Managment access to Multi-Flex Server chassis.
There is still some question where under the products tree this
belongs the chassisManagement tree would be logical *if* there
is possibility of either the Multi-Flex Server chassis will be allowed
a 3rd party CMM, or if the CMM may be put in a 3rd party
chassis. It appears that initially that neither is the case
and that Multi-Flex Server will remain solely an SMB unit. Thus, it
may be placed by itself under the smb tree
Parsed from file INTELCORPORATION-MULTI-FLEX-SERVER-MIB.mib
Module: INTELCORPORATION-MULTI-FLEX-SERVER-MIB
Vendor: Intel Corporation
Module: INTELCORPORATION-MULTI-FLEX-SERVER-MIB
[Automatically extracted from oidview.com]
multiFlexServerMibModule MODULE-IDENTITY LAST-UPDATED "200708211700Z" ORGANIZATION "Intel Corporation" CONTACT-INFO "Brian Kurle Intel Corporation JF5-2-C3 Tel: 503-712-5032 E-Mail: [email protected]" DESCRIPTION "Managment access to Multi-Flex Server chassis. There is still some question where under the products tree this belongs the chassisManagement tree would be logical *if* there is possibility of either the Multi-Flex Server chassis will be allowed a 3rd party CMM, or if the CMM may be put in a 3rd party chassis. It appears that initially that neither is the case and that Multi-Flex Server will remain solely an SMB unit. Thus, it may be placed by itself under the smb tree" REVISION "200708211700Z" DESCRIPTION "Renamed eventPolicyId to eventId" REVISION "200708161330Z" DESCRIPTION "Reordered Revision to reverse chronological as some browsers choke, cleaned up some other simple nit-picky errors Added eventPolicyId to the notification group " REVISION "200707161130Z" DESCRIPTION "Dropped chassisBmcFirmwareVersion as it is really the same information as the the CMM, which manages the chassis." REVISION "200706072030Z" DESCRIPTION "Added the IdromBinary16 to represent the asset tag, part number, and serial number fields within the IDROM fields." REVISION "200706071330Z" DESCRIPTION "Corrected maximum/nominal IDROM parameters and comments" REVISION "200705301330Z" DESCRIPTION "Fixed location of the chassisNotificationGroup (previously typo'd to the wrong tree)" REVISION "200705301030Z" DESCRIPTION "Added initial generic notification/trap type" REVISION "200704091030Z" DESCRIPTION "Added overlooked BMC Version information" REVISION "200703121830Z" DESCRIPTION "Moved FirmwareBundleId from chassis to CMM Tree. Data now complies with IDROM (DID/DSD) information. Renumbered / reorganized accordingly" REVISION "200703061030Z" DESCRIPTION "Removed chassisVersion & chassisUpgradeFirmware at architects' request Renumbered/resequenced entries accordingly" REVISION "200702221700Z" DESCRIPTION "Renamed MIB file and updated internal relevance to formal product name Multi-Flex Server" REVISION "200611011000Z" DESCRIPTION "Changed 'theChassis' to 'chassis'" REVISION "200609291529Z" DESCRIPTION "Rearranged the Promise MIB information and morphed it into our format. Removed either superfluous or undesired objects." REVISION "200609281732Z" DESCRIPTION "Removed codename references and 'global prefixing.' Created and moved Textual Conventions to own module." REVISION "200609010624Z" DESCRIPTION "Parceled out the sub components to their own modules." ::= { regModule 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.19.1.1.1.1 | multiFlexServerRegModule | 0 | 0 | Registry module definitions for entire Multi-Flex Server MIB system |
1.3.6.1.4.1.343.2.19.1.1.1.2 | multiFlexServerTcModule | 0 | 0 | Textual Conventions used within INTELCORPORATION-MULTI-FLEX-SERVER-*MIB |
1.3.6.1.4.1.343.2.19.1.1.1.11 | multiFlexServerCmmMibModule | 0 | 0 | CMM Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.12 | multiFlexServerBladesMibModule | 0 | 0 | Blade Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.13 | multiFlexServerSwitchMibModule | 0 | 0 | Switch Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.14 | multiFlexServerScmMibModule | 0 | 0 | Controller Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.15 | multiFlexServerDrivesMibModule | 0 | 0 | Shared Disks Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.16 | multiFlexServerFanMibModule | 0 | 0 | Fan Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.17 | multiFlexServerPwrMibModule | 0 | 0 | Power Supply Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.18 | multiFlexServerStorageMibModule | 0 | 0 | Storage Module of the Multi-Flex Server |