Reference record for OID 1.3.6.1.4.1.33.31.2.1.14


parent
1.3.6.1.4.1.33.31.2.1 (xRmonMBConfig)
node code
14
node name
mbAlarmFallingEventType
dot oid
1.3.6.1.4.1.33.31.2.1.14
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xyplex(33) powerAlarmFuseBankA(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) xyplex(33) xRmon(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) iTouch(33) powerAlarmFuseBankA(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) iTouch(33) xRmon(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) xyplex(33) powerAlarmFuseBankA(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) xyplex(33) xRmon(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) iTouch(33) powerAlarmFuseBankA(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) iTouch(33) xRmon(31) xRmonMB(2) xRmonMBConfig(1) mbAlarmFallingEventType(14)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/xyplex/powerAlarmFuseBankA/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • /iso/identified-organization/dod/internet/private/enterprise/xyplex/xRmon/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/iTouch/powerAlarmFuseBankA/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • /iso/org/dod/internet/private/enterprise/iTouch/xRmon/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • /iso/org/dod/internet/private/enterprises/xyplex/powerAlarmFuseBankA/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • /iso/org/dod/internet/private/enterprises/xyplex/xRmon/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/iTouch/powerAlarmFuseBankA/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • /iso/iso-identified-organization/dod/internet/private/enterprises/iTouch/xRmon/xRmonMB/xRmonMBConfig/mbAlarmFallingEventType
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/33/31/2/1/14

    Description by mibdepot

    Use this field to indicate the type of notification
    to make when the alarm variable exceeds its falling
    threshold. The default action is to generate both
    a log entry and a trap.

    Set this field to noAction to suppress notification
    of falling threshold events.

    Set this field to logOnly to generate an RMON alarm
    log entry. These log entries may be viewed through
    the RMON alarm log view.

    Set this field to trapOnly to generate an SNMP trap.
    Refer to the RMON alarm summary to specify whether
    traps are generated in standard RMON format or in
    iTouch format.

    Choosing logAndTrap invokes both these actions.

    You may not modify this field once the alarm is
    completed (see alarm status field).

    Parsed from file it-rmon-mib.mib.txt
    Company: None
    Module: ITOUCH-RMON-MIB

    Description by circitor

    Use this field to indicate the type of notification
    to make when the alarm variable exceeds its falling
    threshold. The default action is to generate both
    a log entry and a trap.

    Set this field to noAction to suppress notification
    of falling threshold events.

    Set this field to logOnly to generate an RMON alarm
    log entry. These log entries may be viewed through
    the RMON alarm log view.

    Set this field to trapOnly to generate an SNMP trap.
    Refer to the RMON alarm summary to specify whether
    traps are generated in standard RMON format or in
    iTouch format.

    Choosing logAndTrap invokes both these actions.

    You may not modify this field once the alarm is
    completed (see alarm status field).

    Parsed from file ITOUCHHUB.mib
    Module: ITOUCHHUB

    Information by mibdepot

    mbAlarmFallingEventType OBJECT-TYPE SYNTAX INTEGER { noAction(1), logOnly(2), trapOnly(3), logAndTrap(4) } ACCESS read-write STATUS mandatory DESCRIPTION " Use this field to indicate the type of notification to make when the alarm variable exceeds its falling threshold. The default action is to generate both a log entry and a trap. Set this field to noAction to suppress notification of falling threshold events. Set this field to logOnly to generate an RMON alarm log entry. These log entries may be viewed through the RMON alarm log view. Set this field to trapOnly to generate an SNMP trap. Refer to the RMON alarm summary to specify whether traps are generated in standard RMON format or in iTouch format. Choosing logAndTrap invokes both these actions. You may not modify this field once the alarm is completed (see alarm status field)." DEFVAL { logAndTrap } ::= { xRmonMBConfig 14 }

    Information by oid_info

    Vendor: MRV Communications, In-Reach Product Division
    Module: ITOUCH-RMON-MIB

    [Automatically extracted from oidview.com]

