a new number to create a new alarm… |
1.3.6.1.4.1.33.31.2.1.2 | mbAlarmInterval | 1 | 1 | The interval in seconds over which the variable is sampled and compared with the rising and falling thresholds. If the monitored… |
1.3.6.1.4.1.33.31.2.1.3 | mbAlarmVariable | 1 | 1 | This value shows the SNMP object identifier of the variable being sampled. Only variables that have an SNMP 'SYNTAX' of INTEGER,… |
1.3.6.1.4.1.33.31.2.1.4 | mbAlarmInterpretation | 1 | 1 | Use this field when you want to select an alarm variable without specifying its entire SNMP object identifier. First, modify thi… |
1.3.6.1.4.1.33.31.2.1.5 | mbAlarmKey1Meaning | 1 | 1 | This field describes how its adjacent key value field will be interpreted when building a complete SNMP object identifier for the… |
1.3.6.1.4.1.33.31.2.1.6 | mbAlarmKey1 | 1 | 1 | Specify a value here according the the instructions given in its adjacent prompt field. That prompt explains how this field will… |
1.3.6.1.4.1.33.31.2.1.7 | mbAlarmKey2Meaning | 1 | 1 | This field describes how its adjacent key value field will be interpreted when building a complete SNMP object identifier for the… |
1.3.6.1.4.1.33.31.2.1.8 | mbAlarmKey2 | 1 | 1 | Specify a value here according the the instructions given in its adjacent prompt field. That prompt explains how this field will… |
1.3.6.1.4.1.33.31.2.1.9 | mbAlarmSampleType | 1 | 1 | Use this field to select the method of calculating the value to be compared against the thresholds. When you set this to 'absolut… |
1.3.6.1.4.1.33.31.2.1.11 | mbAlarmRisingThreshold | 1 | 1 | This is the rising threshold value for the alarm. When the current alarm value, specified by the alarm sample type, is greater th… |
1.3.6.1.4.1.33.31.2.1.12 | mbAlarmFallingThreshold | 1 | 1 | This is the falling threshold value for the alarm. When the current alarm value, specified by the alarm sample type, is less than… |
1.3.6.1.4.1.33.31.2.1.13 | mbAlarmRisingEventType | 1 | 1 | Use this field to indicate the type of notification to make when the alarm variable exceeds its rising threshold. The default ac… |
1.3.6.1.4.1.33.31.2.1.14 | mbAlarmFallingEventType | 1 | 1 | Use this field to indicate the type of notification to make when the alarm variable exceeds its falling threshold. The default a… |
1.3.6.1.4.1.33.31.2.1.15 | mbAlarmSummary | 1 | 1 | As you make changes to the to alarm settings, this field is filled with an easily readable summary of the alarm parameters. This… |
1.3.6.1.4.1.33.31.2.1.16 | mbAlarmStatus | 1 | 1 | Describes the current operational state of the alarm and allows you to make limited changes in the state of the alarm for purpose… |