Fan Module of the Multi-Flex Server
Parsed from file INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB.mib
Module: INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB
Vendor: Intel Corporation
Module: INTELCORPORATION-MULTI-FLEX-SERVER-FAN-MIB
[Automatically extracted from oidview.com]
multiFlexServerFanMibModule MODULE-IDENTITY LAST-UPDATED "200708161300Z" ORGANIZATION "Intel Corporation" CONTACT-INFO "Brian Kurle Intel Corporation JF5-2-C3 Tel: 503-712-5032 E-Mail: [email protected]" DESCRIPTION "Fan Module of the Multi-Flex Server" REVISION "200708161300Z" DESCRIPTION "Corrected a few entries that were marked as read-write when they should have been read-only" REVISION "200706190030Z" DESCRIPTION "Finalized the Version information for the MIB based on information available/used by the rest of the system (e.g., the GUI/fwupdate) Dropped fanFruBmcFirmwareVersion. Added fanFruOpCodeVersion & fanFruBootBlockVersion." REVISION "200706072030Z" DESCRIPTION "Added the IdromBinary16 to represent the asset tag, part number, and serial number fields within the IDROM fields." REVISION "200706071330Z" DESCRIPTION "Corrected maximum/nominal IDROM parameters and comments" REVISION "200705301900Z" DESCRIPTION "Moved Presence column to just after the index within fanFruTable" REVISION "200705211700Z" DESCRIPTION "Added notApplicable and unknown states to various entries" REVISION "200704251700Z" DESCRIPTION "Dropped fanFruNumOfAxis & fanFruFansPerAxis from fanFruTable" REVISION "200704241630Z" DESCRIPTION "Dropped fanRpmSetting & fanCoefficient from the fanTable (minor column renumbering)" REVISION "200704181905Z" DESCRIPTION "Moved the trees and chassis nodes around to accomodate the unique power supply characteristics" REVISION "200704091030Z" DESCRIPTION "Renamed fanFruFirmwareVersion to fanFruBmcFirmwareVersion to be consistent in naming with the other subsystems" REVISION "200704021030Z" DESCRIPTION "Updated comments to tag fields that may be either statically returned, or that may potentially be removed" REVISION "200703141700Z" DESCRIPTION "Added fanFruNumOfFans, fanFruNumOfAxis, fanFruFansPerAxis, & fanFruInletTemperature to fanFruTable Dropped fanCoolingStatus & fanCoolingSpeed from fanFruTable Added new (replaced) doubly indexed fanTable (indices being the fan FRU and the individual fan within the fan FRU) Renumbered / reorganized accordingly" REVISION "200703131500Z" DESCRIPTION "fanFruTable data now complies with IDROM (DID/DSD) information. Renumbered / reorganized accordingly" REVISION "200703061030Z" DESCRIPTION "Changed Mask representation from an Opaque to a DisplayString at the request of the architects such that it now is an ASCII representation of bit string reflecting the presence with the left most 'bit' being bit 1 and max* bits being represented." REVISION "200702221700Z" DESCRIPTION "Renamed MIB file and updated internal relevance to formal product name Multi-Flex Server" REVISION "200611071130Z" DESCRIPTION "Consolodated use of Presence datatype and changed 'chassis' to 'chassis'" REVISION "200610020629Z" DESCRIPTION "Partitioned off and created as it's own module" ::= { regModule 16 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.343.2.19.1.1.1.1 | multiFlexServerRegModule | 0 | 0 | Registry module definitions for entire Multi-Flex Server MIB system |
1.3.6.1.4.1.343.2.19.1.1.1.2 | multiFlexServerTcModule | 0 | 0 | Textual Conventions used within INTELCORPORATION-MULTI-FLEX-SERVER-*MIB |
1.3.6.1.4.1.343.2.19.1.1.1.10 | multiFlexServerMibModule | 0 | 0 | Managment access to Multi-Flex Server chassis. There is still some question where under the products tree this belongs the chassiā¦ |
1.3.6.1.4.1.343.2.19.1.1.1.11 | multiFlexServerCmmMibModule | 0 | 0 | CMM Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.12 | multiFlexServerBladesMibModule | 0 | 0 | Blade Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.13 | multiFlexServerSwitchMibModule | 0 | 0 | Switch Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.14 | multiFlexServerScmMibModule | 0 | 0 | Controller Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.15 | multiFlexServerDrivesMibModule | 0 | 0 | Shared Disks Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.17 | multiFlexServerPwrMibModule | 0 | 0 | Power Supply Module of the Multi-Flex Server |
1.3.6.1.4.1.343.2.19.1.1.1.18 | multiFlexServerStorageMibModule | 0 | 0 | Storage Module of the Multi-Flex Server |