    Information by circitor

    mbAlarmFallingEventType OBJECT-TYPE SYNTAX INTEGER { noAction(1), logOnly(2), trapOnly(3), logAndTrap(4) } ACCESS read-write STATUS mandatory DESCRIPTION " Use this field to indicate the type of notification to make when the alarm variable exceeds its falling threshold. The default action is to generate both a log entry and a trap. Set this field to noAction to suppress notification of falling threshold events. Set this field to logOnly to generate an RMON alarm log entry. These log entries may be viewed through the RMON alarm log view. Set this field to trapOnly to generate an SNMP trap. Refer to the RMON alarm summary to specify whether traps are generated in standard RMON format or in iTouch format. Choosing logAndTrap invokes both these actions. You may not modify this field once the alarm is completed (see alarm status field)." DEFVAL { logAndTrap } ::= { xRmonMBConfig 14 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.33)

    Szydlo Faith

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.33.31.2.1.14.0 mbAlarmFallingEventType 0 0 None

    Brothers (15)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.33.31.2.1.1 mbAlarmIndex 1 1 This field can be either the index of an existing
    alarm (as seen in the alarm summary view) or a new
    number to create a new alarm…
    1.3.6.1.4.1.33.31.2.1.2 mbAlarmInterval 1 1 The interval in seconds over which the variable is
    sampled and compared with the rising and falling
    thresholds. If the monitored…
    1.3.6.1.4.1.33.31.2.1.3 mbAlarmVariable 1 1 This value shows the SNMP object identifier of the
    variable being sampled. Only variables that have an
    SNMP 'SYNTAX' of INTEGER,…
    1.3.6.1.4.1.33.31.2.1.4 mbAlarmInterpretation 1 1 Use this field when you want to select an alarm
    variable without specifying its entire SNMP object
    identifier. First, modify thi…
    1.3.6.1.4.1.33.31.2.1.5 mbAlarmKey1Meaning 1 1 This field describes how its adjacent key value
    field will be interpreted when building a complete
    SNMP object identifier for the…
    1.3.6.1.4.1.33.31.2.1.6 mbAlarmKey1 1 1 Specify a value here according the the instructions
    given in its adjacent prompt field. That prompt
    explains how this field will…
    1.3.6.1.4.1.33.31.2.1.7 mbAlarmKey2Meaning 1 1 This field describes how its adjacent key value
    field will be interpreted when building a complete
    SNMP object identifier for the…
    1.3.6.1.4.1.33.31.2.1.8 mbAlarmKey2 1 1 Specify a value here according the the instructions
    given in its adjacent prompt field. That prompt
    explains how this field will…
    1.3.6.1.4.1.33.31.2.1.9 mbAlarmSampleType 1 1 Use this field to select the method of calculating
    the value to be compared against the thresholds.

    When you set this to 'absolut…
    1.3.6.1.4.1.33.31.2.1.10 mbAlarmValue 1 1 This field shows the value of the alarm variable at
    the end of the most recent monitoring interval. If
    the alarm sample type is …
    1.3.6.1.4.1.33.31.2.1.11 mbAlarmRisingThreshold 1 1 This is the rising threshold value for the alarm.

    When the current alarm value, specified by the alarm
    sample type, is greater th…
    1.3.6.1.4.1.33.31.2.1.12 mbAlarmFallingThreshold 1 1 This is the falling threshold value for the alarm.

    When the current alarm value, specified by the alarm
    sample type, is less than…
    1.3.6.1.4.1.33.31.2.1.13 mbAlarmRisingEventType 1 1 Use this field to indicate the type of notification
    to make when the alarm variable exceeds its rising
    threshold. The default ac…
    1.3.6.1.4.1.33.31.2.1.15 mbAlarmSummary 1 1 As you make changes to the to alarm settings, this
    field is filled with an easily readable summary of
    the alarm parameters. This…
    1.3.6.1.4.1.33.31.2.1.16 mbAlarmStatus 1 1 Describes the current operational state of the
    alarm and allows you to make limited changes in
    the state of the alarm for purpose…