As you make changes to the to alarm settings, this
field is filled with an easily readable summary of
the alarm parameters. This is to make it easy for
you to confirm that monitoring will behave as you
expected once the alarm status is 'active'.
Parsed from file it-rmon-mib.mib.txt
Company: None
Module: ITOUCH-RMON-MIB
As you make changes to the to alarm settings, this
field is filled with an easily readable summary of
the alarm parameters. This is to make it easy for
you to confirm that monitoring will behave as you
expected once the alarm status is 'active'.
Parsed from file ITOUCHHUB.mib
Module: ITOUCHHUB
mbAlarmSummary OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION " As you make changes to the to alarm settings, this field is filled with an easily readable summary of the alarm parameters. This is to make it easy for you to confirm that monitoring will behave as you expected once the alarm status is 'active'." ::= { xRmonMBConfig 15 }
Vendor: MRV Communications, In-Reach Product Division
Module: ITOUCH-RMON-MIB
[Automatically extracted from oidview.com]
mbAlarmSummary OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION " As you make changes to the to alarm settings, this field is filled with an easily readable summary of the alarm parameters. This is to make it easy for you to confirm that monitoring will behave as you expected once the alarm status is 'active'." ::= { xRmonMBConfig 15 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.2.1.15.0 | mbAlarmSummary | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.33.31.2.1.1 | mbAlarmIndex | 1 | 1 | This field can be either the index of an existing alarm (as seen in the alarm summary view) or a new number to create a new alarm… |
1.3.6.1.4.1.33.31.2.1.2 | mbAlarmInterval | 1 | 1 | The interval in seconds over which the variable is sampled and compared with the rising and falling thresholds. If the monitored… |
1.3.6.1.4.1.33.31.2.1.3 | mbAlarmVariable | 1 | 1 | This value shows the SNMP object identifier of the variable being sampled. Only variables that have an SNMP 'SYNTAX' of INTEGER,… |
1.3.6.1.4.1.33.31.2.1.4 | mbAlarmInterpretation | 1 | 1 | Use this field when you want to select an alarm variable without specifying its entire SNMP object identifier. First, modify thi… |
1.3.6.1.4.1.33.31.2.1.5 | mbAlarmKey1Meaning | 1 | 1 | This field describes how its adjacent key value field will be interpreted when building a complete SNMP object identifier for the… |
1.3.6.1.4.1.33.31.2.1.6 | mbAlarmKey1 | 1 | 1 | Specify a value here according the the instructions given in its adjacent prompt field. That prompt explains how this field will… |
1.3.6.1.4.1.33.31.2.1.7 | mbAlarmKey2Meaning | 1 | 1 | This field describes how its adjacent key value field will be interpreted when building a complete SNMP object identifier for the… |
1.3.6.1.4.1.33.31.2.1.8 | mbAlarmKey2 | 1 | 1 | Specify a value here according the the instructions given in its adjacent prompt field. That prompt explains how this field will… |
1.3.6.1.4.1.33.31.2.1.9 | mbAlarmSampleType | 1 | 1 | Use this field to select the method of calculating the value to be compared against the thresholds. When you set this to 'absolut… |
1.3.6.1.4.1.33.31.2.1.10 | mbAlarmValue | 1 | 1 | This field shows the value of the alarm variable at the end of the most recent monitoring interval. If the alarm sample type is … |
1.3.6.1.4.1.33.31.2.1.11 | mbAlarmRisingThreshold | 1 | 1 | This is the rising threshold value for the alarm. When the current alarm value, specified by the alarm sample type, is greater th… |
1.3.6.1.4.1.33.31.2.1.12 | mbAlarmFallingThreshold | 1 | 1 | This is the falling threshold value for the alarm. When the current alarm value, specified by the alarm sample type, is less than… |
1.3.6.1.4.1.33.31.2.1.13 | mbAlarmRisingEventType | 1 | 1 | Use this field to indicate the type of notification to make when the alarm variable exceeds its rising threshold. The default ac… |
1.3.6.1.4.1.33.31.2.1.14 | mbAlarmFallingEventType | 1 | 1 | Use this field to indicate the type of notification to make when the alarm variable exceeds its falling threshold. The default a… |
1.3.6.1.4.1.33.31.2.1.16 | mbAlarmStatus | 1 | 1 | Describes the current operational state of the alarm and allows you to make limited changes in the state of the alarm for purpose… |